Manifold Optimization for High-Accuracy Spatial Location Estimation Using Ultrasound Waves

被引:4
|
作者
AlSharif, Mohammed H. [1 ]
Douik, Ahmed [2 ]
Ahmed, Mohanad [1 ]
Al-Naffouri, Tareq Y. [1 ]
Hassibi, Babak [2 ]
机构
[1] King Abdullah Univ Sci & Technol, Div Comp Elect & Math Sci & Engn, Thuwal 239556900, Saudi Arabia
[2] CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
关键词
Spatial location estimation; ultrasound waves; fixed transmitters geometry; riemannian manifold optimization; RANGE ESTIMATION; SYSTEMS; ALGORITHM; RADAR;
D O I
10.1109/TSP.2021.3109792
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports the design of a high-accuracy spatial location estimation method using ultrasound waves by exploiting the fixed geometry of the transmitters. Assuming an isosceles triangle antenna configuration, where three antennas are placed as the vertices of an isosceles triangle, the spatial location problem can be formulated as a non-convex optimization problem whose interior is shown to admit a Riemannian manifold structure. Our investigation of the geometry of the newly introduced manifold (i.e., the manifold of all isosceles triangles in R-3) enables the design of highly efficient optimization algorithms. Simulations are presented to compare the performance of the proposed approach with popular methods from the literature. The results suggest that the proposed Riemannian-based methods outperform the state-ofthe-art methods. Furthermore, the proposed Riemannian methods require much less computation time compared to popular generic non-convex approaches.
引用
收藏
页码:5078 / 5093
页数:16
相关论文
共 50 条
  • [1] Toward High-Accuracy Estimation of Partial Discharge Location
    Al-Masri, Wasim M. F.
    Abdel-Hafez, Mamoun F.
    El-Hag, Ayman H.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (09) : 2145 - 2153
  • [2] High-Accuracy Reference-Free Ultrasonic Location Estimation
    Saad, M. M.
    Bleakley, Chris J.
    Ballal, T.
    Dobson, Simon
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (06) : 1561 - 1570
  • [3] Dynamic fracture analysis using a high-accuracy manifold element modelling scheme
    Li, Gen
    Wang, Kai
    Tang, Chunan
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2022, 236
  • [4] High-accuracy Baseline Estimation using Differential NavIC and GPS
    Althaf, A.
    Hablani, Hari
    PROCEEDINGS OF THE 2020 INTERNATIONAL TECHNICAL MEETING OF THE INSTITUTE OF NAVIGATION, 2020, : 454 - 467
  • [5] High-Speed and High-accuracy Scene Flow Estimation using Kinect
    Sato, Kyosuke
    Wu, Haiyuan
    Chen, Qian
    17TH INTERNATIONAL CONFERENCE IN KNOWLEDGE BASED AND INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS - KES2013, 2013, 22 : 945 - 953
  • [6] High-accuracy device for the spatial orientation of objects
    Zhukov, Yu. P.
    Lovchi, I. L.
    Chudakov, Yu. I.
    Shevtsov, I. V.
    JOURNAL OF OPTICAL TECHNOLOGY, 2009, 76 (09) : 568 - 569
  • [7] A High-accuracy Parameter Estimation PSO Algorithm
    Yin, Yan-chao
    Sun, Lin-fu
    Han, Min
    2008 INTERNATIONAL CONFERENCE ON EMBEDDED SOFTWARE AND SYSTEMS SYMPOSIA, PROCEEDINGS, 2008, : 7 - 12
  • [8] Design of high-accuracy multiple flyby trajectories using constrained optimization
    Byrnes, DV
    Bright, LE
    ASTRODYNAMICS 1995, 1996, 90 : 121 - 133
  • [9] High-Accuracy Simulation of Rayleigh Waves Using Fractional Viscoelastic Wave Equation
    Wang, Yinfeng
    Lu, Jilong
    Shi, Ying
    Wang, Ning
    Han, Liguo
    FRACTAL AND FRACTIONAL, 2023, 7 (12)
  • [10] Ultrasound imaging with flexible transducers based on real-time and high-accuracy shape estimation
    Gao, Xue
    Huang, Lihong
    Huang, Peng
    Wang, Yuanyuan
    Guo, Yi
    ULTRASONICS, 2025, 148