ECG Denoising Method Based on an Improved VMD Algorithm

被引:24
|
作者
Li, Chengjun [1 ]
Wu, Yacen [2 ]
Lin, Haijun [1 ]
Li, Jianmin [1 ]
Zhang, Fu [1 ]
Yang, Yuxiang [1 ]
机构
[1] Hunan Normal Univ, Elect Engn Dept, Changsha 410081, Hunan, Peoples R China
[2] Hunan Normal Univ, Hunan Prov Peoples Hosp, Affiliated Hosp 1, Changsha 410005, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Adaptive particle swarm optimization (APSO); decomposition layers K; denoising; electrocardiogram (ECG); penalty factor alpha; variational mode decomposition (VMD); VARIATIONAL MODE DECOMPOSITION; EXTRACTION; SPECTRUM; SIGNALS; FILTER;
D O I
10.1109/JSEN.2022.3214239
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrocardiogram (ECG) acquisition is easily contaminated by interferences, and denoising is the most important task in ECG detection. The variational mode decomposition (VMD) algorithm is widely used in ECG denoising, which can overcome mode aliasing between intrinsic mode function (IMF) components that existed in the traditional empirical mode decomposition (EMD) algorithm, but the mode decomposition number ${K}$ and penalty factor $\alpha $ in VMD must be optimized to obtain the best signal decomposition accuracy. This article proposes an improved VMD denoising algorithm that overcomes the shortcomings of slow parameter selection and poor generalization in the traditional VMD algorithm. The algorithm presented first adopts the EMD algorithm to remove the low-frequency baseline drift noise and then employs the adaptive particle swarm optimization (APSO) algorithm to optimize the parameter pair (K, alpha) for VMD. To validate the denoising performance of the improved VMD algorithm, the No. 103 record from the Massachusetts Institute of Technology (MIT) arrhythmia database is first selected as the pure ECG signal, then both 20-dB Gaussian white noises and 0.3-Hz baseline drift are added to simulate the noisy ECG signal. Second, the ECG signals of nine subjects are collected by a customized ECG detection platform based on AD8232 and ADALM1000. The ECG denoising results in simulation and actual experiments show that the improved VMD algorithm achieves the highest signal-to-noise ratio (SNR), correlation coefficient (CC), and minimum mean square error (MSE) compared with the traditional EMD and VMD algorithms, which demonstrates that the proposed denoising algorithm has stronger denoising ability and better retains morphological characteristics of the original ECG signals.
引用
收藏
页码:22725 / 22733
页数:9
相关论文
共 50 条
  • [1] ECG signals Denoising Method Based on Improved Wavelet Threshold Algorithm
    Zhang Lin
    Lin Jia-lun
    Li Xiao-ling
    Wang Wei-quan
    PROCEEDINGS OF 2016 IEEE ADVANCED INFORMATION MANAGEMENT, COMMUNICATES, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IMCEC 2016), 2016, : 1779 - 1784
  • [2] ECG signal denoising based on improved MP algorithm
    A-Ying, Wei
    Yin-Jing, Guo
    Xue-Zhen, Cheng
    International Journal of Signal Processing, Image Processing and Pattern Recognition, 2015, 8 (11) : 329 - 338
  • [3] Denoising method of rock acoustic emission signal based on improved VMD
    Cheng, Tiedong
    Zhang, Zhizhao
    Yi, Qiwen
    Yin, Baoyong
    Yuan, Haiping
    Journal of Mining and Strata Control Engineering, 2022, 4 (02)
  • [4] Study on VMD decomposition and denoising of spectral signals based on improved CPO algorithm
    Qinggao Zheng
    Da Qiu
    Junyi Chen
    Jianqiang Zhang
    Hang Gao
    Yang Long
    Song Liu
    Tingting Zhang
    Shiqiang Chen
    Signal, Image and Video Processing, 2025, 19 (4)
  • [5] Research on the Method of ECG Denoising Based on Improved Wavelet Packet
    Gang, Shi
    Liang, Rong
    Gao Yuhan
    2015 IEEE INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2015, : 1425 - 1428
  • [6] A Denoising Method of Partial Discharge Signal Based on Improved SVD-VMD
    Lei, Zhipeng
    Wang, Feiyu
    Li, Chuanyang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (05) : 2107 - 2116
  • [7] ECG denoising based on MP algorithm
    Wei A-ying
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING II, PTS 1-3, 2013, 433-435 : 510 - 513
  • [8] Improved NLMS-based adaptive denoising method for ECG signals
    Wang, Fengsui
    Wang, Qisheng
    Liu, Furong
    Chen, Jingang
    Fu, Linjun
    Zhao, Fa
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (02) : 305 - 316
  • [9] A Method of Denoising ECG Signals Based on Improved Threshold and Modulus Maxima
    Qian, Ying
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 4011 - 4016
  • [10] Sea clutter hybrid denoising algorithm based on VMD
    Sun Jiang
    Xing Hongyan
    Wu Jiajia
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 551 - 558