Design of Performance Test System and Analysis of Temperature Dependence for Space-Borne Array CCD

被引:4
|
作者
Yao Pingping [1 ,2 ]
Xu Sunlong [1 ,2 ]
Tu Bihai [1 ,2 ]
Yu Xinyu [1 ,2 ]
Cui Shanshan [1 ,2 ]
Luo Donggen [1 ,2 ]
Hong Jin [1 ,2 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Anhui, Peoples R China
[2] Chinese Acad Sci, Key Lab Opt Calibrat & Characterizat, Hefei 230031, Anhui, Peoples R China
来源
关键词
measurement; polarization imager; charge coupled device; electro-optical performance; temperature control; thermoelectric cooler;
D O I
10.3788/CJL202047.0910001
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In response to the demand for the photoelectric performance evaluation of multi-angle polarization imaging detectors, a universal testing system for photoelectric performance parameters of image sensors is developed herein, and a Peltier effect-based thermoelectric cooler and low-temperature cycler are combined to control the temperature of the detector. Experimental results show that the light source stability of the integrating sphere is 0.036% , the uniformity of illuminance is >= 99. 3% , the cooling rate of the detector refrigeration system is approximately 2.2 degrees C / min, and the temperature control accuracy is better than +/- 0.15 degrees C, and the temperature is - 10-25 degrees C . For the measurement of key performance parameters such as quantum efficiency, photo response non-uniformity, dark current, full-well charge, and optical response nonlinearity within the operating temperature range, the photo response non-uniformity of the multi-angle polarization imaging detector at different wavelengths is better than 3 degrees C, The optical response nonlinearity is better than 1% , the dark current increases by 1.25 times when the operating temperature from 0 degrees C to 9 degrees C , and the quantum efficiency in the near-infrared band changes by 3.58 percentage. The performance evaluation of the detector guarantees the test performance and calibration requirements of the multi-angle polarization imaging detector.
引用
收藏
页数:10
相关论文
共 21 条
  • [1] ESO's new CCD testbench
    Amico, P
    Bohm, T
    [J]. EXPERIMENTAL ASTRONOMY, 1998, 8 (01) : 1 - 8
  • [2] [Anonymous], 2018, ACTA OPTICA SINICA
  • [3] Cheng Wan-sheng, 2008, Optics and Precision Engineering, V16, P314
  • [4] Cui Shanshan, 2015, Infrared and Laser Engineering, V44, P3397
  • [5] European machine vision association, 2016, EMVA128831A
  • [6] [范慧敏 Fan Huimin], 2018, [大气与环境光学学报, Journal of Atmospheric and Environmental Optics], V13, P233
  • [7] Groom D. E, 2006, SPIE, V6068, P101
  • [8] Li X J, 2014, METHOD RES SYSTEM DE
  • [9] Liu H Y, 2014, ACTA OPTICAL SINICA, V34
  • [10] Liu HY, 2014, ACTA OPT SIN, V34