Normal adrenal gland: In vivo observations, and high-resolution in vitro chemical shift MR imaging-histologic correlation

被引:7
|
作者
Mitchell, DG
Nascimento, AB
Alam, F
Grasel, RP
Holland, G
O'Hara, BJ
机构
[1] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Dept Pathol, Philadelphia, PA 19107 USA
[3] Thomas Jefferson Univ, Dept Pathol Anat & Cell Biol, Philadelphia, PA 19107 USA
[4] Univ Fed Parana, Serv Radiol, BR-80060000 Curitiba, Parana, Brazil
[5] Pulse Diagnost & Res Ctr, Kolkata, W Bengal, India
[6] Hosp Santa Isabel & Clin Ecomax, Serv Radiol, BR-89010600 Blumenau, SC, Brazil
关键词
adrenal gland; MR; magnetic resonance (MR); chemical shift; high resolution;
D O I
10.1016/S1076-6332(03)80188-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to determine whether adrenal cortical lipid affects signal intensity on magnetic resonance (MR) images and to evaluate contrast between cortex and medulla. Materials and Methods. From their clinical database, the authors selected 37 MR imaging studies of patients with adrenal adenomas. Two independent readers compared in-phase and fat-suppressed T1-weighted images, looking for visible lipid-induced signal intensity loss in the adrenal gland. Six adrenal gland specimens obtained after radical nephrectomy were also studied with high-resolution MR imaging, including in-phase, opposed-phase. and fat-suppressed T1-weighted images, and T2-weighted images. Adjacent histologic sections were stained with oil red 0 for neutral fats and with hematoxylin-eosin, and they were also viewed with polarization light microscopy. The relative amount of lipid was graded as mild, moderate, or intense, and the appearance of the cortex and medulla was compared with that on the MR images. Results. On the 37 clinical MR studies, there was no visible signal intensity loss within the limbs of the ipsilateral adrenal glands. T2-weighted images of the adrenal specimens showed a thin high-intensity band, corresponding to the appearance of medulla on histologic slices. This could not be seen on any of the T1-weighted images. Region-of-interest measurements were nearly identical for in-phase and opposed-phase images. Histologic analysis showed abundant cortical lipid. Conclusion. Adrenal corticomedullary contrast can be depicted on high-resolution T2-weighted images but not on any T1-weighted images. There is abundant cortical lipid in adrenal specimens, but comparison of in-phase with opposed-phase MR images does not depict it.
引用
收藏
页码:430 / 436
页数:7
相关论文
共 50 条
  • [1] The normal adrenal cortex: High-resolution chemical shift MR imaging, with histologic correlation
    Mitchell, DG
    Nascimento, AB
    Alam, F
    Grasel, RP
    Holland, GA
    O'Hara, BJ
    RADIOLOGY, 2001, 221 : 315 - 316
  • [2] HIGH-RESOLUTION BREAST MR-IMAGING - CORRELATION WITH BREAST HISTOLOGIC CHARACTERISTICS
    HENDRICK, RE
    HOLLAND, A
    RUSS, PD
    JIN, H
    SISNEY, GA
    RADIOLOGY, 1995, 197 : 288 - 288
  • [3] CT AND MR LYMPHOGRAPHY OF NORMAL AND CANCEROUS POPLITEAL NODES - IMAGING-HISTOLOGIC CORRELATION AND ROC ANALYSIS
    WOLF, GL
    GAZELLE, GS
    JIANG, DY
    TRUBETSKOY, VS
    HALPERN, EF
    RADIOLOGY, 1995, 197 : 136 - 136
  • [4] Normal fetal pituitary gland: Study on MR imaging and histologic correlation
    Ma, L
    Gao, YA
    Gao, YG
    Liang, Y
    Luo, Y
    RADIOLOGY, 1998, 209P : 348 - 348
  • [5] Chemical Shift MR Imaging of the Adrenal Gland: Principles, Pitfalls, and Applications
    Adam, Sharon Z.
    Nikolaidis, Paul
    Horowitz, Jeanne M.
    Gabriel, Helena
    Hammond, Nancy A.
    Patel, Tanvi
    Yaghmai, Vahid
    Miller, Frank H.
    RADIOGRAPHICS, 2016, 36 (02) : 414 - 432
  • [6] Localization and impact of PFOA in vivo and in vitro by high-resolution chemical imaging
    Stoffels, C.
    Robert, H.
    Leveque, M.
    Oliviero, F.
    Lakhal, L.
    Wirtz, T.
    Mercier-Bonin, M.
    Gutleb, A. C.
    Audinot, J. -N.
    TOXICOLOGY LETTERS, 2021, 350 : S187 - S187
  • [7] Arterial imaging: Comparison of high resolution US and MR imaging with histologic correlation
    Martin, AJ
    Ryan, LK
    Gotlieb, AI
    Henkelman, RM
    Foster, FS
    RADIOGRAPHICS, 1997, 17 (01) : 189 - 202
  • [8] High-resolution in vivo MR imaging of carotid atheroma
    Coulden, RA
    Graves, MJ
    Sonnex, E
    Flick, H
    RADIOLOGY, 2000, 217 : 180 - 181
  • [9] HIGH-RESOLUTION MR IMAGING OF THE NORMAL ROTATOR CUFF
    MIDDLETON, WD
    KNEELAND, JB
    CARRERA, GF
    CATES, JD
    KELLMAN, GM
    CAMPAGNA, NG
    JESMANOWICZ, A
    FRONCISZ, W
    HYDE, JS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (03) : 559 - 564
  • [10] HIGH-RESOLUTION MR GADOLINIUM ENHANCED CHEMICAL-SHIFT IMAGING IN SELLAR AND PARASELLAR LESIONS
    KETONEN, L
    KIM, B
    SIMON, JH
    KIDO, DK
    SZUMOWSKI, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 905 - 906