Experimental study on a small flux, high pressure peristaltic micropump

被引:0
|
作者
Du, Min [1 ]
Lu, Zhengmao [1 ]
Ye, Xiongying [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instruments & Mechanol, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
来源
MICRO-NANO TECHNOLOGY XIII | 2012年 / 503卷
关键词
microfluidics; micropump; pulsatile flow; soft lithography; MICROFLUIDIC DEVICES;
D O I
10.4028/www.scientific.net/KEM.503.354
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, we improved the design of a membrane peristaltic micropump. The pump was driven by a rotating motor with magnetically attracted steel balls on top. The size of the micropump was significantly reduced to realize small flow rate and high pressure, to serve for precision delivering applications. Testing results showed that the pump can realize small flow rate from 0.93 to 12.73 mu L/min, with very high linearity. The back pressure could reach more than 83 kPa until the PDMS (polydimethylsiloxane) channel structure was destroyed under high pressure. The pulsation problem of the peristaltic pump was also mentioned, as well as the possible solution to deliver a certain amount of small sample volume.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 50 条
  • [1] High-Pressure Peristaltic Membrane Micropump With Temperature Control
    Svensson, Stefan
    Sharma, Gunjana
    Ogden, Sam
    Hjort, Klas
    Klintberg, Lena
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2010, 19 (06) : 1462 - 1469
  • [2] Development of a high performance peristaltic micropump
    Pham, My
    Goo, Nam Seo
    Lee, Man-Jong
    [J]. MULTI-FUNCTIONAL MATERIALS AND STRUCTURES, PTS 1 AND 2, 2008, 47-50 : 726 - 729
  • [3] Development of a high performance peristaltic micropump
    Pham, My
    Goo, Nam Seo
    [J]. NANOSENSORS AND MICROSENSORS FOR BIO-SYSTEMS 2008, 2008, 6931
  • [4] Analytical and experimental study of a valveless piezoelectric micropump with high flowrate and pressure load
    Jiafeng Ni
    Weipeng Xuan
    Yilin Li
    Jinkai Chen
    Wenjun Li
    Zhen Cao
    Shurong Dong
    Hao Jin
    Lingling Sun
    Jikui Luo
    [J]. Microsystems & Nanoengineering, 9
  • [5] Analytical and experimental study of a valveless piezoelectric micropump with high flowrate and pressure load
    Ni, Jiafeng
    Xuan, Weipeng
    Li, Yilin
    Chen, Jinkai
    Li, Wenjun
    Cao, Zhen
    Dong, Shurong
    Jin, Hao
    Sun, Lingling
    Luo, Jikui
    [J]. MICROSYSTEMS & NANOENGINEERING, 2023, 9 (01)
  • [6] Research on a Peristaltic Micropump with Normally Closed Valves Driven By Vacuum Pressure
    Cui, Jianguo
    Wang, Hong
    [J]. OPTICAL, ELECTRONIC MATERIALS AND APPLICATIONS II, 2012, 529 : 200 - 204
  • [7] A study on the development of a continuous peristaltic micropump using magnetic fluids
    Kim, EG
    Oh, J
    Choi, B
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2006, 128 (01) : 43 - 51
  • [8] A STUDY OF A HIGH-PRESSURE MICROPUMP FOR INTEGRATED CHEMICAL ANALYZING SYSTEMS
    SHOJI, S
    ESASHI, M
    VANDERSCHOOT, B
    DEROOIJ, N
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1992, 32 (1-3) : 335 - 339
  • [9] Induction electrohydrodynamics micropump for high heat flux cooling
    Singhal, Vishal
    Garimella, Suresh V.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2007, 134 (02) : 650 - 659
  • [10] EXPERIMENTAL STUDY OF PERISTALTIC PUMPING
    WEINBERG, SL
    ECKSTEIN, EC
    SHAPIRO, AH
    [J]. JOURNAL OF FLUID MECHANICS, 1971, 49 (OCT15) : 461 - +