Performance evaluation of cobas HBV real-time PCR assay on Roche cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test

被引:11
|
作者
Kim, Hanah [2 ]
Hur, Mina [1 ]
Bae, Eunsin [3 ]
Lee, Kyung-A [4 ]
Lee, Woo-In [5 ]
机构
[1] Konkuk Univ, Sch Med, Dept Lab Med, Med Ctr, 120-1 Neungdong Ro, Seoul 05030, South Korea
[2] Konkuk Univ, Sch Med, Dept Lab Med, Seoul, South Korea
[3] Vet Healthcare Syst Med Ctr, Dept Lab Med, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[5] Kyung Hee Univ, Sch Med, Dept Lab Med, Seoul, South Korea
关键词
cobas; 4800; COBAS CAP/CTM; cobas HBV; comparison; hepatitis B virus; performance; HEPATITIS-B-VIRUS; DNA; QUANTIFICATION; GENOTYPES;
D O I
10.1515/cclm-2017-1133
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Hepatitis B virus (HBV) nucleic acid amplification testing (NAAT) is important for the diagnosis and management of HBV infection. We evaluated the analytical performance of the cobas HBV NAAT (Roche Diagnostics GmbH, Mannheim, Germany) on the cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test (CAP/CTM HBV). Methods: Precision was evaluated using three levels of cobas HBV/HCV/HIV-1 Control Kit, and linearity was evaluated across the anticipated measuring range (10.0-1.0 x 10(9) IU/mL) at seven levels using clinical samples. Detection capability, including limit of blank (LOB), limit of detection (LOD) and limit of quantitation (LOQ), was verified using the 4th WHO International Standard for HBV DNA for NAT (NIBSC code: 10/266). Correlation between the two systems was compared using 205 clinical samples (102 sera and 103 EDTA plasma). Results: Repeatability and total imprecision (coefficient of variation) ranged from 0.5% to 3.8% and from 0.5% to 3.5%, respectively. Linearity (coefficient of determination, R-2) was 0.999. LOB, LOD and LOQ were all acceptable within the observed proportion rate (85%). Correlation was very high between the two systems in both serum and plasma samples (correlation coefficient [r] = 0.995). Conclusions: The new cobas HBV real-time PCR assay on the cobas 4800 System showed reliable analytical performances.
引用
收藏
页码:1133 / 1139
页数:7
相关论文
共 50 条
  • [1] Reproducibility of Roche cobas HIV-1, HBV and HCV real-time PCR assays on cobas 4800 in comparison with COBAS AmpliPrep/COBAS TaqMan assay equivalents
    Samat, M. N. Abdul
    Rashid, Z. Zainol
    Noordin, A.
    Ghulam, N. H.
    Ismail, N.
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 101 : 197 - 197
  • [2] Multicenter Evaluation of Cobas HCV Real-Time PCR Assay on the Roche Cobas 4800 System in Comparison with COBAS AmpliPrep/COBAS TaqMan HCV Test: Leading Circle for Cobas 4800 Virology (LCCV) Project
    Lee, W.
    Baek, J.
    Kim, H.
    Hur, M.
    Bae, E.
    Lee, K.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2017, 19 (06): : 983 - 983
  • [3] Performance of the cobas Hepatitis B virus (HBV) test using the cobas 4800 system and comparison of HBV DNA quantification ability between the COBAS AmpliPrep/COBAS TaqMan HBV test version 2.0 and cobas HBV test
    Shin, Kyung-Hwa
    Lee, Hyun-Ji
    Chang, Chulhun L.
    Kim, Hyung-Hoi
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2018, 101 : 47 - 51
  • [4] Comparison of the Abbott RealTime HBV assay with the Roche Cobas AmpliPrep/Cobas TaqMan HBV assay for HBV DNA detection and quantification
    Yeh, Ming-Lun
    Huang, Chung-Feng
    Hsieh, Ming-Yen
    Huang, Jee-Fu
    Dai, Chia-Yen
    Yu, Ming-Lung
    Chuang, Wan-Long
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2014, 60 (03) : 206 - 214
  • [5] Evaluation of the Roche COBAS AmpliPrep/COBAS TaqMan HCV Test
    Pyne, Michael T.
    Hillyard, David R.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2013, 77 (01) : 25 - 30
  • [6] Verification of the Roche COBAS HIV-1, HCV and HBV Tests on the COBAS 6800 System and Correlation to the COBAS Ampliprep/COBAS TaqMan System
    Sabato, M.
    Barto, L.
    Margaritini, C.
    Earles, S.
    Anaya-Bergman, C.
    Sene, M.
    Ferreira-Gonzalez, A.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2019, 21 (06): : 1164 - 1164
  • [7] Verification of the Roche Real-Time PCR COBAS AmpliPrep/COBAS TaqMan 48 HCV Test With the Roche COBAS AMPLICOR HCV Monitor, Version 2.0 Assay
    Varma, Tanya
    McRae, Kenneth L.
    Fogle, Edward
    Rinaudo, Stephanie
    Matthews-Greer, Janice
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 134 (04) : 689 - 689
  • [8] COBAS AmpliPrep-COBAS TaqMan hepatitis B virus (HBV) test: a novel automated real-time PCR assay for quantification of HBV DNA in plasma
    Allice, Tiziano
    Cerutti, Francesco
    Pittaluga, Fabrizia
    Varetto, Silvia
    Gabella, Silvia
    Marzano, Alfredo
    Franchello, Alessandro
    Colucci, Giuseppe
    Ghisetti, Valeria
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (03) : 828 - 834
  • [9] Verification of the COBAS AmpliPrep/COBAS TaqMan HBV Test ver. 2.0
    Lebel, K. A.
    Bissaillon, C. L.
    Steinmetz, H. B.
    Tsongalis, G. J.
    Moore, F.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (06): : 676 - 676
  • [10] Performance Evaluation of the COBAS® Ampliprep/COBAS® TaqMan® HCV Test
    Gunsolly, C. S.
    Bossler, A. D.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587