Assessment of cardiac parameters using gated myocardial perfusion and echocardiography in children

被引:4
|
作者
Kiratli, Pinar O. [1 ]
Bozkurt, Murat F. [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Nucl Med, TR-06100 Ankara, Turkey
关键词
Ejection fraction; end-diastolic volume; end-systolic volume; radionuclide imaging; M-mode echocardiography; LEFT-VENTRICULAR FUNCTION; EJECTION FRACTION; SPECT; QUANTIFICATION; VALIDATION; VOLUMES; IMAGES; MOTION;
D O I
10.1017/S1047951108003375
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Echocardiographic and radionuclide techniques are the most common techniques currently used to assess ventricular function. The aim of our study was to assess the performance of two well-known methods for analysis of gated myocardial perfusion with comparison to echocardiography in children. We analyzed the data from 64 children referred for myocardial perfusion scintigraphy. All underwent echocardiography and stress gated myocardial perfusion scintigraphy, except 5 who had only rest scintigraphy. We calculated the left ventricular volumes and ejection fractions. The parametric information from the echocardiographic reports was compared to the data obtained using gated myocardial perfusion. The reliability between the quantitative gated scintigraphy, the Emory cardiac toolbox, and echocardiography for end-diastolic and end-systolic volumes and ejection fractions in studies performed at rest were calculated at 0.85, 0.86 and 0.97, respectively using Cronbach's alpha coefficient. The values in stress studies were 0.83, 0.86 and 0.90, respectively. There was a high correlation, with r more than 0.88, between quantitative gated scintigraphy and the Emory cardiac toolbox for ejection fractions, and end-diastolic and end-systolic volumes, in studies performed both under stress and at rest. Weak correlation was observed between quantitative gated scintigraphy and the Emory cardiac toolbox compared to echocardiography, especially when considering ventricular volumes in stress studies. Although high correlation was observed between quantitative gated scintigraphy and the Emory cardiac toolbox, comparison with echocardiography showed poor agreement for both, meaning that scintigraphy is less suitable for assessing left ventricular volumes, and less reliable in assessment of ejection fractions. Echocardiography seems to remain the most widely used and reliable technique for this part of the diagnostic work up.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [1] Gated Myocardial Perfusion Scintigraphy in Children with Sickle Cell Anemia: Correlation with Echocardiography
    Hallioglu, O.
    Gunay, E. Ceylan
    Unal, S.
    Erdogan, A.
    Balci, S.
    Citirik, D.
    [J]. REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2011, 30 (06): : 354 - 359
  • [2] Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: Comparison with echocardiography
    Cwajg, E
    Cwajg, J
    He, ZX
    Hwang, WS
    Keng, F
    Nagueh, SF
    Verani, MS
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (11) : 1857 - 1865
  • [3] Assessment of myocardial perfusion by contrast echocardiography
    Thomas, HM
    [J]. CORONARY ARTERY DISEASE, 2000, 11 (03) : 201 - 202
  • [4] Myocardial perfusion assessment with contrast echocardiography
    Desco, M
    Ledesma-Carbayo, MJ
    Santos, A
    García-Fernandez, M
    Marcos-Alberca, P
    Malpica, N
    Antoranz, JC
    Garcia-Barreno, P
    [J]. MEDICAL IMAGING 2001: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2001, 4325 : 514 - 522
  • [5] Contrast echocardiography for assessment of myocardial perfusion
    Leischik, R
    Rose, J
    Caspari, G
    Skyschally, A
    Heusch, G
    Erbel, R
    [J]. HERZ, 1997, 22 (01) : 40 - 50
  • [6] GATED CARDIAC POOL AND MYOCARDIAL PERFUSION STUDIES
    IIO, M
    TOYAMA, H
    MURATA, H
    CHIBA, K
    KAWAGUCHI, S
    YAMADA, H
    MATSUI, K
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1977, 18 (06) : 601 - 601
  • [7] Clinical impact of arrhythmias on gated SPECT cardiac myocardial perfusion and function assessment
    Kenneth Nichols
    Siu-Sun Yao
    Mohammad Kamran
    Tracy L. Faber
    C. David Cooke
    E. Gordon DePuey
    [J]. Journal of Nuclear Cardiology, 2001, 8 : 19 - 30
  • [8] Clinical impact of arrhythmias on gated SPECT cardiac myocardial perfusion and function assessment
    Nichols, K
    Yao, SS
    Kamran, M
    Faber, TL
    Cooke, CD
    DePuey, EG
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (01) : 19 - 30
  • [9] Value of gated SPECT myocardial perfusion imaging for individual cardiac risk assessment
    Nowak, B
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 2005, 94 : 81 - 84
  • [10] Can left ventricular parameters examined by gated myocardial perfusion scintigraphy and strain echocardiography be prognostic factors for major adverse cardiac events?
    Karacavus, Seyhan
    Celik, Ahmet
    Tutus, Ahmet
    Kula, Mustafa
    Oguzhan, Abdurrahman
    Kalay, Nihat
    [J]. HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2014, 17 (01): : 10 - 11