The migration of Proteus mirabilis and other urinary tract pathogens over Foley catheters

被引:45
|
作者
Sabbuba, N [1 ]
Hughes, G [1 ]
Stickler, DJ [1 ]
机构
[1] Cardiff Univ, Cardiff Sch Biosci, Cardiff CF1 3TL, S Glam, Wales
关键词
catheter-associated infection; urinary tract pathogens; bacterial migration; catheter colonization;
D O I
10.1046/j.1464-4096.2001.01721.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective To examine the ability of organisms that infect the catheterized urinary tract to migrate over the surfaces of Foley catheters. Materials and methods In a simple laboratory model, organisms were challenged to migrate across sections of hydrogel-coated latex, hydrogel/silver-coated latex, silicone-coated latex and all-silicone catheters. The sections (1 cm long) were placed as bridges in channels between blocks of agar and the test organisms inoculated onto the agar adjacent to one side of each bridge. The plates were incubated at 37degreesC for 24 h and examined for growth of the test organisms on the agar on the other side of the bridges. A collection of swarming, swimming and nonmotile species were tested in the model. The relative mobilities of the test organisms were expressed as migration indices, calculated as the percentage of tests in which bacterial migration was observed over each type of catheter bridge. Results The swarmer cells of Proteus mirabilis and P. vulgaris migrated successfully (migration indices of 73-100) over all four types of catheter. The migration index of Serratia marcescens swarmers was reduced to 33 over the silver-coated catheters, but these cells crossed over the other catheter surfaces with ease (indices of 100). Pseudomonas aeruginosa was the most mobile of the swimming, non-swarming organisms with indices of 70-22. but this group was less capable of migration than the swarmers. Indices were 0-33 for nonmotile organisms. The mean migration indices for the nine species for each type of catheter were 5 7 (hydrogel-coated latex), 49 (silver/hydrogel-coated latex), 41 (silicone-coated latex) and 35 (all-silicone). The swarmer cells of P. mirabilis moved through populations of Escherichia coli, Klebsiella pneumoniae, Staphylococcus aureus and Enterococcus faecalis, and then migrated over sections of hydrogel-coated latex catheters with little or no reduction in migration index. They were also capable of transporting the nonmotile cells of K. pneumoniae and S. aureus over the catheters. The migration index of P. mirabilis swarmers was substantially reduced in the presence of Ps, aeruginosa and S. marcescens. Conclusions Hydrogel coatings facilitate the migration of urinary tract pathogens over catheter surfaces. With the exception of S. marcescens, the incorporation of silver into the hydrogel did not inhibit migration. Swarmer cells were particularly effective at moving over catheters and P. mirabilis swarmers were also capable of transporting other species. This suggests that inhibitors of swarming could be useful in controlling catheter-associated infection and the complications resulting from the spread of bacterial biofilm over catheters.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [1] Some observations on the migration of Proteus mirabilis and other urinary tract pathogens over Foley catheters
    Williams, Gareth J.
    Stickler, David J.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (05): : 443 - 445
  • [2] Proteus mirabilis and Urinary Tract Infections
    Schaffer, Jessica N.
    Pearson, Melanie M.
    MICROBIOLOGY SPECTRUM, 2015, 3 (05):
  • [3] Pathogenesis of Proteus mirabilis urinary tract infection
    Coker, C
    Poore, CA
    Li, X
    Mobley, HLT
    MICROBES AND INFECTION, 2000, 2 (12) : 1497 - 1505
  • [4] Ability of Proteus mirabilis to Swarm over Urethral Catheters
    D. Stickler
    G. Hughes
    European Journal of Clinical Microbiology and Infectious Diseases, 1999, 18 : 206 - 208
  • [5] Ability of Proteus mirabilis to swarm over urethral catheters
    Stickler, D
    Hughes, G
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1999, 18 (03) : 206 - 208
  • [6] Modulation of crystalline Proteus mirabilis biofilm development on urinary catheters
    Stickler, DJ
    Morgan, SD
    JOURNAL OF MEDICAL MICROBIOLOGY, 2006, 55 (05) : 489 - 494
  • [7] Inhibition of urease activity in the urinary tract pathogens Staphylococcus saprophyticus and Proteus mirabilis by dimethylsulfoxide (DMSO)
    Deutch, Charles E.
    JOURNAL OF APPLIED MICROBIOLOGY, 2020, 128 (05) : 1514 - 1523
  • [8] Proteus mirabilis spondylodiscitis complicating a urinary tract infection
    Smits, Jeroen P. P.
    Peltenburg, Henny G.
    Mooi-Kokenberg, Esther A. N. M.
    Koster, Ted
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2006, 38 (6-7) : 575 - 576
  • [9] Role of swarming in the formation of crystalline Proteus mirabilis biofilms on urinary catheters
    Jones, BV
    Mahenthiralingam, E
    Sabbuba, NA
    Stickler, DJ
    JOURNAL OF MEDICAL MICROBIOLOGY, 2005, 54 (09) : 807 - 813
  • [10] Bacteriophage Can Prevent Encrustation and Blockage of Urinary Catheters by Proteus mirabilis
    Nzakizwanayo, Jonathan
    Hanin, Aurelie
    Alves, Diana R.
    McCutcheon, Benjamin
    Dedi, Cinzia
    Salvage, Jonathan
    Knox, Karen
    Stewart, Bruce
    Metcalfe, Anthony
    Clark, Jason
    Gilmore, Brendan F.
    Gahan, Cormac G. M.
    Jenkins, A. Toby A.
    Jones, Brian V.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2016, 60 (03) : 1530 - 1536