The quality of megavoltage photon beams measured by the ratio of photoactivation and neutron capture yields

被引:3
|
作者
Krmar, M. [1 ]
Teterev, Y. [2 ]
Belov, A. G. [2 ]
Mitrofanov, S. [2 ]
机构
[1] Univ Novi Sad, Phys Dept, Fac Sci, Novi Sad, Serbia
[2] Joint Inst Nucl Res, Flerov Lab Nucl React, Dubna, Russia
关键词
Bremsstrahlung; Endpoint energy; Photoneutrons; Photoactivation; Gamma spectroscopy; END-POINT ENERGY; BREMSSTRAHLUNG;
D O I
10.1016/j.nima.2018.06.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The activities of products of two photonuclear reactions (In-113(gamma,gamma')(11)(3m) In and(115)In(gamma,gamma')(115) In-m) and neutron capture (In-115(n, gamma)In-116(m) ) were measured. The measurements were made to verify that obtained activities (as well as some of their ratios) change sufficiently with the change of the energy, so that the activation of the indium could be recommended as a sensitive test for the control of the endpoint energy (and beam quality) of bremsstrahlung beams in an energy region usually used in radiation therapy. Mikrotron photon beam was used for photoactivation, and the source of neutrons was the mikrotron tungsten target itself, at energies higher than threshold for (gamma, n) reaction. At lower energies, neutrons were produced in Be target inserted in photon beam. It was obtained that sensitive index of endpoint energy variation can be obtained in a broad energy region from 5 MeV to 23 MeV by different combinations of saturation activities of three reaction products. The described measurements can be used to develop a very sensitive and simple method in a routine quality control of photon beams of megavoltage devices used in radiotherapy.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 20 条
  • [1] Quality assurance of measured depth dose for megavoltage photon beams
    Thompson, AV
    Zhu, TC
    Bjärngard, BE
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3108 - 3111
  • [2] Modeling the output ratio in air for megavoltage photon beams
    Zhu, TC
    Bjärngard, BE
    Xiao, Y
    Yang, CJ
    MEDICAL PHYSICS, 2001, 28 (06) : 925 - 937
  • [3] On beam quality and flatness of radiotherapy megavoltage photon beams
    Hossain, Murshed
    Rhoades, Jeffrey
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) : 135 - 145
  • [4] On beam quality and flatness of radiotherapy megavoltage photon beams
    Murshed Hossain
    Jeffrey Rhoades
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 135 - 145
  • [5] Modeling scatter-to-primary dose ratio for megavoltage photon beams
    Wang, Ken Kang-Hsin
    Zhu, Timothy C.
    MEDICAL PHYSICS, 2010, 37 (10) : 5270 - 5278
  • [6] The Beam Quality Dependence of a Radiophotoluminescent Glass Dosimeter in Megavoltage Photon and Electron Beams
    Araki, F.
    Ohno, T.
    Yoshiyama, F.
    Kohno, T.
    Wulff, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments
    Mobit, PN
    Mayles, P
    Nahum, AE
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03): : 387 - 398
  • [8] Single-use MOSFET radiation dosimeters for the quality assurance of megavoltage photon beams
    Briere, TM
    Lii, J
    Prado, K
    Gillin, MT
    Beddar, AS
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05): : 1139 - 1144
  • [9] Photon strength functions, level densities, and isomeric ratio in 168Er from the radiative neutron capture measured at the DANCE facility
    Knapova, I.
    Couture, A.
    Fry, C.
    Kvasil, J.
    Krticka, M.
    Nesterenko, V. O.
    O'Donnell, J. M.
    Prokop, C. J.
    Rusev, G.
    Ullmann, J. L.
    Valenta, S.
    PHYSICAL REVIEW C, 2023, 107 (04)
  • [10] A new analytical model for the response curve in megavoltage photon beams of the radiochromic EBT3 films measured with flatbed scanners
    Rodriguez, Cesar
    Garcia-Pinto, Diego
    Carlos Martinez, Luis
    Lopez-Fernandez, Alfonso
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (08):