Acoustic Chemometric At-Line Characterization for Monitoring Particle Size Fractions in Pneumatically Conveyed Biomass

被引:0
|
作者
Ihunegbo, Felicia Nkem [1 ]
Wagner, Claas [2 ]
Esbensen, Kim H. [1 ,2 ,3 ]
Halstensen, Maths [1 ]
机构
[1] Telemark Univ Coll, ACRG, N-3901 Porsgrunn, Norway
[2] Aalborg Univ, ACABS Res Grp, Aalborg, Denmark
[3] Geol Survey Denmark & Greenland, Copenhagen, Denmark
关键词
Acoustic chemometrics; biomass; fine-fraction estimation; partial least squares regression (PLS-R); process analytical technology (PAT); theory of sampling (TOS); FLOW REGIME DETERMINATION; RELIABLE DATA-ANALYSIS; PROBES; FEASIBILITY; PREDICTION; BIOSLURRY; TRANSPORT; TUTORIAL; PAT;
D O I
10.1080/02726351.2013.809394
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Reliable on-line/at-line prediction of particle size fractions of biomass material is a process monitoring concern owing to inherent variation in particle size and difficulty in sampling of pneumatically ducted biomass material. A feasibility study on application of acoustic chemometrics for at-line prediction of size fractions of biomass material has been performed, with all models subjected to independent test set validation. This study serves as a platform for at-line characterization of biomass samples from a sampling device extracting biomass samples from pneumatic conveying systems (based on theory of sampling). A prestudy using complex biomass/plastic pellets mixtures was used to test reliability and robustness of the experimental setup. Promising prediction results were achieved (slope, relative root mean square error of prediction (RMSEPrel), and correlation coefficient (r(2)) were 1.08, 24.94%, and 0.90, respectively). The same experimental setup was adapted for quantitative prediction of coarse versus fine biomass mixtures (the main objective) with satisfactory results; slope=0.96, r(2)=0.97, RMSEP(rel)=11%. A case study was also performed showing the adverse effect of using nonrepresentative coarse versus fine biomass samples for calibration. It is concluded that acoustic chemometrics is a viable technique for at-line prediction of size fractions of representative biomass materials.
引用
收藏
页码:70 / 79
页数:10
相关论文
共 50 条
  • [1] On-line particle sizing of pneumatically conveyed biomass particles using piezoelectric sensors
    Gao, Lingjun
    Yan, Yong
    Carter, Robert M.
    Sun, Duo
    Lee, Peter
    Xu, Chuanlong
    FUEL, 2013, 113 : 810 - 816
  • [2] On-line size measurement of pneumatically conveyed particles through acoustic emission sensing
    Zhang, Guoqiang
    Yan, Yong
    Hu, Yonghui
    Zheng, Ge
    POWDER TECHNOLOGY, 2019, 353 : 195 - 201
  • [3] A modal analysis technique for the on-line particle size measurement of pneumatically conveyed pulverised coal
    Hancke, GP
    Malan, R
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 848 - 852
  • [4] Particle size determination by impact measurement in pneumatically conveyed solids
    Coghill, PJ
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2001, 18 (03) : 114 - 119
  • [5] A modal analysis technique for the on-line particle size measurement of pneumatically conveyed pulverized coal
    Hancke, GP
    Malan, R
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (01) : 114 - 122
  • [6] Particle size of pneumatically conveyed powders measured using impact duration
    Coghill, Peter J.
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2007, 24 (06) : 464 - 469
  • [7] Concurrent Measurement of the Size Distribution and Velocity of Pneumatically Conveyed Biomass Solids Using Acoustic Emission and Electrostatic Sensors
    Zheng, Ge
    Yan, Yong
    Wang, Lijuan
    Hu, Yonghui
    Zeng, Xingxing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [8] At-line DLS for real-time monitoring of particle size in a nanoemulsion process
    Mahoney, Max
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [9] Online continuous measurement of the size distribution of pneumatically conveyed particles by acoustic emission methods
    Hu, Yonghui
    Qian, Xiangchen
    Huang, Xiaobin
    Gao, Lingjun
    Yan, Yong
    FLOW MEASUREMENT AND INSTRUMENTATION, 2014, 40 : 163 - 168
  • [10] In-line Particle Sizing of Pneumatically Conveyed Particles Using a Piezo Film Sensor
    Gao, Lingjun
    Yan, Yong
    Carter, Robert M.
    Sun, Duo
    Xu, Chuanlong
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 625 - 628