Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), Flame Atomic Absorption Spectrometry (FAAS) and Visible Spectrometry (VS) was applied for determination of Ag and Li in lithium-aluminium alloy standard sample and test sample, their respective advantages and disadvantages were compared, the excellent selectivity of ICP-OES was confirmed by analyses of certified standard sample. Three different sample digestion methods were compared and discussed in this study. It was found that the better accuracy would be obtained by digesting sample with chloroazotic acid while the content of Li was measured by FAAS, and it was better to digest sample with hydrochloric acid and hydrogen peroxide while determining Ag and Li by ICP-OES simultaneously and determining Ag by FAAS and VS. The interference of co-existing elements and elimination methods was detailedly discussed. Ammonium hydroxide was added to adjust the sample solution into alkalescent and Al, Ti, Zr was precipitated by forming hydroxide precipitation, Mg and Cu was formed complex precipitation with 8-hydroxyquinoline in this condition, then the interference from matrix element to determinate Ag by FAAS was eliminated. In addition, phosphate was used to precipitate Ti to eliminate its interference for determination of Li by FAAS. The same treatment of determination for Ag by FAAS was used to eliminate the interference of matrix element for determination of Ag by VS, the excess of nitrate was added into sample and heated to release Ag+ from silver chloride complex, and the color of 8-hydroxyquinoline was eliminated because of decomposed by heating. The accuracy of analysis result for standard sample was conspicuously improved which confirms the efficient of the method to eliminate interference in this study. The optimal digestion method and eliminate interference method was applied to lithium-aluminium alloy samples. The recovery of samples was from 100.39% to 103.01% by ICP-OES determination for Ag, and from 100.42% to 103.01% by ICP-OES determination for Li. The recovery ranged from 95.91% to 99.98% by FAAS determination for Ag, and ranged from 98.04% to 99.98% for FAAS determination of Li. The recovery was from 98.00% to 101.00 by VS determination for Ag, the analysis results all meet the analysis requirement.
引用
收藏
页码:2886 / 2890
页数:5
相关论文
共 7 条
  • [1] [陈雪 CHEN Xue], 2009, [光谱实验室, Chinese Journal of Spectroscopy laboratory], V26, P1685
  • [2] [陈雪 CHEN Xue], 2009, [光谱实验室, Chinese Journal of Spectroscopy laboratory], V26, P1682
  • [3] 李建舫, 2008, [理化检验. B, 化学分册, Physical Testing and Chemical Analysis], V44, P794
  • [4] LIU Jian-guo, 1997, CHINESE J SPECTROSCO, V14, P52
  • [5] TAO Ting-xian, 1996, J ANHUI I MECH ELECT, V11, P62
  • [6] ICP-AES Determination of 15 Kind of impurity elements in the Vanadium-aluminum alloy
    Yonga, Cheng
    [J]. INTERNATIONAL CONFERENCE ON ADVANCES IN ENGINEERING 2011, 2011, 24 : 447 - 453
  • [7] [周西林 Zhou Xilin], 2013, [冶金分析, Metallurgical Analysis], V33, P64