5-year Clinical Outcomes of Biodegradable Polymer Biolimus-eluting Stents versus Durable Polymer Sirolimus-eluting Stents in Patients with and without Diabetes Mellitus: a LEADERS Sub-study

被引:0
|
作者
Linke, Axel [1 ]
Buszman, Pawel [2 ]
Serruys, Patrick [3 ]
Ischinger, Thomas [4 ]
Antoni, Diethmar [5 ]
Klauss, Volker [6 ]
Sohn, Hae-Young [7 ]
Eberli, Franz [8 ]
Corti, Roberto [9 ]
Wijns, William [10 ]
Morice, Marie-Claude [11 ]
Di Mario, Carlo [12 ]
Juni, Peter [13 ]
Windecker, Stephan [14 ]
机构
[1] Univ Leipzig, Leipzig, Germany
[2] Amer Heart Poland, Ustron, Poland
[3] Erasmus Univ, Thoraxctr, NL-3000 DR Rotterdam, Netherlands
[4] Kardiol Zentrum, Munich, Germany
[5] Heart Ctr Munich Bogenhausen, Munich, Germany
[6] Kardiol Innenstadt, Munich, Germany
[7] Univ Munich, Med Klin, Munich, Germany
[8] Stadtspital Triemli, Zurich, Switzerland
[9] Univ Spital Zurich, Zurich, Switzerland
[10] Cardiovasc Ctr Aalst, Aalst, Belgium
[11] Inst Cardiovasc Paris Sud, Massy, France
[12] Royal Brompton Hosp, London SW3 6LY, England
[13] CTU Bern, Bern, Switzerland
[14] Univ Hosp Bern, CH-3010 Bern, Switzerland
关键词
D O I
10.1016/j.jacc.2012.08.604
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:B165 / B166
页数:2
相关论文
共 50 条
  • [1] Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents
    Lee, Da Hyon
    Park, Taek Kyu
    Bin Song, Young
    Chun, Woo Jung
    Choi, Rak Kyeong
    Jeong, Jin-Ok
    Im, Eul Soon
    Kim, Sang Wook
    Lee, Joo Myung
    Yang, Jeong Hoon
    Hahn, Joo-Yong
    Choi, Seung-Hyuk
    Choi, Jin-Ho
    Lee, Sang Hoon
    Gwon, Hyeon-Cheol
    PLOS ONE, 2017, 12 (08):
  • [2] Five-year outcomes in patients with diabetes mellitus treated with biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents
    Iglesias, J. F.
    Heg, D.
    Roffi, M.
    Tueller, D.
    Lanz, J.
    Rigamonti, F.
    Muller, O.
    Moarof, I.
    Cook, S.
    Weilenmann, D.
    Kaiser, C.
    Valgimigli, M.
    Jueni, P.
    Windecker, S.
    Pilgrim, T.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1257 - 1257
  • [3] Five-Year Outcomes in Patients With Diabetes Mellitus Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents
    Iglesias, Juan F.
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Lanz, Jonas
    Rigamonti, Fabio
    Mueller, Olivier
    Moarof, Igal
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Cuculi, Florim
    Valgimigli, Marco
    Juni, Peter
    Windecker, Stephan
    Pilgrim, Thomas
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [4] Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents
    Jakobsen, Lars
    Christiansen, Evald H.
    Maeng, Michael
    Hansen, Knud N.
    Kristensen, Steen D.
    Botker, Hans E.
    Terkelsen, Christian J.
    Jensen, Svend E.
    Raungaard, Bent
    Madsen, Morten
    Lassen, Jens F.
    Jensen, Lisette O.
    EUROINTERVENTION, 2017, 13 (11) : 1337 - 1345
  • [5] 5-year outcomes in patients with acute coronary syndrome treated with biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents
    Iglesias, J. F.
    Heg, D.
    Roffi, M.
    Tueller, D.
    Muller, O.
    Moarof, I
    Cook, S.
    Weilenmann, D.
    Kaiser, C.
    Valgimigli, M.
    Juni, P.
    Windecker, S.
    Pilgrim, T.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2533 - 2533
  • [6] Randomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents: Nine months angiographic and 5-year clinical outcomes
    Zhang, Haijun
    Wang, Xiangfei
    Deng, Wei
    Wang, Shenguo
    Ge, Junbo
    Toft, Egon
    MEDICINE, 2016, 95 (38)
  • [7] Long-term vascular response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents
    Kuramitsu, S.
    Sonoda, S.
    Yokoi, H.
    Iwabuchi, M.
    Domei, T.
    Shirai, S.
    Ando, K.
    Nobuyoshi, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1142 - 1142
  • [8] Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent)
    Vlachojannis, Georgios J.
    Smits, Pieter C.
    Hofma, Sjoerd H.
    Togni, Mario
    Vazquez, Nicolas
    Valdes, Mariano
    Voudris, Vassilis
    Slagboom, Ton
    Goy, Jean-Jaques
    den Heijer, Peter
    van der Ent, Martin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12) : 1215 - 1221
  • [9] 2-Year Clinical Follow-Up From the Randomized Comparison of Biolimus-Eluting Stents With Biodegradable Polymer and Sirolimus-Eluting Stents With Durable Polymer in Routine Clinical Practice
    Klauss, Volker
    Serruys, Patrick W.
    Pilgrim, Thomas
    Buszman, Pawel
    Linke, Axel
    Ischinger, Thomas
    Eberli, Franz
    Corti, Roberto
    Wijns, William
    Morice, Marie-Claude
    di Mario, Carlo
    van Geuns, Robert Jan
    van Es, Gerrit-Anne
    Kalesan, Bindu
    Wenaweser, Peter
    Jueni, Peter
    Windecker, Stephan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (08) : 887 - 895