New method for mercury determination in microwave digested soil samples based on cold vapor capacitively coupled plasma microtorch optical emission spectrometry: Comparison with atomic fluorescence spectrometry

被引:35
|
作者
Frentiu, Tiberiu [1 ]
Mihaltan, Alin Ironim [2 ]
Senila, Marin [2 ]
Darvasi, Eugen [1 ]
Ponta, Michaela [1 ]
Frentiu, Maria [2 ]
Pintican, Bogdan Petru [1 ]
机构
[1] Univ Babes Bolyai, Fac Chem & Chem Engn, Cluj Napoca 400028, Romania
[2] Natl Inst Res & Dev Optoelect Bucharest, Res Inst Analyt Instrumentat, Cluj Napoca 400293, Romania
关键词
Mercury determination; Cold vapor; Soil; Capacitively coupled plasma; Optical emission spectrometry; Atomic fluorescence spectrometry; Bland-Altman test; GENERATION; SPECIATION; SEDIMENTS; PLANT; HG;
D O I
10.1016/j.microc.2013.06.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensitive method for total mercury determination in digested soils using a miniaturized analytical system based on cold vapor capacitively coupled plasma microtorch optical emission spectrometry was developed and compared with cold vapor atomic fluorescence spectrometry as the standardized method. The soil samples were subjected to microwave digestion in aqua regia, than Hg cold vapor were chemically generated with SnCl2 and introduced via a 150 ml min(-1) Ar flow rate in the plasma microtorch operated at 10 W power level. The optical emission signal at 253.652 nm was measured with a commercially available microspectrometer. The method detection limit was 4.8 mu g kg(-1) Hg, similar to that obtained in the standardized reference method. The precision of Hg determination over the concentration range of 0.27-55 mg kg(-1) was 0.8-7.7%. Analysis of six CRMs revealed a recovery of 97 +/- 7% similar to 97 +/- 9% found in the method based on cold vapor atomic fluorescence spectrometry. The Bland and Altman test carried out on 31 test soil samples showed no significant statistical difference between the results obtained by the proposed method and that taken as reference. The investigated analytical system can be prototyped as an alternative for the commercially existing atomic fluorescence spectrometry instrumentation. The benefits of the system are related to small size instrumentation and low analysis cost due to the low power and low Ar consumption for plasma generation. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:545 / 552
页数:8
相关论文
共 50 条
  • [1] Mercury determination in non- and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry
    Frentiu, Tiberiu
    Mihaltan, Alin I.
    Ponta, Michaela
    Darvasi, Eugen
    Frentiu, Maria
    Cordos, Emil
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 193 : 65 - 69
  • [2] A microanalytical method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for multielemental determination: comparison with inductively coupled plasma optical emission spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Darvasi, Eugen
    Ponta, Michaela
    Frentiu, Maria
    Petreus, Dorin
    CHEMICAL PAPERS, 2017, 71 (01) : 91 - 102
  • [3] A microanalytical method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for multielemental determination: comparison with inductively coupled plasma optical emission spectrometry
    Tiberiu Frentiu
    Sinziana Butaciu
    Eugen Darvasi
    Michaela Ponta
    Maria Frentiu
    Dorin Petreus
    Chemical Papers, 2017, 71 : 91 - 102
  • [4] Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry - comparison with inductively coupled plasma optical emission spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Ponta, Michaela
    Darvasi, Eugen
    Senila, Marin
    Petreus, Dorin
    Frentiu, Maria
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (10) : 1880 - 1888
  • [5] Sono-induced cold vapour generation interfaced with capacitively coupled plasma microtorch optical emission spectrometry: analytical characterization and comparison with atomic fluorescence spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Darvasi, Eugen
    Ponta, Michaela
    Senila, Marin
    Levei, Erika Andrea
    Frentiu, Maria
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (05) : 1161 - 1168
  • [6] Methylmercury determination in seafood by photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry
    Covaci, Eniko
    Senila, Marin
    Ponta, Michaela
    Darvasi, Eugen
    Petreus, Dorin
    Frentiu, Maria
    Frentiu, Tiberiu
    TALANTA, 2017, 170 : 464 - 472
  • [7] Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry-comparison with inductively coupled plasma optical emission spectrometry
    20143900072302
    Frentiu, Tiberiu, 1880, Royal Society of Chemistry (29):
  • [8] Determination of Total Mercury in Fish Tissue Using a Low-Cost Cold Vapor Capacitively Coupled Plasma Microtorch Optical Emission Microspectrometer: Comparison with Direct Mercury Determination by Thermal Decomposition Atomic Absorption Spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Ponta, Michaela
    Senila, Marin
    Darvasi, Eugen
    Frentiu, Maria
    Petreus, Dorin
    FOOD ANALYTICAL METHODS, 2015, 8 (03) : 643 - 648
  • [9] Determination of Total Mercury in Fish Tissue Using a Low-Cost Cold Vapor Capacitively Coupled Plasma Microtorch Optical Emission Microspectrometer: Comparison with Direct Mercury Determination by Thermal Decomposition Atomic Absorption Spectrometry
    Tiberiu Frentiu
    Sinziana Butaciu
    Michaela Ponta
    Marin Senila
    Eugen Darvasi
    Maria Frentiu
    Dorin Petreus
    Food Analytical Methods, 2015, 8 : 643 - 648
  • [10] Determination of mercury in radioactive samples by cold vapor atomic fluorescence spectrometry
    Jasperson, MN
    Drake, LR
    PLUTONIUM FUTURES-THE SCIENCE, 2000, 532 : 350 - 351