3D Blood Vessel Mapping of Adult Zebrafish using High Frequency Ultrasound Ultrafast Doppler Imaging

被引:0
|
作者
Chang, Chao-Chuan [1 ]
Chen, Pei-Yu [1 ]
Huang, Chih-Chung [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
关键词
adult zebrafish; ultrafast ultrasound; power Doppler imaging; band-pass spatiotemporal filtering; 3D blood mapping;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The zebrafish is an ideal vertebrate for studying developmental biology and genetics due to its external development and optical transparency in embryonic stages. Recently, with the rapid generation rate and genetic accessibility, adult zebrafish have been used to model tumorigenesis, angiogenesis, and regeneration in vivo. However, once the zebrafish has fully matured, especially wild-type lines, it develops stripes that run along the body and thus lose transparency. Owing to that, conventional optical imaging techniques will have difficulty for imaging the internal anatomy and vasculature. High frequency ultrasound imaging is one useful modality for overcoming this opacity problem. However, using conventional ultrasound Doppler imaging to depict the vascular imaging is limited by diffraction and frame-rates. Hence, the purpose of this study is to utilize ultrafast ultrasound with high frequency transducer to reconstruct the 3D blood mapping of adult zebrafish. A high-frequency transducer (operational frequency = 31.25 MHz, 256 elements) connected to a programmable ultrafast ultrasound system with a custom-built adapter was used in this study as an imaging platform. Experiments were carried out by 6-8 months old wild-type (AB line) adult zebrafish. The ultrafast imaging was performed from a five angles plane wave (from -3 degrees to 3 degrees with 1.5 degrees incremental steps) at a total frame rate of 1000 fps. The linear array transducer was fixed on a 3-axis stepper motor stage and the transducer was placed at the left-right coordinates of the center of the fish, to obtain the ultrafast imaging across the dorsal side of zebrafish. Then, the acquisition data was compounded to improve signal-to-noise-ratio (SNR) and was processed with a band-pass spatiotemporal filter to extract the blood flow information for Doppler imaging. Following reconstruction, segmented images were skeletonized to produce the 3D blood map of dorsal side on zebrafish with high voxel resolution (19.68 mu m x 24.64 mu m x 50 mu m). The result shows a strong potential for depicting the blood mapping of the adult zebrafish using ultrafast Doppler imaging, which would help for modeling adult zebrafish on tumorigenesis and tissue regeneration via ultrasound images in vivo.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] In Vivo Visualization of Vasculature in Adult Zebrafish by Using High-Frequency Ultrafast Ultrasound Imaging
    Chang, Chao-Chuan
    Chen, Pei-Yu
    Huang, Hsin
    Huang, Chih-Chung
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (06) : 1742 - 1751
  • [2] In Vivo 3D Power Doppler Imaging Using Continuous Translation and Ultrafast Ultrasound
    Chen, Chuan
    Hendriks, Gijs A. G. M.
    Fekkes, Stein
    Mann, Ritse M.
    Menssen, Jan
    Siebers, Carmen C. N.
    de Korte, Chris L.
    Hansen, Hendrik H. G.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (03) : 1042 - 1051
  • [3] 3D imaging of teeth using high frequency ultrasound
    Hughes, David A.
    Button, Tim W.
    Cochran, Sandy
    Elgoyhen, Jocelyn
    Girkin, John M.
    Hughes, Hana
    Longbottom, Christopher
    Meggs, Carl
    Poland, Simon
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 327 - +
  • [4] High-Resolution Tissue Doppler and Strain Imaging for Adult Zebrafish Myocardial Tissue Through Ultrafast High-Frequency Ultrasound Vector Doppler Estimation
    Huang, Hsin
    Machikhin, Alexander
    Chen, De-Quan
    Huang, Chih-Chung
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (08) : 1006 - 1018
  • [5] Monitoring of Adult Zebrafish Heart Regeneration Using High-Frequency Ultrasound Spectral Doppler and Nakagami Imaging
    Yeo, Sunmi
    Yoon, Changhan
    Lien, Ching-Ling
    Song, Tai-Kyong
    Shung, K. Kirk
    [J]. SENSORS, 2019, 19 (19)
  • [6] 2 In vivo cardiac imaging of adult zebrafish using high frequency ultrasound
    Sun, Lei
    Lien, Ching-Ling
    Shung, K. Kirk
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1500 - +
  • [7] 3D ultrafast ultrasound imaging in vivo
    Provost, Jean
    Papadacci, Clement
    Arango, Juan Esteban
    Imbault, Marion
    Fink, Mathias
    Gennisson, Jean-Luc
    Tanter, Mickael
    Pernot, Mathieu
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : L1 - L13
  • [8] 3-D Ultrafast Doppler Imaging Applied to the Noninvasive Mapping of Blood Vessels In Vivo
    Provost, Jean
    Papadacci, Clement
    Demene, Charlie
    Gennisson, Jean-Luc
    Tanter, Mickael
    Pernot, Mathieu
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (08) : 1467 - 1472
  • [9] 3D printed phantom for high frequency ultrasound imaging
    Jacquet, Jean-Rene
    Levassort, Franck
    Ossant, Frederic
    Gregoire, Jean-Marc
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [10] Quantitative imaging of coronary flows using 3D ultrafast Doppler coronary angiography
    Correia, M.
    Maresca, D.
    Goudot, G.
    Villemain, O.
    Bize, A.
    Sambin, L.
    Tanter, M.
    Ghaleh, B.
    Pernot, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (10):