Quantitative sudomotor axon reflex test (QSART):: A new approach for testing distal sites

被引:0
|
作者
Riedel, A
Braune, S
Kerum, G
Schulte-Mönting, J
Lücking, CH
机构
[1] Univ Freiburg, Neurol Klin, D-79106 Freiburg, Germany
[2] Univ Freiburg, Dept Diabetol, Freiburg, Germany
[3] Univ Freiburg, Dept Med Biometry & Stat, Freiburg, Germany
关键词
C fiber; diabetic neuropathy; distal site; quantitative sudomotor axon reflex test;
D O I
10.1002/(SICI)1097-4598(199909)22:9<1257::AID-MUS14>3.0.CO;2-J
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The quantitative sudomotor axon reflex test (QSART) is a useful tool in the evaluation of C-fiber function. Because many neuropathies show a length-dependent loss of nerve function, a new capsule was designed for distal performance of the QSART, allowing measurements on fingers and toes. We investigated 20 healthy volunteers and 15 patients with insulin-dependent diabetes mellitus and normal sensory nerve conduction studies. A QSART was performed on the forearm and on the thumb. The groups showed no differences in the QSARTs on the forearm, but the sweat volume on the thumb was significantly lower in patients. Calculation of the forearm/finger ratio reduced the interindividual variation and showed the highest sensitivity for detecting C-fiber dysfunction in the patient group. We conclude that the distal measuring device and the forearm/finger ratio are more sensitive tools for the early detection of distal-onset neuropathies than are the commonly used proximal testing sites. (C) 1999 John Wiley & Sons, Inc.
引用
收藏
页码:1257 / 1264
页数:8
相关论文
共 50 条
  • [1] The quantitative sudomotor axon reflex testing (QSART)
    Bickel, A
    Hilz, MJ
    [J]. NERVENHEILKUNDE, 2000, 19 (05) : 259 - 263
  • [2] Reliability of the Quantitative Sudomotor Axon Reflex Test (QSART) Using QSWEAT
    Abou-Zeid, Elias
    Artibee, Kay
    Shi, Yaping
    Wang, Lily
    Peltier, Amanda
    [J]. NEUROLOGY, 2011, 76 (09) : A575 - A575
  • [3] RELATIONSHIP OF Q-SWEAT TO QUANTITATIVE SUDOMOTOR AXON REFLEX TEST (QSART) VOLUMES
    Sletten, David M.
    Weigand, Stephen D.
    Low, Phillip A.
    [J]. MUSCLE & NERVE, 2010, 41 (02) : 240 - 246
  • [4] QUANTITATIVE SUDOMOTOR AXON REFLEX TEST (QSART) STUDY IN POSTURAL ORTHOSTATIC TACHYCARDIA SYNDROME (POTS)
    Ashangari, C.
    Suleman, A.
    [J]. CARDIOLOGY, 2015, 131 : 300 - 300
  • [5] AGAROSE BASED ACETYLCHOLINE REDUCES QUANTITATIVE SUDOMOTOR AXON REFLEX TEST'S (QSART) FALSE POSITIVES
    Arvantaj, Ali
    Spencer, Karen
    Tsirambidis, Sally
    Mantz, Kimberly
    Robinson, Jenice
    Katirji, Bashar
    [J]. MUSCLE & NERVE, 2018, 58 : S8 - S8
  • [6] Test-Retest Reliability of Quantitative Sudomotor Axon Reflex Testing
    Berger, Michael J.
    Kimpinski, Kurt
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2013, 30 (03) : 308 - 312
  • [7] Age- and sex-related differences in sudomotor function evaluated by the quantitative sudomotor axon reflex test (QSART) in healthy humans
    Lee, Jeong Beom
    Lee, In Ho
    Shin, Young Oh
    Min, Young Ki
    Yang, Hun Mo
    [J]. CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2014, 41 (06): : 392 - 399
  • [8] Incidence of quantitative sudomotor axon reflex test (QSART) abnormalities in patients diagnosed with idiopathic Parkinson's disease
    Cristini, J.
    Hanna, P. A.
    Rosenberg, M.
    [J]. MOVEMENT DISORDERS, 2009, 24 : S319 - S319
  • [9] Early detection of orthostatic hypotension by quantitative sudomotor axon reflex test (QSART) in type 2 diabetic patients
    Itoh, H
    Uebori, S
    Asai, M
    Kashiwaya, T
    Atoh, K
    Makino, I
    [J]. INTERNAL MEDICINE, 2003, 42 (07) : 560 - 564
  • [10] QUANTITATIVE SUDOMOTOR AXON REFLEX TEST IN NORMAL AND NEUROPATHIC SUBJECTS
    LOW, PA
    CASKEY, PE
    TUCK, RR
    FEALEY, RD
    DYCK, PJ