The Experimental Use of N-Butyl Cyanoacrylate Tissue Adhesive in Pulmonary Wedge Resections

被引:4
|
作者
Kosar, Altug [1 ]
Kapicibasi, H. Oguz [2 ]
Alpay, A. Levent [2 ]
Misirlioglu, Aysun K. [2 ]
Sonmez, Hakan [2 ]
Iskender, Ilker [2 ]
Demirhan, Recep
机构
[1] Dr Lutfi Kirdar Kartal Training & Res Hosp, Dept Thorac Surg, TR-34734 Istanbul, Turkey
[2] Sureyyapasa Chest Dis & Chest Surg Training & Res, Istanbul, Turkey
来源
HEART LUNG AND CIRCULATION | 2012年 / 21卷 / 11期
关键词
N-Butyl cyanoacrylate; Pulmonary wedge resections; Surgery; Tissue adhesives; PROLONGED AIR LEAK; SURGICAL APPLICATIONS; LUNG RESECTION; SEALANT; PREVENTION; PARENCHYMA; MODEL; GLUE;
D O I
10.1016/j.hlc.2012.06.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In this experimental study, the effectiveness of N-butyl cyanoacrylate tissue adhesive on preventing air leakage after pulmonary wedge resection was observed. Methods: Twenty pairs of sheep lungs were used. Before initiating the study, the sheep lungs were ventilated to identify any air leakage from the parenchyma. On positive results, those sheep lungs were then excluded from the study. Wedge resection was performed on the right and left lower lobes of sheep lungs by clamping the edges forming a triangle of 5 cm x 5 cm x 5 cm. One side of parenchyma was sutured by 3/0 vicryl (Group A) while the other side of parenchyma was sealed by N-butyl cyanoacrylate (Group B). After waiting for 5 min for N-butyl cyanoacrylate to dry, the sheep lungs were intubated by 6 F endotracheal tubes. The lungs were soaked in a bath tub filled with 10 cm deep water and inflated by 40 mmHg pressure to record any air leakage from the parenchyma partially sutured by vicryl and sealed by N-butyl cyanoacrylate. Results: Air leakages were observed on the parenchyma surfaces of group of lungs (100%) sutured by vicryl (minimal 30%, mild 50% or massive 20% levels), while only on four of (20%) the other group of lungs sealed by N-butyl cyanoacrylate, minimal air leakage was observed on the parenchymal surface. There was an extremely significant difference between Group A and Group B in terms of the development of air leakage (p = 000). Conclusion: We consider that, N-butyl cyanoacrylate could be used effectively and safely to prevent air leakage from the pulmonary wedge resection surface. (Heart, Lung and Circulation 2012;21:711-714) (C) 2012 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:711 / 714
页数:4
相关论文
共 50 条
  • [1] Experimental use of N-butyl cyanoacrylate tissue adhesive on lung parenchyma after pulmonary resection
    Cagirici, U.
    Cetin, Y.
    Cakan, A.
    Samancilar, O.
    Veral, A.
    Askar, F. Z.
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 2007, 55 (03): : 180 - 181
  • [2] INTESTINAL ANASTOMOSIS WITH N-BUTYL CYANOACRYLATE TISSUE ADHESIVE
    MATSUMOTO, T
    HARDAWAY, RM
    PANI, KC
    LEONARD, F
    HEISTERKAMP, CA
    MARGETIS, PM
    [J]. SURGERY, 1967, 61 (04) : 567 - +
  • [3] Evaluation of n-Butyl Cyanoacrylate Adhesive in Rat Subcutaneous Tissue
    Mestieri, Leticia Boldrin
    Saska, Sybele
    Carrodeguas, Raul Garcia
    Minarelli Gaspar, Ana Maria
    [J]. DERMATOLOGIC SURGERY, 2012, 38 (05) : 767 - 771
  • [4] Clinical experience with N-butyl cyanoacrylate tissue adhesive in fungal keratitis
    Garg, P
    Gopinathan, U
    Nutheti, R
    Rao, GN
    [J]. CORNEA, 2003, 22 (05) : 405 - 408
  • [5] CLINICAL-EXPERIENCE WITH N-BUTYL CYANOACRYLATE (NEXACRYL) TISSUE ADHESIVE
    LEAHEY, AB
    GOTTSCH, JD
    STARK, WJ
    [J]. OPHTHALMOLOGY, 1993, 100 (02) : 173 - 180
  • [6] DEGRADATION OF N-BUTYL ALPHA CYANOACRYLATE TISSUE ADHESIVE .2.
    PANI, KC
    GLADIEUX, G
    BRANDES, G
    KULKARNI, RK
    LEONARD, F
    [J]. SURGERY, 1968, 63 (03) : 481 - &
  • [7] A traumatic ossicular disruption successfully repaired with n-butyl cyanoacrylate tissue adhesive
    Adamson, RM
    Jeannon, JP
    Stafford, F
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2000, 114 (02): : 130 - 131
  • [8] Use of n-butyl 2-cyanoacrylate tissue adhesive to splint traumatised teeth in the emergency department
    Cobb, Alistair R. M.
    Ahmad, Seif
    Kumar, Mahesh
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2011, 49 (06): : 483 - 485
  • [9] Enteroplication in cats, using suture of N-butyl cyanoacrylate adhesive
    Nash, JM
    Bellenger, CR
    [J]. RESEARCH IN VETERINARY SCIENCE, 1998, 65 (03) : 253 - 258
  • [10] Clinical Experience With N-Butyl Cyanoacrylate Tissue Adhesive in Corneal Perforations Secondary to Herpetic Keratitis
    Moorthy, Sonia
    Jhanji, Vishal
    Constantinou, Marios
    Beltz, Jacqueline
    Graue-Hernandez, Enrique O.
    Vajpayee, Rasik B.
    [J]. CORNEA, 2010, 29 (09) : 971 - 975