Transvenous cardioverter-defibrillator implantation in a patient with tricuspid mechanical prosthesis

被引:7
|
作者
Biffi, Mauro [1 ]
Bertini, Matteo [1 ]
Ziacchi, Matteo [1 ]
Boriani, Giuseppe [1 ]
机构
[1] Univ Bologna, Inst Cardiol, I-40138 Bologna, Italy
关键词
cardioverter-defibrillator; prosthetic mechanical valve; ventricular tachycardia;
D O I
10.1111/j.1540-8167.2006.00686.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. A 64-year-old woman was referred to our center because of poorly tolerated ventricular tachycardia (VT) at 210 bpm due to an old myocardial infarction. The patient had been operated on at age of 20 for mitral valve commissurolysis, at age of 49 for ductal carcinoma, at age of 56 for mitral valve replacement, and at age of 61 for tricuspid valve replacement. Left ventricular EF was 31%. The patient was in permanent atrial fibrillation (AF) since the age of 53. She had undergone three cardiac surgery procedures, ending with two prosthetic mechanical valves. The cardiac surgery team advised against an epicardial ICD implantation. Results. We achieved a fully transvenous implant, with a screw-in defibrillation coil in the low right atrium and a bipolar pacing/sensing lead in a posterolateral branch of the coronary sinus. Pacing/sensing parameters were reliable, and effective defibrillation occurred at 20 J by a stepdown protocol. During 16-month follow-up, three VT episodes at 210 bpm were terminated by antitachycardia pacing (ATP) therapy. Left ventricular pacing/sensing was stable at long term. Conclusion. Thanks to technologic improvements, transvenous ICD implantation is feasible and safe in patients with a tricuspid mechanical prosthesis.
引用
收藏
页码:329 / 331
页数:3
相关论文
共 50 条
  • [1] Successful extravascular implantable cardioverter-defibrillator implantation in a patient with recurrent transvenous implantable cardioverter-defibrillator erosion
    Robinson, Andrea
    Billakanty, Sreedhar
    Fu, Eugene
    Amin, Anish
    [J]. HEART RHYTHM O2, 2024, 5 (04): : 243 - 245
  • [2] Transvenous-subcutaneous implantation of a cardioverter-defibrillator after bioprosthetic replacement of a tricuspid valve
    Doll, N
    Dähnert, I
    Dorszewski, A
    Bernau, H
    Wetzel, U
    Schneider, P
    Gummert, JF
    Mohr, FW
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 2003, 92 (06): : 490 - 493
  • [3] Transvenous cardioverter-defibrillator lead implantation in a patient with three mechanical prosthetic valves: All in one solution
    Cay, Serkan
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 165 (02) : E33 - E34
  • [4] Tricuspid Regurgitation Following Implantation of a Pacemaker/Cardioverter-Defibrillator
    Al-Mohaissen, Maha A.
    Chan, Kwan Leung
    [J]. CURRENT CARDIOLOGY REPORTS, 2013, 15 (05)
  • [5] Tricuspid Regurgitation Following Implantation of a Pacemaker/Cardioverter-Defibrillator
    Maha A. Al-Mohaissen
    Kwan Leung Chan
    [J]. Current Cardiology Reports, 2013, 15
  • [6] Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation
    Chang, James D.
    Manning, Warren J.
    Ebrille, Elisa
    Zimetbaum, Peter J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (18) : 2331 - 2341
  • [7] Implantation of a cardioverter-defibrillator in a patient with cardiac amyloidosis
    Wright, BLC
    Grace, AA
    Goodman, HJB
    [J]. NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2006, 3 (02): : 110 - 114
  • [8] Implantation of a cardioverter-defibrillator in a patient with cardiac amyloidosis
    Ben LC Wright
    Andrew A Grace
    Hugh JB Goodman
    [J]. Nature Clinical Practice Cardiovascular Medicine, 2006, 3 : 110 - 114
  • [9] ARRHYTHMIAS AFTER CARDIOVERTER-DEFIBRILLATOR IMPLANTATION - COMPARISON OF EPICARDIAL AND TRANSVENOUS SYSTEMS
    ONG, JJC
    HSU, PC
    LIN, L
    YU, A
    KASS, RM
    PETER, T
    SWERDLOW, CD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (02): : 137 - 140
  • [10] TOTAL PECTORAL IMPLANTATION - A NEW TECHNIQUE FOR IMPLANTATION OF TRANSVENOUS DEFIBRILLATOR LEAD SYSTEMS AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    CAMUNAS, J
    MEHTA, D
    IP, J
    PE, E
    GOMES, JA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (07): : 1380 - 1385