Operational TanDEM-X DEM calibration and first validation results

被引:105
|
作者
Gruber, Astrid [1 ]
Wessel, Birgit [1 ]
Huber, Martin [1 ]
Roth, Achim [1 ]
机构
[1] German Aerosp Ctr DLR, German Remote Sensing Data Ctr DFD, D-82234 Oberpfaffenhofen, Wessling, Germany
关键词
Block adjustment; DEM; Calibration; InSAR; TanDEM-X;
D O I
10.1016/j.isprsjprs.2012.06.002
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
In June 2010, the German TanDEM-X satellite was launched. Together with its twin satellite TerraSAR-X it flies in a close formation enabling single-pass SAR interferometry. The primary goal of the TanDEM-X mission is the derivation of a global digital elevation model (DEM) with unprecedented global accuracies of 10 m in absolute and 2 m in relative height. A significant calibration effort is required to achieve this high quality world-wide. In spite of an intensive instrument calibration and a highly accurate orbit and baseline determination, some systematic height errors like offsets and tilts in the order of some meters remain in the interferometric DEMs and have to be determined and removed during the TanDEM-X DEM calibration. The objective of this article is the presentation of an approach for the estimation of correction parameters for remaining systematic height errors applicable to interferometric height models. The approach is based on a least-squares block adjustment using the elevation of ICESat GLA 14 data as ground control points and connecting points of adjacent, overlapping DEMs as tie-points. In the first part its implementation in DLR's ground segment is outlined. In the second part the approach is applied and validated for two of the first TanDEM-X DEM test sites. Therefore, independent reference data, in particular high resolution reference DEMs and GPS tracks, are used. The results show that the absolute height errors of the TanDEM-X DEM are small in these cases, mostly in the order of 1-2 m. An additional benefit of the proposed block adjustment method is that it improves the relative accuracy of adjacent DEMs. (C) 2012 International Society for Photogrammetry and Remote Sensing, Inc. (ISPRS) Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 49
页数:11
相关论文
共 50 条
  • [1] THE GLOBAL TANDEM-X DEM: PRODUCTION STATUS AND FIRST VALIDATION RESULTS
    Huber, M.
    Gruber, A.
    Wendleder, A.
    Wessel, B.
    Roth, A.
    Schmitt, A.
    [J]. XXII ISPRS CONGRESS, TECHNICAL COMMISSION VII, 2012, 39 (B7): : 45 - 50
  • [2] Status of TanDEM-X DEM Calibration and Mosaicking towards the TanDEM-X DEM
    Wessel, Birgit
    Gruber, Astrid
    Huber, Martin
    Breunig, Markus
    Wagenbrenner, Susanne
    Roth, Achim
    [J]. 10TH EUROPEAN CONFERENCE ON SYNTHETIC APERTURE RADAR (EUSAR 2014), 2014,
  • [3] DEM calibration concept for TanDEM-X
    Gonzalez, J. Hueso
    Bachmann, M.
    Fiedler, H.
    Huber, S.
    Krieger, G.
    Zink, M.
    [J]. IGARSS: 2007 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-12: SENSING AND UNDERSTANDING OUR PLANET, 2007, : 4487 - 4490
  • [4] Development of TanDEM-X DEM calibration concept
    Gonzalez, J. Hueso
    Bachmann, M.
    Fiedler, H.
    Huber, S.
    Krieger, G.
    Wessel, B.
    Zink, M.
    [J]. 2007 EUROPEAN MICROWAVE CONFERENCE, VOLS 1-4, 2007, : 1743 - +
  • [5] TESTS OF THE TANDEM-X DEM CALIBRATION PERFORMANCE
    Gonzalez, Jaime Hueso
    Antony, John Walter
    Bachmann, Markus
    Krieger, Gerhard
    Schwerdt, Marco
    Zink, Manfred
    [J]. 2012 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2012, : 303 - 306
  • [6] Development of TanDEM-X DEM calibration concept
    Gonzalez, J. Hueso
    Bachmann, M.
    Fiedler, H.
    Huber, S.
    Krieger, G.
    Wesse, B.
    Zink, M.
    [J]. 2007 EUROPEAN RADAR CONFERENCE, 2007, : 463 - +
  • [7] CALIBRATION OF THE TANDEM-X CRAW DEMS FOR THE TANDEM-X DEM CHANGE MAPS GENERATION
    Schweisshelm, Barbara
    Lachaise, Marie
    [J]. 2022 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2022), 2022, : 291 - 294
  • [8] Status of TanDEM-X DEM Acquisition, Calibration and Performance
    Schulze, Daniel
    Bachmann, Markus
    Braeutigam, Benjamin
    Borla-Tridon, Daniela
    Rizzoli, Paola
    Martone, Michele
    Zink, Manfred
    Krieger, Gerhard
    [J]. 10TH EUROPEAN CONFERENCE ON SYNTHETIC APERTURE RADAR (EUSAR 2014), 2014,
  • [9] Results of the TanDEM-X Baseline Calibration
    Antony, John Walter
    Gonzalez, Jaime Hueso
    Schwerdt, Marco
    Bachmann, Markus
    Krieger, Gerhard
    Zink, Manfred
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2013, 6 (03) : 1495 - 1501
  • [10] The TanDEM-X Change DEM: the new temporal DEM of the TanDEM-X Mission
    Lachaise, Marie
    Bachmann, Markus
    Fritz, Thomas
    Huber, Martin
    Schweisshelm, Barbara
    Wessel, Birgit
    [J]. 13TH EUROPEAN CONFERENCE ON SYNTHETIC APERTURE RADAR, EUSAR 2021, 2021, : 550 - 555