Indoor air quality analyses of commercial reference buildings

被引:36
|
作者
Ng, Lisa C. [1 ]
Musser, Amy [2 ]
Persily, Andrew K. [1 ]
Emmerich, Steven J. [1 ]
机构
[1] NIST, IAQ & Ventilat Grp, Gaithersburg, MD 20899 USA
[2] Vandemusser Design PLLC, Asheville, NC 28804 USA
关键词
Indoor air quality; CONTAM; Reference buildings; Simulation; PENETRATION; PARTICLES; SYMPTOMS; OZONE; MODEL;
D O I
10.1016/j.buildenv.2012.07.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sixteen commercial reference buildings were created in the multizone airflow and contaminant transport program CONTAM in order to support airflow and indoor air quality (IAQ) analyses, which are not possible using the existing EnergyPlus input files for these buildings. Annual airflow and contaminant simulations were performed in CONTAM for six of the buildings. Contaminant analyses were performed for occupant-generated carbon dioxide (CO2), volatile organic compounds (VOC) from indoor sources, outdoor particulate matter, and outdoor ozone. In all of the selected buildings and zones, the simulated indoor ozone and PM 2.5 concentrations did not exceed indoor limits set by the World Health Organization. For CO2 and VOC, for which no similarly relevant indoor concentration standards or limits exist, the simulated concentrations were within expected ranges based on published field measurements in commercial buildings. The results of this study provide a baseline for subsequent use of these models to investigate approaches to building ventilation and other technologies that are intended to simultaneously reduce building energy consumption while maintaining or improving indoor air quality. Published by Elsevier Ltd.
引用
收藏
页码:179 / 187
页数:9
相关论文
共 50 条
  • [1] Ventilation and Indoor Air Quality in 40 Small and Medium Sized Commercial Buildings in California: Indoor Air Quality Methods and Findings
    Bennett, Deborah
    Apte, Michael
    Trout, Amber
    Powers, Michael
    Maddalena, Randy
    Russell, Marion
    [J]. EPIDEMIOLOGY, 2011, 22 (01) : S44 - S44
  • [2] Improving Indoor Air Quality Through The Use of Ultraviolet Technology In Commercial Buildings
    de Robles, Daniel
    Kramer, Scott W.
    [J]. CREATIVE CONSTRUCTION CONFERENCE 2017, CCC 2017, 2017, 196 : 888 - 894
  • [3] Indoor air quality - buildings design
    Senitkova, Ingrid Juhasova
    [J]. 8TH INTERNATIONAL SCIENTIFIC CONFERENCE BUILDING DEFECTS (BUILDING DEFECTS 2016), 2016, 93
  • [4] INDOOR AIR QUALITY OF THE OFFICE BUILDINGS
    Senitkova, Ingrid
    Tomcik, Tomas
    [J]. CESB 10: CENTRAL EUROPE TOWARDS SUSTAINABLE BUILDING - FROM THEORY TO PRACTICE, 2010, : 517 - 520
  • [5] Indoor air quality for residential buildings
    Sherman, M
    [J]. ASHRAE JOURNAL, 1999, 41 (05) : 26 - 30
  • [6] Energy Optimization of HVAC Systems in Commercial Buildings Considering Indoor Air Quality Management
    Yu, Liang
    Xie, Di
    Huang, Chongxin
    Jiang, Tao
    Zou, Yulong
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (05) : 5103 - 5113
  • [7] Characterization of indoor and ambient air quality in modern commercial and recreational complex buildings in Hanoi
    Duong, Van Minh
    Hoang, Anh Le
    [J]. ATMOSPHERIC ENVIRONMENT, 2022, 291
  • [8] Indoor Air Quality in Buildings: A Comprehensive Review on the Factors Influencing Air Pollution in Residential and Commercial Structure
    Mannan, Mehzabeen
    Al-Ghamdi, Sami G.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (06) : 1 - 24
  • [9] Air quality control in commercial buildings
    Liddament, MW
    [J]. RENEWABLE ENERGY, 1996, 8 (1-4) : 231 - 235
  • [10] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229