Optimum design of micro-concave structure of needle valve body based on ANSYS simulation analysis

被引:0
|
作者
Zhao, Qiang [1 ]
Ma, Dan [2 ]
Cao, Yuxuan [2 ]
Zhu, Xueliang [3 ]
Zhao, Huiying [1 ]
机构
[1] Xi An Jiao Tong Univ, 28 West Xianning Rd, Xian 710049, Shaanxi, Peoples R China
[2] Shanxi Diesel Engine Ind Grp Co Ltd, 97 Daqing West Rd, Datong 037036, Peoples R China
[3] Xian Technol Univ, 2 Xuefu Middle Rd, Xian 710021, Shaanxi, Peoples R China
关键词
Needle valve coupler; needle valve body; micro concave structure; simulation analysis; optimized design;
D O I
10.1117/12.2521928
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For a certain type of needle valve coupler under the working condition, the high pressure oil is easy to leak from the contact end face of the needle valve body and the needle spring seat, so the Solidworks software was used to establish the overall 3D model of the needle valve coupler and design different micro concave structures. Then use Ansys simulation analysis software to simulate the working conditions to statically simulate the micro-concave structure on the needle body. According to the simulation analysis results, the micro-concave structure on the needle valve body was optimized, so that the high-pressure oil leakage problem was improved.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Design and analysis of plunger valve based on ansys
    Wang, Gang
    Zhang, Rong
    Wang, Jing
    Wang, Wei
    Xie, Maoyi
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON INNOVATIVE MATERIAL SCIENCE AND TECHNOLOGY (IMST 2016), 2016, 139 : 491 - 498
  • [2] Fabricating of double layered flexible pressure sensor with a high-sensitivity based on inkjet printed micro-concave structure
    Ma, Mengdi
    Sun, Rui
    Li, Sen
    Kang, Haiting
    Wang, Shuo
    Chu, Fuqiang
    Sun, Jiazhen
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 351
  • [3] Design and Simulation of Micro-pump, Micro-valve and Micro-needle for Biomedical Applications
    Podder, Pranay Kanti
    Mallick, Dhiman
    Samajdar, Dip Prakash
    Bhattacharyya, Anirban
    2012 5TH INTERNATIONAL CONFERENCE ON COMPUTERS AND DEVICES FOR COMMUNICATION (CODEC), 2012,
  • [4] Design and analysis of MEMS based piezoelectric micro pump integrated with micro needle
    Rao, K. Srinivasa
    Sateesh, J.
    Guha, Koushik
    Baishnab, K. L.
    Ashok, P.
    Sravani, K. Girija
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2020, 26 (10): : 3153 - 3159
  • [5] Design and analysis of MEMS based piezoelectric micro pump integrated with micro needle
    K. Srinivasa Rao
    J. Sateesh
    Koushik Guha
    K. L. Baishnab
    P. Ashok
    K. Girija Sravani
    Microsystem Technologies, 2020, 26 : 3153 - 3159
  • [6] Design and Model Analysis of City Bus Body Frame Based on ANSYS
    Ren, Xiaozhong
    Du, Shaojie
    Pei, Xuesheng
    ADVANCED RESEARCH ON INFORMATION SCIENCE, AUTOMATION AND MATERIAL SYSTEM, PTS 1-6, 2011, 219-220 : 1389 - +
  • [7] The Design and Simulation Analysis of A Rotary Valve Based on FLUENT
    Du, Zhiwei
    Chen, Wei
    Li, Hao
    Yang, Xiuping
    Guo, Jinjin
    Su, Weihua
    Zhang, Xizheng
    2016 IEEE/CSAA INTERNATIONAL CONFERENCE ON AIRCRAFT UTILITY SYSTEMS (AUS), 2016, : 646 - 650
  • [8] Structure Design and Simulation Analysis of Multiple Micro Piezoelectric Cantilevers
    Jiang, Anran
    Geo, Shiqiao
    Yao, Fenglin
    He, Yunli
    MICRO-NANO TECHNOLOGY XIV, PTS 1-4, 2013, 562-565 : 1208 - 1213
  • [9] Design, simulation and experimental study of a micromixer based on Tesla valve structure
    Weng X.
    Yan S.
    Zhang Y.
    Liu J.
    Shen J.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (08): : 4173 - 4178
  • [10] GRATING LIGHT VALVE BASED ON HIGH REFLECTANCE MICRO-BEAMS: DESIGN BY SIMULATION
    Florin, Comanescu Constantin
    Tibeica, Catalin
    Purica, Munizer
    Schiopu, Paul
    2010 INTERNATIONAL SEMICONDUCTOR CONFERENCE (CAS), VOLS 1 AND 2, 2010, : 117 - 120