Routine serum protein analysis by capillary zone electrophoresis: Clinical evaluation

被引:6
|
作者
Lehmann, R [1 ]
Koch, M [1 ]
Voelter, W [1 ]
Haring, HU [1 ]
Liebich, HM [1 ]
机构
[1] UNIV TUBINGEN,PHYS BIOCHEM ABT,INST PHYS CHEM,D-72076 TUBINGEN,GERMANY
关键词
capillary electrophoresis; clinical evaluation; serum protein; cellulose acetate; LINEAR-REGRESSION PROCEDURES; SEPARATION; CHEMISTRY;
D O I
10.1007/BF02505590
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To measure the five classical protein fractions in human serum several electrophoretic techniques are available. Besides separation on cellulose acetate membrane or agarose gel, capillary zone electrophoresis (CZE) may be a useful analytical alternative in clinical routine. We have compared the Dionex CES I capillary electrophoresis system with that of the Olympus Fractoscan using specimens submitted for routine analysis. For clinical evaluation 102 samples from patients with various diseases have been analysed. Serum protein fractions were judged on separation performance, precision and the regression method of Bablok-Passing. Regression analysis revealed variable agreement between both methods with a slope +/- intercept of 2.10-0.52 (alpha(1)-fraction) and 1.0-0.20 (alpha(2)-fraction) as worse and best, resectively; and the coefficient of variation of migration time: 5.9 %-6.8 % (between-run imprecision). Differences in the comparison of fractions are mainly caused by the improved resolution of CZE, e.g. one beta-globulin peak on cellulose acetate is separated into two distinct protein fractions in CZE, including more detailed diagnostic information - as is also the case with gamma-fraction. In some cases monoclonal gammopathy with low concentrations of immunglobulin clone can only be detected in CZE, whereas the cellulose acetate membrane (CAME) electropherogram is inconspicuous. The within-run precision (N = 18) gave coefficients of variation of peak areas 1.3-5.9 % (CZE) and 1.0-3.8 % (cellulose acetate membrane), This is the first time that a complete clinical evaluation of CZE serum protein fraction analysis has been performed, CZE with its higher resolution and hence more detailed diagnostic information in some cases, showed good separation patterns, precision and correlation. Interchangeability of results showed that this CZE method is well suited for analysis of serum protein fractions in clinical routine.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [1] Routine serum protein analysis by capillary zone electrophoresis: Clinical evaluation
    R. Lehmann
    M. Koch
    W. Voelter
    H. U. Häring
    H. M. Liebich
    Chromatographia, 1997, 45 : 390 - 395
  • [2] Evaluation of the paragon CZE™ 2000 capillary zone electrophoresis system for serum protein electrophoresis in routine clinical laboratory.
    Hermsen, D
    Niederau, CM
    Reinauer, H
    CLINICAL CHEMISTRY, 1999, 45 (06) : A50 - A50
  • [3] Capillary zone electrophoresis in the evaluation of serum protein abnormalities
    Keren, DF
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (02) : 248 - 252
  • [4] Routine serum protein analysis using capillary electrophoresis
    Doelman, CJA
    Siebelder, CWM
    Penders, TJ
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1997, 35 (05): : 393 - 394
  • [5] Paragon CZE 2000 capillary zone electrophoresis system for routine serum protein analysis.
    Wahl, HG
    Faix, S
    Peterfi, C
    Häring, HU
    Liebich, HM
    CLINICAL CHEMISTRY, 1998, 44 : A20 - A20
  • [6] Comparison of serum protein electrophoresis by agarose gel and capillary zone electrophoresis in a clinical setting
    Jolliff, CR
    Blessum, CR
    ELECTROPHORESIS, 1997, 18 (10) : 1781 - 1784
  • [7] Analysis of micafungin in serum by capillary zone electrophoresis
    Kitahashi, Toshihiro
    Furuta, Itaru
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2007, 45 (01) : 28 - 32
  • [8] The advantages of serum protein separation by capillary zone electrophoresis
    Obradovic, I
    Dajak, M
    Novakovic, N
    Becarevic, M
    Majkic-Singh, N
    CLINICA CHIMICA ACTA, 2005, 355 : S234 - S234
  • [9] Interferences in clinical capillary zone electrophoresis of serum proteins
    Bossuyt, X
    ELECTROPHORESIS, 2004, 25 (10-11) : 1485 - 1487
  • [10] Comparison of a clinical capillary electrophoresis system with agarose gel electrophoresis for evaluation of serum protein abnormalities
    Kip, N. Sertac
    Lamb, Colleen
    Killeen, Anthony A.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (03) : 488 - 488