3D cell-based biosensor for cell viability and drug assessment by 3D electric cell/matrigel-substrate impedance sensing

被引:84
|
作者
Pan, Yuxiang [1 ,2 ]
Hu, Ning [1 ]
Wei, Xinwei [1 ]
Gong, Lin [3 ]
Zhang, Bin [1 ]
Wan, Hao [1 ]
Wang, Ping [1 ,2 ]
机构
[1] Zhejiang Univ, Biosensor Natl Special Lab, Key Lab Biomed Engn, Educ Minist,Dept Biomed Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] Chinese Acad Sci, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Zhejiang Univ, Sch Med, Hangzhou 310058, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
3D cell-based biosensors; 3D electric cell/matrigel-substrate impedance sensing; 3D cell viability; Anti-cancer drug screening in vitro; 3-DIMENSIONAL CULTURE; SYSTEMS; GAP;
D O I
10.1016/j.bios.2018.09.046
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Preclinical efficacy and toxicity assessment of drug candidates plays a significant role in drug discovery and development. Traditional planar cell culture is a common way to perform the preclinical drug test, but it is difficult to correctly predict the drug efficacy and toxicity due to the simple two-dimensional (2D) extracellular microenvironment. Compared to the planar cell culture, three-dimensional (3D) cell culture system can better mimic the complex extracellular microenvironment where cells reside in the 3D tissues/organs in vivo. However, the conventional imaging techniques are difficult to achieve the dynamic and label-free monitoring of cellular behavior in thick sample by 3D cell culture. Here, 3D electric cell/matrigel-substrate impedance sensing (3D-ECMIS) is developed for real-time and non-invasive monitoring of 3D cell viability and drug susceptibility. In this study, human hepatoma cells (HepG2) are encapsulated in the matrigel scaffold and cultured in a 3D ECMIS chip which involves a pair of vertical golden electrodes on the opposite sidewalls of the culture chamber for the in-situ impedance measurement. Moreover, a portable multichannel system is developed to monitor the 3D cell/matrigel construct. The number of 3D-cultured cells was inversely proportional to the impedance magnitude of the entire cell/matrigel construct. Furthermore, anti-cancer drug screening will be conducted on the 3D-cultured cells when the cell proliferation reaches to a plateau phase. To validate the performance of 3D-ECMIS for the cell viability and drug susceptibility, the cell live/dead staining are utilized to confirm the results of drug susceptibility by this 3D-cell-based biosensor system. It is demonstrated that the 3D cell-based biosensor and 3D-ECMIS system will be a promising platform to improve the accuracy of cell-based anti-cancer drug screening in vitro.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 50 条
  • [1] 3D microgroove electrical impedance sensing to examine 3D cell cultures for antineoplastic drug assessment
    Yuxiang Pan
    Deming Jiang
    Chenlei Gu
    Yong Qiu
    Hao Wan
    Ping Wang
    Microsystems & Nanoengineering, 6
  • [2] 3D microgroove electrical impedance sensing to examine 3D cell cultures for antineoplastic drug assessment
    Pan, Yuxiang
    Jiang, Deming
    Gu, Chenlei
    Qiu, Yong
    Wan, Hao
    Wang, Ping
    MICROSYSTEMS & NANOENGINEERING, 2020, 6 (01)
  • [3] 3D or not 3D: a guide to assess cell viability in 3D cell systems
    Bikmulina, Polina
    Kosheleva, Nastasia
    Efremov, Yuri
    Antoshin, Artem
    Heydari, Zahra
    Kapustina, Valentina
    Royuk, Valery
    Mikhaylov, Vasily
    Fomin, Victor
    Vosough, Massoud
    Timashev, Peter
    Rochev, Yury
    Shpichka, Anastasia
    SOFT MATTER, 2022, 18 (11) : 2222 - 2233
  • [4] Cell-based Sensing: From 2D to 3D Cell Culture
    Yang, L.
    Trivedi, G.
    Adcock, A. F.
    Tyson, W.
    CHEMICAL AND BIOLOGICAL SENSORS 11 -AND- MEMS-NEMS 11, 2014, 64 (01): : 125 - 132
  • [5] An integrated 3D cell-based electrochemical biosensor for neurotoxicity assessment of organophosphorus pesticides
    Wei, Xiaoou
    Liu, Chao
    Zhang, Xinai
    Li, Zhihua
    Wang, Xinyu
    Xu, Yiwei
    Shi, Jiyong
    Sun, Quancai
    Routledge, Michael N.
    Zhang, Di
    Zou, Xiaobo
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 376
  • [6] Challenges in 3D culturing of neutrophils: Assessment of cell viability
    Gonzalez, Miriam Gonzalez
    Cichon, Iwona
    Scislowska-Czarnecka, Anna
    Kolaczkowska, Elzbieta
    JOURNAL OF IMMUNOLOGICAL METHODS, 2018, 457 : 73 - 77
  • [7] Overview of 3D Cell Culture Model Systems & Validating Cell-based Assays for Use with 3D Cultures
    Riss, Terry
    IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY-ANIMAL, 2014, 50 : S7 - S8
  • [8] Biosensor Based on Electrical Impedance Tomography for 3D Cancer Cell Culture Imaging
    Claudel, Julien
    Mazerbourg, Sabine
    Lacroix, Victorine
    Bettenfeld, Remi
    Schlauder, Cyril
    Kourtiche, Djilali
    Flament, Stephane
    2023 IEEE SENSORS, 2023,
  • [9] Engineering Controllable Architecture in Matrigel for 3D Cell Alignment
    Jang, Jae Myung
    Si-Hoai-Trung Tran
    Na, Sang Cheol
    Jeon, Noo Li
    ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (04) : 2183 - 2188
  • [10] CHALLENGES IN 3D CELL CULTURE: VALIDATION OF CELL VIABILITY ASSAYS IN 3D BRAIN TUMOUR MODEL
    Vaezzadeh, Mahsa
    Heng, Benjamin
    Guller, Anna
    Guillemin, Gilles J.
    Nadort, Annemarie
    TISSUE ENGINEERING PART A, 2022, 28 : S620 - S621