Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity

被引:117
|
作者
Nichols, JF
Morgan, CG
Sarkin, JA
Sallis, JF
Calfas, KJ
机构
[1] San Diego State Univ, Dept Exercise & Sport Sci, San Diego, CA 92182 USA
[2] San Diego State Univ, Dept Psychol, San Diego, CA 92182 USA
来源
关键词
exercise; energy expenditure; physical activity monitors;
D O I
10.1097/00005768-199906000-00022
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The purposes of this study were to assess the validity and reliability of the Tritrac R3D accelerometer during treadmill walking and running and then to calibrate the instrument. Methods: The Tritrac was assessed on 60 young adults (23.4 +/- 2.9 yr) during treadmill walking and running at 3.2, 6.4, and 9.7 km.h(-1). The calibration was carried out by identifying ranges of Tritrac raw data (vector magnitude) values corresponding to light (2-3.9 MET), moderate (4-7 MET), and vigorous (>7 MET) physical activity. Energy expenditure (EE), measured by indirect calorimetry, served as the criterion measure. Results: Interinstrument intraclass reliability coefficients for Tritracs worn on the right and left hip ranged from 0.73-0.87, while intersession coefficients demonstrated high reliability for all speeds (R = 0.87-0.92). Paired t-tests comparing mean accelerometer counts at 6.4 km.h(-1), 0% grade (2647 +/- 456), and 6.4 km.h(-1), 5% grade (2635 +/- 435) demonstrated no significant difference (P > 0.05). Mean differences between EE measured by indirect calorimetry and that estimated by the Tritrac ranged from 0.0082 kcal.kg(-1).min(-1) at 3.2 km.h(-1) to 0.0320 kcal.kg(-1).min(-1) at 9.7 km.h(-1), with the Tritrac consistently overestimating EE during horizontal treadmill walking. The relationship between vector magnitude and EE across all speeds was highly linear (R-2 = 0.90, SEE = 0.014 kcal.kg(-1).min(-1)), with little overlap between light, moderate, and vigorous categories. The mean vector magnitudes at 2, 4, and 7 MET were 650, 1772, and 3455, respectively. Conclusions: These data indicate that the Tritrac is highly reliable from day to day and is sensitive to changes in speed but not grade. Furthermore, the Tritrac accurately distinguishes various intensities of walking and jogging on level ground. With limitations, these cut-points can be used to categorize light, moderate, and vigorous physical activity and to estimate EE.
引用
收藏
页码:908 / 912
页数:5
相关论文
共 50 条
  • [1] Youth recall and TriTrac accelerometer estimates of physical activity levels
    Cradock, AL
    Wiecha, JL
    Peterson, KE
    Sobol, AM
    Colditz, GA
    Gortmaker, SL
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (03): : 525 - 532
  • [2] Reliability and validity of the Tritrac-R3D accelerometer during backpacking: A case study
    DeVoe, D
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2001, 72 (01) : A21 - A21
  • [3] The reliability, validity, and stability of a measure of physical activity in the elderly
    Kochersberger, G
    McConnell, E
    Kuchibhatla, MN
    Pieper, C
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (08): : 793 - 795
  • [4] Calibration of raw accelerometer data to measure physical activity: A systematic review
    Mendes, Marcio de Almeida
    da Silva, Inacio C. M.
    Ramires, Virgilio V.
    Reichert, Felipe F.
    Martins, Rafaela C.
    Tomasi, Elaine
    [J]. GAIT & POSTURE, 2018, 61 : 98 - 110
  • [5] Reliability and validity of the Tritrac-R3D accelerometer during backpacking: A case study
    DeVoe, D
    Dalleck, L
    [J]. PERCEPTUAL AND MOTOR SKILLS, 2001, 93 (01) : 37 - 46
  • [6] Reliability and validity testing of a single-item physical activity measure
    Milton, K.
    Bull, F. C.
    Bauman, A.
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2011, 45 (03) : 203 - 208
  • [7] Reliability and validity of a single-item physical activity measure for adolescents
    Scott, Joseph J.
    Morgan, Philip J.
    Plotnikoff, Ronald C.
    Lubans, David R.
    [J]. JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2015, 51 (08) : 787 - 793
  • [8] Coupling GPS with Accelerometer to Measure Physical Activity
    Rosli, Mohd Hafiz
    Baharuldin, Mohamad Taufik Hidayat
    Abdullah, Muhammad Nazrul Hakim
    Fauzee, Mohd Sofian Omar
    Adam, Yunus
    Yaacob, Azhar
    [J]. PSU-USM INTERNATIONAL CONFERENCE ON HUMANITIES AND SOCIAL SCIENCES, 2013, 91 : 171 - 178
  • [9] Reliability and Validity Testing of the Physical Resilience Measure
    Resnick, Barbara
    Galik, Elizabeth
    Dorsey, Susan
    Scheve, Ann
    Gutkin, Susan
    [J]. GERONTOLOGIST, 2011, 51 (05): : 643 - 652
  • [10] Reliability and validity of a GPS-enabled iPhoneTM "app" to measure physical activity
    Benson, Amanda Clare
    Bruce, Lyndell
    Gordon, Brett Ashley
    [J]. JOURNAL OF SPORTS SCIENCES, 2015, 33 (14) : 1421 - 1428