NDE EVALUATION OF THE INTERGRANULAR CORROSION SUSCEPTIBILITY OF A 2205 DUPLEX STAINLESS STEEL USING THERMOELECTRIC POWER AND DOUBLE LOOP ELECTROCHEMICAL POTENTIOKINETIC REACTIVATION METHODS

被引:1
|
作者
Ortiz, N. [1 ]
Carreon, H. [1 ]
Ruiz, A. [1 ]
机构
[1] Univ Michoacana, Inst Invest Met, Michoacana, Mexico
关键词
Duplex Stainless Steel; DOS; Intergranular Corrosion; Thermoelectric Power;
D O I
10.1063/1.4789188
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
There is a need for a nondestructive technique to assess rapidly and with confidence the degree of sensitization (DOS) in duplex stainless steel (DSS). In this investigation, we present the use of thermoelectric power (TEP) measurements as nondestructive method for the determination of DOS in isothermally aged 2205 DSS at 700 degrees C for different aging times. The DOS of the aged samples was first established by performing the double loop electrochemical potentiokinetic reactivation (DL-EPR) test. The microstructural evolution was evaluated by scanning electron microscopy (SEM). Experimental results indicate that TEP coefficient is sensitive to gradual microstructural changes produced by thermal aging and can be used to monitor IGC sensitization of 2205 duplex stainless steel.
引用
收藏
页码:1264 / 1269
页数:6
相关论文
共 47 条
  • [1] Double loop electrochemical potentiokinetic reactivation test optimization in checking of duplex stainless steel intergranular corrosion susceptibility
    Amadou, T
    Braham, C
    Sidhom, H
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2004, 35A (11): : 3499 - 3513
  • [2] Double loop electrochemical potentiokinetic reactivation test optimization in checking of duplex stainless steel intergranular corrosion susceptibility
    T. Amadou
    H. Sidhom
    C. Braham
    Metallurgical and Materials Transactions A, 2004, 35 : 3499 - 3513
  • [3] Evaluation by the Double Loop Electrochemical Potentiokinetic Reactivation Test of Aged Ferritic Stainless Steel Intergranular Corrosion Susceptibility
    H. Sidhom
    T. Amadou
    C. Braham
    Metallurgical and Materials Transactions A, 2010, 41 : 3136 - 3150
  • [4] Evaluation by the Double Loop Electrochemical Potentiokinetic Reactivation Test of Aged Ferritic Stainless Steel Intergranular Corrosion Susceptibility
    Sidhom, H.
    Amadou, T.
    Braham, C.
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2010, 41A (12): : 3136 - 3150
  • [5] Evaluation of intergranular corrosion susceptibility of UNS S31803 duplex stainless steel with an optimized double loop electrochemical potentiokinetic reactivation method
    Gong, Jia
    Jiang, Y. M.
    Deng, B.
    Xu, J. L.
    Hu, J. P.
    Li, Jin
    ELECTROCHIMICA ACTA, 2010, 55 (18) : 5077 - 5083
  • [6] Evaluation of aged duplex stainless steel UNS S32750 susceptibility to intergranular corrosion by optimized double loop electrochemical potentiokinetic reactivation method
    Hong, Jufeng
    Han, Dong
    Tan, Hua
    Li, Jin
    Jiang, Yiming
    CORROSION SCIENCE, 2013, 68 : 249 - 255
  • [7] DETERMINATION OF INTERGRANULAR CORROSION SUSCEPTIBILITY OF Z3CN20.09M CAST DUPLEX STAINLESS STEEL BY A MODIFIED DOUBLE LOOP ELECTROCHEMICAL POTENTIOKINETIC REACTIVATION METHOD
    Shi, Y. Z.
    Yang, B.
    Zhang, M. X.
    Wu, H. C.
    Wang, S. L.
    ENERGY MATERIALS CONFERENCE PROCEEDINGS 2014, 2014, : 557 - 562
  • [8] Intergranular Corrosion of Low Cr Ferritic Stainless Steel 429 Evaluated by the Optimized Double Loop Electrochemical Potentiokinetic Reactivation Test
    Li, Xiao-lei
    Ni, Yi-fan
    Jiang, Yi-ming
    Li, Jin
    Li, Li
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2015, 2015
  • [9] Investigation on ultra-pure ferritic stainless steel 436L susceptibility to intergranular corrosion using optimised double loop electrochemical potentiokinetic reactivation method
    Sun, Jiakun
    Sun, Li
    Dai, Nianwei
    Li, Jin
    Jiang, Yiming
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 53 (08) : 574 - 581
  • [10] Sensitization phenomena on aged SAF 2205 duplex stainless steel and their control using the electrochemical potentiokinetic reactivation test
    Angelini, E
    De Benedetti, B
    Maizza, G
    Rosalbino, F
    CORROSION, 1999, 55 (06) : 606 - 615