Enterprise 2 Stent-Assisted Embolization of Paraclinoid Aneurysms: A Single Center Preliminary Study

被引:1
|
作者
Wu, Degang [1 ]
Lai, Niansheng [1 ]
Zhao, Xintong [1 ]
Liu, Jiaqiang [1 ]
Li, Zhenbao [1 ]
Fang, Xinggen [1 ]
机构
[1] Wannan Med Coll, Yijishan Hosp, Dept Neurosurg, Translat Res Inst Neurol Disorders,Affiliated Hosp, Wuhu, Peoples R China
关键词
Enterprise; 2; stent; paraclinoid aneurysms; embolization; preliminary study; INTERNAL CAROTID-ARTERY; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; APPOSITION; COILING; RISK;
D O I
10.2147/CIA.S390882
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Objective: Enterprise stent has been widely used for assisted embolization in wide-necked aneurysms while delayed ischemia or thromboembolic complications for its incomplete stent apposition. The purpose of this study was to summarize and analyze the clinical experience of using Enterprise 2 (EP2) stent-assisted embolization in the treatment of paraclinoid aneurysms. Methods: From January 2019 to December 2020, the clinical and imaging data of 98 patients with paraclinoid aneurysms treated with EP2 stent-assisted embolization were enrolled retrospectively. Preliminary experience and follow-up outcomes of EP2 stent-assisted embolization of paraclinoid aneurysms were assessed by using the Raymond grade and modified Rankin Scale. Results: Of the 98 aneurysms, all stents were released satisfactorily. The immediate postprocedural angiography revealed a complete occlusion of the aneurysms with 77.55% of the (76/98) patients, and the last follow-up angiograms showed complete occlusion with 83.67% of the (82/98) patients. The average aneurysm size was (4.11 +/- 1.25) mm, the aneurysm diameter was (4.41 +/- 1.37) mm, the vessel radius was (3.87 +/- 0.32) mm, the diameter at the distal of stent was (3.23 +/- 0.21) mm, and the proximal was (4.18 +/- 0.23) mm. Among the 98 aneurysms, 13 cases had incomplete stent apposition, 3 cases had intraoperative knotting, and the stents were improved post adjusted; 2 cases had vasospasm and 1 case had stenosis during operation, the symptoms were improved after symptomatic treatment. The result demonstrated that stent length and inner bending radius of parent artery were the pivotal factors affecting Conclusion: The EP2 stent for the treatment of paraclinoid aneurysms is safe and effective, however, the length of the stent and the inner bending radius of parent artery are important factors affecting incomplete stent apposition.
引用
收藏
页码:1833 / 1840
页数:8
相关论文
共 50 条
  • [1] Predictors of recurrence after stent-assisted coil embolization of paraclinoid aneurysms
    Lv, Nan
    Zhao, Rui
    Yang, Pengfei
    Fang, Yibin
    Li, Qiang
    Xu, Yi
    Hong, Bo
    Zhao, Wenyuan
    Liu, Jianmin
    Huang, Qinghai
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 33 : 173 - 176
  • [2] Stent-assisted coil embolization of intracranial aneurysms: A single center experience
    Luo, Chao-Bao
    Teng, Michael Mu-Huo
    Chang, Feng-Chi
    Lin, Chung-Jung
    Guo, Wan-Yuo
    Chang, Cheng-Yen
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2012, 75 (07) : 322 - 328
  • [3] Simple Coiling versus Stent-Assisted Coiling of Paraclinoid Aneurysms : Radiological Outcome in a Single Center Study
    Kim, Soo Yeon
    Park, Dong Sun
    Park, Hye Yin
    Chun, Young Il
    Moon, Chang Taek
    Roh, Hong Gee
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2017, 60 (06) : 644 - 653
  • [4] Overlapping stent-assisted coil embolization for vertebrobasilar dissecting aneurysms: a single-center study
    Shi, Guangyao
    Xu, Shancai
    Gareev, Ilgiz
    Ji, Zhiyong
    Pei, Wu
    Zhang, Guang
    Qi, Jingtao
    Chen, Rui
    Liang, Shaodong
    Gu, Yan
    Wang, Chunlei
    NEUROLOGICAL RESEARCH, 2021, 43 (09) : 701 - 707
  • [5] Stent-assisted coiling of paraclinoid aneurysms: risks and effectiveness
    Ogilvy, Christopher S.
    Natarajan, Sabareesh K.
    Jahshan, Shady
    Karmon, Yuval
    Yang, Xinyu
    Snyder, Kenneth V.
    Hopkins, L. Nelson
    Siddiqui, Adnan H.
    Levy, Elad I.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2011, 3 (01) : 14 - 20
  • [6] Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization
    Liu, Jian
    Jing, Linkai
    Wang, Chao
    Paliwal, Nikhil
    Wang, Shengzhang
    Zhang, Ying
    Xiang, Jianping
    Siddiqui, Adnan H.
    Meng, Hui
    Yang, Xinjian
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (11) : 1140 - 1147
  • [7] Effects of Enterprise 2 stent-assisted coil embolization for wide-necked intracranial aneurysms
    Zhou Y.
    Peng Q.
    Mu S.
    Chinese Neurosurgical Journal, 8 (1)
  • [8] Effects of Enterprise 2 stent-assisted coil embolization for wide-necked intracranial aneurysms
    Zhou Yangyang
    Peng Qichen
    Mu Shiqing
    中华神经外科杂志(英文), 2023, (01)
  • [9] Therapeutic effect of enterprise stent-assisted embolization for very small ruptured intracranial aneurysms
    Qin, Feiyun
    Li, Zhenbao
    Fang, Xinggen
    Zhao, Xintong
    Liu, Jiaqiang
    Wu, Degang
    Lai, Niansheng
    MEDICINE, 2017, 96 (34)
  • [10] Stent-assisted embolization of recurrent or residual intracranial aneurysms
    Olli I. Tähtinen
    Hannu I. Manninen
    Ritva L. Vanninen
    Riitta Rautio
    Arto Haapanen
    Janne Seppänen
    Tero Niskakangas
    Jaakko Rinne
    Leo Keski-Nisula
    Neuroradiology, 2013, 55 : 1221 - 1231