Umbilical flow distribution to the liver and the ductus venosus: An in vitro investigation of the fluid dynamic mechanisms in the fetal sheep

被引:46
|
作者
Kiserud, T [1 ]
Stratford, L [1 ]
Hanson, MA [1 ]
机构
[1] UCL, SCH MED, DEPT OBSTET & GYNAECOL, LONDON W1N 8AA, ENGLAND
基金
英国惠康基金;
关键词
fetal sheep circulation; umbilical vein; liver; ductus venosus; blood flow;
D O I
10.1016/S0002-9378(97)70442-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVES: The study aimed to determine whether an inherent difference in Vascular resistance between the liver and the ductus venosus influences the distribution of umbilical blood to the two sections of the circulation. STUDY DESIGN: Flow was measured in vitro in six fetal sheep liver preparations, perfused at varying pressures with saline solution or with blood of hematocrit 25% to 26% or 41% to 42%, with an occluded or open ductus venosus, at a temperature of 19 degrees C to 21 degrees C with likely absence of local control mechanisms. RESULTS: There was a linear relationship between pressure and flow through the liver, except at very low pressures when the linearity was broken. A closing pressure of 1 to 4 mm Hg was noted, lowest with saline solution and highest with hematocrit 42%. An open ductus venosus reduced overall resistance and brought down the closing pressure to <1 mm Hg. This also occurred during perfusion with high hematocrit. Thus at low pressures a proportionally greater fraction of umbilical flow was directed through the ductus venosus. CONCLUSIONS: The different physical properties of the portal vasculature and of the ductus venosus, pressure and viscosity, have a substantial impact on distribution of umbilical flow to the two parts of the circulation. Reduced umbilical venous pressure and increased hematocrit favor an increased fraction of flow through the ductus venosus.
引用
收藏
页码:86 / 90
页数:5
相关论文
共 24 条
  • [1] UMBILICAL BLOOD-FLOW TO LIVER AND DUCTUS VENOSUS IN FETAL LAMBS INUTERO
    EDELSTONE, D
    HEYMANN, MA
    RUDOLPH, AM
    CIRCULATION, 1977, 56 (04) : 133 - 133
  • [2] LIVER AND DUCTUS VENOSUS FLOW IN FETAL LAMBS
    EDELSTONE, DI
    HEYMANN, MA
    RUDOLPH, AM
    GYNECOLOGIC INVESTIGATION, 1977, 8 (1-2): : 105 - 105
  • [3] EFFECTS OF HYPOXEMIA AND DECREASING UMBILICAL FLOW ON LIVER AND DUCTUS VENOSUS BLOOD FLOWS IN FETAL LAMBS
    EDELSTONE, DI
    RUDOLPH, AM
    HEYMANN, MA
    AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (05): : H656 - H663
  • [4] Ductus venosus agenesis prevents transmission of central venous pulsations to the umbilical vein in fetal sheep
    Kiserud, T
    Crowe, C
    Hanson, M
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (03) : 190 - 194
  • [5] Distribution of ductus venosus blood flow using computational fluid dynamics on fetal heart virtual models
    Anzia, Lucille E.
    Pewowaruk, Ryan
    Ruedinger, Katrina L.
    Trampe, Barbara
    Heiser, Timothy
    Roldan-Alzate, Alejandro
    Iruretagoyena, J. Igor
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (01) : S591 - S592
  • [6] Quantitative Evaluation of Umbilical Venous Blood Flow through the Ductus Venosus and Its Distribution to Fetal Organs during Labor
    Tiso, Giulia C.
    Bellotti, Maria
    Garo, Chiara
    Marconi, Anna Maria
    REPRODUCTIVE SCIENCES, 2014, 21 (03) : 83A - 83A
  • [7] THE EFFECT OF NOREPINEPHRINE ON BLOOD-FLOW THROUGH THE FETAL LIVER AND DUCTUS VENOSUS
    ZINK, J
    VANPETTEN, GR
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 137 (01) : 71 - 77
  • [8] EFFECT OF NOREPINEPHRINE ON BLOOD-FLOW THROUGH FETAL LIVER AND DUCTUS VENOSUS
    ZINK, J
    VANPETTEN, GR
    FEDERATION PROCEEDINGS, 1978, 37 (03) : 615 - 615
  • [9] Numerical investigation of the haemodynamics in the human fetal umbilical vein/ductus venosus based on the experimental data
    Rezaee, Taraneh
    Hassani, Kamran
    BIOSCIENCE REPORTS, 2016, 36
  • [10] Umbilical flow distribution to the liver and the ductus venosus in human fetuses during gestation: an anatomy-based mathematical modeling
    Pennati, G
    Corno, C
    Costantino, ML
    Bellotti, M
    MEDICAL ENGINEERING & PHYSICS, 2003, 25 (03) : 229 - 238