Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ENEA-INMRI, Italy and the BIPM in low-energy x-rays

被引:3
|
作者
Burns, D. T. [1 ]
Kessler, C. [1 ]
Roger, P. [1 ]
Toni, M. P. [2 ]
Pinto, M. [2 ]
Bovi, M. [2 ]
Cappadozzi, G. [2 ]
Silvestri, C. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Ist Nazl Metrol Radiaz Ionizzanti, Rome, Italy
关键词
D O I
10.1088/0026-1394/48/1A/06010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A key comparison has been made between the air-kerma standards of the ENEA-INMRI, Italy and the BIPM in the low-energy x-ray range. The results show the standards to be in agreement at the level of the standard uncertainty for the comparison of 1.9 parts in 10(3). No significant trend with radiation quality is observed. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Key comparison BIPM.RI(I)-K7 of the air-kerma standards of the ENEA-INMRI, Italy and the BIPM in mammography x-rays
    Kessler, C.
    Burns, D.
    Roger, P.
    Toni, M. P.
    Pinto, M.
    Bovi, M.
    Cappadozzi, G.
    Silvestri, C.
    [J]. METROLOGIA, 2015, 52
  • [2] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ARPANSA and the BIPM in low-energy x-rays
    Burns, D. T.
    Lye, J. E.
    Kessler, C.
    Roger, P.
    Butler, D. J.
    [J]. METROLOGIA, 2010, 47
  • [3] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NMIJ and the BIPM in low-energy x-rays
    Burns, D. T.
    Nohtomi, A.
    Saito, N.
    Kurosawa, T.
    Takata, N.
    [J]. METROLOGIA, 2008, 45
  • [4] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the GUM, Poland and the BIPM in low-energy x-rays
    Burns, D. T.
    Roger, P.
    Knyziak, A. B.
    [J]. METROLOGIA, 2012, 49
  • [5] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the PTB, Germany and the BIPM in low-energy x-rays
    Burns, D. T.
    Kessler, C.
    Bueermann, L.
    [J]. METROLOGIA, 2014, 51
  • [6] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NIM, China, and the BIPM in low-energy x-rays
    Burns, D. T.
    Kessler, C.
    Wu Jinjie
    Wang Peiwei
    [J]. METROLOGIA, 2019, 56 (1A)
  • [7] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NMIJ, Japan and the BIPM in low-energy x-rays
    Burns, D. T.
    Kessler, C.
    Tanaka, T.
    Kurosawa, T.
    Saito, N.
    [J]. METROLOGIA, 2015, 52
  • [8] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the VSL, Netherlands and the BIPM in low-energy x-rays
    Burns, D. T.
    Kessler, C.
    de Prez, L.
    Joulaeizadeh, L.
    [J]. METROLOGIA, 2014, 51
  • [9] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the BFKH, Hungary, and the BIPM in low-energy x-rays
    Burns, D.T.
    Kessler, C.
    Finta, V.
    [J]. Metrologia, 2023, 60 (1 A)
  • [10] Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the GUM, Poland, and the BIPM in low-energy x-rays
    Burns, D.T.
    Kessler, C.
    Michalik, L.
    [J]. Metrologia, 2022, 59 (1 A)