The prognostic accuracy of different QT interval measures

被引:0
|
作者
Lund, K
Perkiömäki, JS
Brohet, C
Elming, H
Zaïdi, M
Torp-Pedersen, C
Huikuri, HV
Nygaard, H
Pedersen, AK
机构
[1] Skejby Univ Hosp, Dept Cardiol, DK-8200 Aarhus N, Denmark
[2] Oulu Univ Hosp, Dept Cardiol, Oulu, Finland
[3] Catholic Univ Louvain, St Luc Hosp, Dept Cardiol, Brussels, Belgium
[4] Dept Cardiol, Hellerup, Denmark
关键词
QT; electrophysiology; sudden death; prognostic accuracy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The QT intervals accuracy for predicting arrhythmic death varies between studies, possibly due to differences in the selection of the lead used for measurement of the QT interval. The purpose of this study was to analyze the prognostic accuracy of all known ways to select the lead. Methods and Results: Three institutions that used different methods for measuring QT intervals provided their QT databases. They included more than 3500 twelve-lead surface ECGs. The data represented low- and high-risk patients of the normal population (survivors vs dead from cardiovascular causes), acute myocardial infarction (survivors versus death from all causes) and remote myocardial infarction (with vs without a history of ventricular arrhythmia). The prognostic accuracy was defined as the area under the Receiver Operator Curve (ROC-area). The most accurate standard leads were I and aVL and the least accurate was AVR. The most accurate precordial lead was V,. The prognostic accuracy of the longest QT interval was higher than for any standard lead. The prognostic accuracy of the mean of the three longest QT intervals was equal to or slightly lower than for the longest QT interval. Conclusions: The highest prognostic accuracy is obtained with the longest QT interval. The accuracies of the lead selection methods are so different that it can explain a substantial part of the differences between otherwise similar studies in the literature. We recommend the use of the mean value of the three longest QT intervals.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 50 条
  • [1] Automated QT interval analysis with confidence measures
    Hughes, NP
    Tarassenko, L
    [J]. COMPUTERS IN CARDIOLOGY 2004, VOL 31, 2004, 31 : 765 - 768
  • [2] Repeated-measures models in the analysis of QT interval
    Dmitrienko, A
    Smith, B
    [J]. PHARMACEUTICAL STATISTICS, 2003, 2 (03) : 175 - 190
  • [3] Different species require different correction factors for the QT interval
    Soloviev, Maxim V.
    Hamlin, Robert L.
    Barrett, Randy M.
    Chengelis, Christopher P.
    Schaefer, Gerald J.
    [J]. CARDIOVASCULAR TOXICOLOGY, 2006, 6 (02) : 145 - 157
  • [4] Different species require different correction factors for the QT interval
    Maxim V. Soloviev
    Robert L. Hamlin
    Randy M. Barrett
    Christopher P. Chengelis
    Gerald J. Schaefer
    [J]. Cardiovascular Toxicology, 2006, 6 : 145 - 157
  • [5] Course and prognostic implications of QT interval and QT interval variability after primary coronary angioplasty in acute myocardial infarction
    Bonnemeier, H
    Hartmann, F
    Wiegand, UKH
    Bode, F
    Katus, HA
    Richardt, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) : 44 - 50
  • [6] QT interval correction in LBBB: Improving the accuracy of an imperfect measurement
    Abu-El-Haija, Basil
    Mounsey, J. Paul
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (06) : 690 - 691
  • [7] Prognostic significance of prolonged corrected QT interval in cerebral contusion
    Yavuz, Ahmed Yasin
    Baskurt, Ozan
    Kurtulus, Yunus
    Avci, Idris
    [J]. INDIAN JOURNAL OF MEDICAL RESEARCH, 2023, 158 (02) : 175 - 181
  • [8] On the accuracy of different measures of q
    Erickson, Timothy
    Whited, Toni M.
    [J]. FINANCIAL MANAGEMENT, 2006, 35 (03) : 5 - 33
  • [9] The prognostic value of the QT interval and QT interval dispersion in all-cause and cardiac mortality and morbidity in a population of Danish citizens
    Elming, H
    Holm, E
    Jun, L
    Torp-Pedersen, C
    Kober, L
    Kircshoff, M
    Malik, M
    Camm, J
    [J]. EUROPEAN HEART JOURNAL, 1998, 19 (09) : 1391 - 1400
  • [10] Accuracy of QT interval measurement on electrocardiographs displayed on electronic 'smart' devices
    Rotella, Joe-Anthony
    Taylor, David McD
    Wong, Anselm
    Greene, Shaun L.
    [J]. EMERGENCY MEDICINE AUSTRALASIA, 2016, 28 (02) : 187 - 192