A Review of Condition Monitoring of Underground Power Cables

被引:0
|
作者
Khan, Ammar Anwar [1 ]
Malik, Nazar [1 ]
Al-Arainy, Abdulrehman [1 ]
Alghuwainem, Saad [1 ]
机构
[1] King Saud Univ, Coll Engn, Dept Elect Engn, Saudi Aramco Chair Elect Power, Riyadh, Saudi Arabia
关键词
power cables; condition monitoring; partial discharge; medium voltage; PARTIAL DISCHARGE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power distribution system relies heavily on a vast network of medium voltage (MV) underground cables for power delivery. Condition monitoring technologies can, therefore, play a vital role in attempting to target the cables that pose the most urgent reliability concerns. Maintaining or increasing a power system's reliability at minimal cost is an important issue for most network owners. Condition monitoring gives the information needed for safe and reliable operation, replacement strategy and hence increases the system reliability. Demands for reliable power causes a growing tendency to apply different strategies in the form of condition based maintenance. Partial discharge (PD) monitoring is one of the successful diagnostic tools for accessing the insulation condition of MV cables. Data acquired by online PD measurements can help in identifying the upcoming faults in such cable networks and possibly forecast the remaining life of the insulation. This paper reviews the condition monitoring and diagnostictechniques used forunderground power cables.
引用
收藏
页码:909 / 912
页数:4
相关论文
共 50 条
  • [1] Condition Monitoring of Underground Power Cables Via Power-Line Modems and Anomaly Detection
    Yeganejou, Mojtaba
    Ryan, Tessa
    Reshadi, Mohammadhossein
    Dick, Scott
    Lipsett, Michael G.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (01) : 3 - 12
  • [2] MONITORING AND RATING OF UNDERGROUND POWER-CABLES
    PATTON, RN
    KIM, SK
    PODMORE, R
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (06): : 2285 - 2293
  • [3] Online Condition Monitoring of Partial Discharge in HV Underground Cables
    Ayub, A. S.
    Siew, W. H.
    Soraghan, J. J.
    [J]. 2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 966 - 969
  • [4] A Condition Indexing for Assessment Management in MV Underground Power Cables
    Lee, Seung-Won
    Kim, Su-Hwan
    Kim, Yong-Hyun
    Lim, Jang-Seob
    Lee, Jin
    Noh, Sung-Ho
    Kim, Tae-Wan
    [J]. 2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 655 - 658
  • [5] Considerations for Advanced Temperature Monitoring of Underground Power Cables
    Bascom, Earle C. , III
    Clairmont, Bernie
    [J]. 2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [6] UNDERGROUND POWER CABLES
    ENDACOTT, JD
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1973, 275 (1248): : 193 - 203
  • [7] Thermal Analysis of Underground Power Cables-A Monitoring Procedure
    Mariut, Larisa
    Helerea, Elena
    Lungoci, Gavril
    Abagiu, Sorin
    [J]. 2012 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2012,
  • [8] A Novel FEF Method for Insulation Status Monitoring of Underground Power Cables
    Dian, Songyi
    Liang, Mengyu
    Lou, Bingwu
    Liu, Tao
    [J]. JOURNAL OF COMPUTERS, 2013, 8 (02) : 441 - 447
  • [9] History of Underground Power Cables
    Orton, Harry
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2013, 29 (04) : 52 - 57
  • [10] Review of Underground Storage Tank Condition Monitoring Techniques
    Ooi, Ching Sheng
    Ngui, Wai Keng
    Hui, Kar Hoou
    Lim, Meng Hee
    Leong, Mohd. Salman
    [J]. ENGINEERING APPLICATION OF ARTIFICIAL INTELLIGENCE CONFERENCE 2018 (EAAIC 2018), 2019, 255