Indoor air quality in printing press in Kuwait

被引:4
|
作者
Al-Awadi, L. [1 ]
Al-Rashidi, M. [1 ]
Pereira, B. [1 ]
Pillai, A. [1 ]
Khan, A. [1 ]
机构
[1] Kuwait Inst Sci Res, Environm & Life Sci Res Ctr, POB 24885, Safat 13109, Kuwait
关键词
Printing press; Indoor air quality; Volatile organic compounds; CO2; Sick building syndrome; VOLATILE ORGANIC-COMPOUNDS; OCCUPATIONAL-EXPOSURE; POLLUTANTS; SCHOOLS;
D O I
10.1007/s13762-018-1800-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The well-being of the workers in any place is the main health goal of any office; thereby, this study has focused on the printing press due to the inadequate indoor air quality. Most of the pollutants are emitted from the storage, use and disposal of chemicals and liquid/solid waste. Printing inks, toner and cartridges contain volatile organic components that have the potential to generate odors and can cause serious health risk. The press is located in a separate building, away from the main work area containing administration and laboratories. The press is responsible for various tasks, from visiting cards to conferences proceedings. Air quality inside the printing press has been assessed taking into consideration associated offices, administration, editing, printing and publications sections, and heating ventilation and air conditioning (HVAC) system performance was evaluated through continuous monitoring of temperature, humidity and carbon dioxide (CO2) levels. The assessment of the indoor air quality in printing press was completed by accurate measurements of volatile organic compounds (VOCs), CO2, temperature, humidity, ozone and particulate matters. These measured values were compared with national and international guidelines set for an acceptable indoor air quality. The results will be used for the identification of sources, which can be implemented in mitigation strategies to abate the prevalence of sick building syndrome if exists. Samples taken for 8 working hours revealed VOCs levels approached 7.72ppm where 33.82% contribution was from halogenated compounds where predominant compound was refrigerant trichlorofloromethane (R-11) leaked from refrigeration loop of HVAC system, followed by oxygenated group 25.84% mainly consisting of methyl tertiary butyl ether common additive of gasoline emitted from light vehicles. Aliphatic group constituted 25.62% of TVOC, where predominant compound was solvent cyclohexane, and aromatic group was the least 14.72% of the TVOC consisting of toluene common thinner.
引用
收藏
页码:2643 / 2656
页数:14
相关论文
共 50 条
  • [1] Indoor air quality in printing press in Kuwait
    L. Al-Awadi
    M. Al-Rashidi
    B. Pereira
    A. Pillai
    A. Khan
    [J]. International Journal of Environmental Science and Technology, 2019, 16 : 2643 - 2656
  • [2] Dust Events and Indoor Air Quality in Residential Homes in Kuwait
    Yuan, Yufei
    Alahmad, Barrak
    Kang, Choong-Min
    Al-Marri, Fhaid
    Kommula, Venkateswarlu
    Bouhamra, Walid
    Koutrakis, Petros
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (07)
  • [3] Indoor air quality investigation from screen printing industry
    Kiurski, Jelena S.
    Maric, Branislav B.
    Aksentijevic, Snezana M.
    Oros, Ivana B.
    Kecic, Vesna S.
    Kovacevic, Ilija M.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 28 : 224 - 231
  • [4] Evaluation of the Indoor Air Quality in Governmental Oversight Supermarkets (Co-Ops) in Kuwait
    Almutairi, Azel
    Alsanad, Abdullah
    Alhelailah, Heba
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (22):
  • [5] Estimation of optimum requirements for indoor air quality and energy consumption in some residences in Kuwait
    Elkilani, A
    Bouhamra, W
    [J]. ENVIRONMENT INTERNATIONAL, 2001, 27 (06) : 443 - 447
  • [6] Assessment of indoor air quality in comparison using air conditioning and fan system in printing premise
    Ramlan, Nazirah
    Ahmad, Siti Nurhalimatul Husna
    Aminuddin, Eeydzah
    Hamid, Hazrul Abdul
    Yaman, Siti Khalijah
    Abdullah, Abd Halid
    [J]. SRIWIJAYA INTERNATIONAL CONFERENCE ON ENGINEERING, SCIENCE AND TECHNOLOGY (SICEST 2016), 2017, 101
  • [7] On indoor air pollution and indoor air quality control
    Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment, Chongqing University, Chongqing 400045, China
    不详
    [J]. Chongqing Jianzhu Daxue Xuebao, 2007, 6 (108-112):
  • [8] Indoor air quality
    [J]. 1998, (71):
  • [9] Indoor air quality
    Youakim, Sami
    [J]. BRITISH COLUMBIA MEDICAL JOURNAL, 2019, 61 (03): : 131 - 131
  • [10] Indoor air quality
    Ding, T.
    Liu, Z.
    [J]. Livestock Environment VII, Proceedings, 2005, : 257 - 262