A Self-Adaptive Digital Calibration Technique for Multi-Channel High Resolution Capacitive SAR ADCs

被引:0
|
作者
Lyu, Binbin [1 ,2 ]
Lu, Wengao [1 ,2 ]
Yang, Sijia [1 ,2 ]
Chen, Zhongjian [1 ,2 ]
Zhang, Yacong [1 ,2 ]
机构
[1] Peking Univ, Inst Microelect, Key Lab Microelect Devices & Circuits, Beijing 100871, Peoples R China
[2] Peking Univ, Informat Technol Inst, Tianjin Binhai, Tianjin 300452, Peoples R China
关键词
SAR ADC; multi-channel; digital calibration;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a self-adaptive digital technique to calibrate multi-channel SAR ADCs. Rather than achieving higher resolution by adjusting the analog component values, this new digital method infers the capacitor weights of a SAR ADC with the help of a channel-shared high resolution sigma-delta ADC, which results in remarkable improvements in the capacitive SAR ADCs' property. ENOB increases from 11.06 bits to 12.67 bits. The digital calibration logic is based on LMS (least mean squares) and gradient descent.
引用
收藏
页码:730 / 733
页数:4
相关论文
共 50 条
  • [1] A Self-Adaptive Capacitive Compensation Technique for Body Channel Communication
    Mao, Jingna
    Yang, Huazhong
    Lian, Yong
    Zhao, Bo
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (05) : 1001 - 1012
  • [2] A Self-Testing Platform with a Foreground Digital Calibration Technique for SAR ADCs
    Juan, Yi-Hsiang
    Huang, Hong-Yi
    Lee, Shuenn-Yuh
    Lai, Shin-Chi
    Juang, Wen-Ho
    Luo, Ching-Hsing
    APPLIED SCIENCES-BASEL, 2016, 6 (08):
  • [3] A Capacitor Self-Calibration Technique for High Resolution ADCs
    Cao, Yitong
    Lu, Wengao
    Li, Kezhi
    Liu, Zhaokai
    Chen, Zhongjian
    Zhang, Yacong
    2016 13TH IEEE INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUIT TECHNOLOGY (ICSICT), 2016, : 915 - 917
  • [4] Analysis and Calibration of Nonbinary-Weighted Capacitive DAC for High-Resolution SAR ADCs
    Zhang, Dai
    Alvandpour, Atila
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2014, 61 (09) : 666 - 670
  • [5] INVESTIGATIONS ON THE INTERNAL CALIBRATION OF MULTI-CHANNEL SAR
    Younis, M.
    Rommel, T.
    de Almeida, F.
    Huber, S.
    Martone, M.
    Villano, M.
    Krieger, G.
    2017 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2017, : 5386 - 5389
  • [6] Sampling Time Calibration Method for Multi-Channel Interleaved ADCs
    Leuciuc, Adrian
    2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017, : 108 - 111
  • [7] A New Interface Technique for the Acquisition of Multiple Multi-Channel High Speed ADCs
    Calvet, Denis
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2592 - 2597
  • [8] A low-cost digital-domain foreground calibration for high resolution SAR ADCs
    Guan, Rui
    Jin, Jing
    Zhou, Jianjun
    MICROELECTRONICS JOURNAL, 2018, 73 : 86 - 93
  • [9] Analysis and Cancellation of Crosstalk in Multi-Channel Pipelined-SAR ADCs
    Wu, Yimin
    Lu, Wenhan
    Ye, Fan
    Ren, Junyan
    2022 11TH INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS (ICCCAS 2022), 2022, : 136 - 139
  • [10] AN INTERNAL INSTRUMENT CALIBRATION SIMULATOR FOR MULTI-CHANNEL SAR
    Younis, Marwan
    de Almeida, Felipe Queiroz
    Huber, Sigurd
    Laux, Christopher
    Martone, Michele
    Villano, Michelangelo
    Krieger, Gerhard
    IGARSS 2018 - 2018 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2018, : 9201 - 9203