Microelectrode miRNA Sensors Enabled by Enzyme less Electrochemical Signal Amplification

被引:63
|
作者
Wang, Tanyu [1 ,2 ]
Viennois, Emilie [2 ,3 ]
Merlin, Didier [2 ,3 ]
Wang, Gangli [1 ]
机构
[1] Georgia State Univ, Dept Chem, Atlanta, GA 30302 USA
[2] Georgia State Univ, Ctr Diagnost & Therapeut, Inst Biomed Sci, Atlanta, GA 30302 USA
[3] Atlanta Vet Affairs Med Ctr, Decatur, GA 30033 USA
基金
美国国家卫生研究院;
关键词
CONICAL NANOPORES; MICRORNA; EXPRESSION; CANCER; QUANTIFICATION; BIOMARKERS; ELECTROCATALYSIS; HYBRIDIZATION; STABILITY; BIOSENSOR;
D O I
10.1021/acs.analchem.5b00780
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Better detections of circulating microRNAs (miRNAs) as disease biomarkers could advance diseases diagnosis and treatment. Current analysis methods or sensors for research and applications are challenged by the low concentrations and wide dynamic range (from aM to nM) of miRNAs in a physiological sample. Here, we report a one-step label-free electrochemical sensor comprising a triple-stem DNA-redox probe structure on a gold microelectrode. A new signal amplification mechanism without the need of a redox enzyme is introduced. The novel strategy overcomes the fundamental limitations of microelectrode DNA sensors that fail to generate detectable current, which is primarily due to the limited amount of redox probes in response to the target analyte binding. By employing a reductant, tris(2-carboxyethyl) phosphine hydrochloride (TCEP) in the detection buffer solution, each redox molecule on the detection probe is cyclically oxidized at the electrode and reduced by the reductant; thus, the signal is amplified in situ during the detection period. The combined merits in the diagnosis power of cyclic voltammetry and the high sensitivity of pulse voltammetry enable parallel analysis for method validation and optimization previously inaccessible. As such, the detection limit of miRNA-122 was 0.1 fM via direct readout, with a wide detection range from sub fM to nM. The detection time is within minutes, which is a significant improvement over other macroscopic sensors and other relevant techniques such as quantitative reverse transcription polymerase chain reaction (qRT-PCR). The high selectivity of the developed sensors is demonstrated by the discrimination against two most similar family sequences: miR-122-3p present in serum and 2-mismatch synthetic RNA sequence. Interference such as nonspecific adsorption, a common concern in sensor development, is reduced to a negligible amount by adopting a multistep surface modification strategy. Importantly, unlike qRT-PCR, the microelectrochemical sensor offers direct absolute quantitative readout that is amenable to clinical and in-home point-of-care (POC) applications. The sensor design is flexible, capable of being tailored for detection of different miRNAs of interest. Combined with the fact that the sensor was constructed at microscale, the method can be generalized for high throughput detection of miRNA signatures as disease biomarkers.
引用
收藏
页码:8173 / 8180
页数:8
相关论文
共 50 条
  • [1] Ultrasensitive electrochemical detection of miRNA based on polymerization signal amplification
    Wang, Qingyu
    Sun, Haobo
    Wen, Dongxiao
    Wang, Lei
    Li, Lianzhi
    Kong, Jinming
    Zhang, Xueji
    TALANTA, 2021, 235
  • [2] Understanding signal amplification strategies of nanostructured electrochemical sensors for environmental pollutants
    Gan, Xiaorong
    Zhao, Huimin
    CURRENT OPINION IN ELECTROCHEMISTRY, 2019, 17 : 56 - 64
  • [3] High-performance and versatile electrochemical aptasensor based on self-supported nanoporous gold microelectrode and enzyme-induced signal amplification
    Shi, Lei
    Rong, Xiaojiao
    Wang, Yan
    Ding, Shiming
    Tang, Wanying
    BIOSENSORS & BIOELECTRONICS, 2018, 102 : 41 - 48
  • [4] Electrochemical sensors based on interdigitated microelectrode arrays
    Fiaccabrino, GC
    Strike, DJ
    deRooji, NF
    KoudelkaHep, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 26 - IEC
  • [5] OPPORTUNITIES FOR ELECTROCHEMICAL SENSORS USING MICROELECTRODE DEVICES
    KITTLESEN, GP
    WHITE, HS
    WRIGHTON, MS
    PAUL, E
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1984, 131 (08) : C322 - C322
  • [6] Microelectrode Array Signal Amplification Using Stochastic Resonance
    Barreto, Marco Antonio
    Fambrini, Francisco
    Saito, Jose Hiroki
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 2030 - 2035
  • [7] Molecular Imprint for Electrochemical Detection of Streptomycin Residues Using Enzyme Signal Amplification
    Que, Xiaohua
    Liu, Bingqian
    Fu, Libing
    Zhuang, Junyang
    Chen, Guonan
    Tang, Dianping
    ELECTROANALYSIS, 2013, 25 (02) : 531 - 537
  • [8] A Novel Electrochemical Enzyme-linked Immunosensor Based on Tyramine Signal Amplification
    Liu Meng-Qin
    Jiang Jian-Hui
    Feng Yun-Lan
    Huang Yong
    Shen Guo-Li
    Yu Ru-Qin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (02) : 258 - 262
  • [9] Dual signal amplification strategy for enzyme-free electrochemical detection of microRNAs
    Wu, Xiaoyan
    Chai, Yaqin
    Yuan, Ruo
    Zhuo, Ying
    Chen, Ying
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 : 296 - 302
  • [10] Sensitive SERS detection of miRNA via enzyme-free DNA machine signal amplification
    Li, Xiaoxiao
    Ye, Sujuan
    Luo, Xiliang
    CHEMICAL COMMUNICATIONS, 2016, 52 (67) : 10269 - 10272