Experimental validation of finite element model for proximal composite femur using optical measurements

被引:66
|
作者
Grassi, Lorenzo [1 ,2 ]
Vaananen, Sami P. [3 ]
Yavari, Saber Amin [4 ]
Weinans, Harrie [4 ,5 ]
Jurvelin, Jukka S. [3 ]
Zadpoor, Amir A. [4 ]
Isaksson, Hanna [1 ,2 ]
机构
[1] Lund Univ, Div Solid Mech, Lund, Sweden
[2] Lund Univ, Dept Orthoped, Lund, Sweden
[3] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
[4] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Delft, Netherlands
[5] Erasmus MC, Dept Orthoped, Rotterdam, Netherlands
基金
瑞典研究理事会; 芬兰科学院;
关键词
Digital image correlation; Composite femur; Finite element; Bone fracture; DIGITAL-IMAGE-CORRELATION; STRAIN DISTRIBUTION; HIP-FRACTURES; BONE; OSTEOPOROSIS; ACCURACY; STRENGTH; MECHANICS; DENSITY; WOMEN;
D O I
10.1016/j.jmbbm.2013.02.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used data from strain gages to validate the model, thus having up to 15 experimental measurements. Optical techniques, such as digital image correlation, can help to improve the models by providing a continuous field of deformation data over a femoral surface. The main objective of this study was to validate finite element models of six composite femora against strain data from digital image correlation, obtained during fracture tests performed in quasi-axial loading configuration. The finite element models were obtained from CT scans, by means of a semi-automatic segmentation. The principal strains both during the elastic phase and close to the fracture were compared, and showed a correlation coefficient close to 0.9. In the linear region, the slope and intercept were close to zero and unity, while for the case when fracture load was simulated, the slope decreased somewhat. The accuracy of the obtained results is comparable with the state-of-the-art literature, with the significant improvement of having around 50,000 data points for each femur. This large number of measurements allows a more comprehensive validation of the predictions by the finite element models, since thousand of points are tracked along the femoral neck and trochanter region, i.e., the sites that are most critical for femur fracture. Moreover, strain measurement biases due to the strain gage reinforcement effect, were avoided. The combined experimental numerical approach proved to be ready for application to in-vitro tests of human cadaver femurs, thus helping to develop a suitable mechanistic fracture risk criterion. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 50 条
  • [1] Experimental Validation of a Finite Element Model of the Proximal Femur Using Digital Image Correlation and a Composite Bone Model
    Dickinson, A. S.
    Taylor, A. C.
    Ozturk, H.
    Browne, M.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (01):
  • [2] Experimental validation of a voxel-based finite element model simulating femoroplasty of lytic lesions in the proximal femur
    Amelie Sas
    An Sermon
    G. Harry van Lenthe
    [J]. Scientific Reports, 12
  • [3] Experimental validation of a finite element model of a composite tibia
    Gray, H. A.
    Zavatsky, A. B.
    Taddei, F.
    Cristofolini, L.
    Gill, H. S.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H3) : 315 - 324
  • [4] Experimental validation of a voxel-based finite element model simulating femoroplasty of lytic lesions in the proximal femur
    Sas, Amelie
    Sermon, An
    van Lenthe, G. Harry
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] Validation of a parametric finite element human femur model
    Klein, Katelyn F.
    Hu, Jingwen
    Reed, Matthew P.
    Schneider, Lawrence W.
    Rupp, Jonathan D.
    [J]. TRAFFIC INJURY PREVENTION, 2017, 18 (04) : 420 - 426
  • [6] Biomechanical Finite Element Method Model of the Proximal Carpal Row and Experimental Validation
    Marques, Rafael
    Melchor, Juan
    Sanchez-Montesinos, Indalecio
    Roda, Olga
    Rus, Guillermo
    Hernandez-Cortes, Pedro
    [J]. FRONTIERS IN PHYSIOLOGY, 2022, 12
  • [7] Development of a parametric finite element model of the proximal femur using statistical shape and density modelling
    Nicolella, Daniel P.
    Bredbenner, Todd L.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (02) : 101 - 110
  • [8] A finite element study of the developing proximal femur
    Ribble, TG
    Santare, MH
    Miller, F
    [J]. PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 497 - 499
  • [9] Experimental validation of intact and implanted distal femur finite element models
    Completo, A.
    Fonseca, F.
    Simoes, J. A.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (11) : 2467 - 2476
  • [10] Experimental Validation of Finite Element Models of the Proximal Tibia Using Digital Volume Correlation
    Zaluski, Dylan
    Kontulainen, Saija
    Johnston, James
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2020, 35 : 66 - 67