A cryptate reference electrode for ionic liquids

被引:18
|
作者
Lewandowski, Andrzej [1 ]
Osinska, Monika [1 ]
Swiderska-Mocek, Agnieszka [1 ]
Galinski, Maciej [1 ]
机构
[1] Poznan Univ Tech, Fac Chem Technol, PL-60965 Poznan, Poland
关键词
reference electrode; ionic liquid; molecular liquid; cryptand;
D O I
10.1002/elan.200804267
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The cryptate electrode (Ag/Ag(+)222), prepared by immersing silver wire in a solution of silver(I) salt and the cryptand 222 (4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo[8.8.8]hexacosane) in ionic liquids have been studied. The potential of the electrode is stabilized by the equilibrium of the Ag+ ion complexation by the cryptand, similarly to the potential stabilization by the ionic product of slightly soluble salts, used in aqueous electrodes of the second kind. The Ag/Ag(+)222 cryptate electrode (concentration of the cryptate was much higher than the silver(I) cation concentration, [222] > [Ag+]) may be used as a reference electrode in room temperature ionic liquids. The potential of the Ag/Ag(+)222 electrode is less sensitive to the presence of impurities, such as halides or water, in comparison to the Ag/Ag+ electrode. After anodic or cathodic polarization, the potential of the Ag/Ag(+)222 electrode comes back to the initial open circuit potential quickly. Preparation of the Ag/Ag(+)222 reference electrode is very easy: a silver wire is immersed in a solution of Ag+ salt and cryptand 222 (both available commercially) in the ionic liquid under study.
引用
下载
收藏
页码:1903 / 1908
页数:6
相关论文
共 50 条
  • [1] Reference electrode for ionic liquids
    Saheb, A
    Janata, J
    Josowicz, M
    ELECTROANALYSIS, 2006, 18 (04) : 405 - 409
  • [2] Reference electrode for use in ionic liquids
    Saheb, Amir H.
    Janata, Jiri A.
    Josowicz, Mira
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [3] Reference electrode for ionic liquids (vol 18, pg 405, 2006)
    Saheb, Amir
    Janata, Jiri
    Josowicz, Mira
    ELECTROANALYSIS, 2007, 19 (11) : 1222 - 1222
  • [4] Electrode screening by ionic liquids
    Lynden-Bell, R. M.
    Frolov, A. I.
    Fedorov, M. V.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2012, 14 (08) : 2693 - 2701
  • [5] Electrode reactons in ionic liquids
    Matyushov, Dmitry
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [6] PTFE Bound Activated Carbon - A Quasi Reference Electrode for Ionic Liquids and its Application
    Weingarth, D.
    Foelske-Schmitz, A.
    Wokaun, A.
    Koetz, R.
    MOLTEN SALTS AND IONIC LIQUIDS 18, 2012, 50 (11): : 111 - 117
  • [7] Evaluation of a Ag|Ag+ reference electrode for use in room temperature ionic liquids
    Snook, G. A.
    Best, A. S.
    Pandolfo, A. G.
    Hollenkamp, A. F.
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (09) : 1405 - 1411
  • [8] PTFE bound activated carbon-A quasi-reference electrode for ionic liquids
    Weingarth, D.
    Foelske-Schmitz, A.
    Wokaun, A.
    Koetz, R.
    ELECTROCHEMISTRY COMMUNICATIONS, 2012, 18 : 116 - 118
  • [9] The use of the reference electrode equipped with an ionic liquid salt bridge in electrochemistry of ionic liquids: A convenient way to align the formal potentials of redox reactions in ionic liquids based on the standard hydrogen electrode scale
    Kakiuchi, Takashi
    Domae, Shota
    Miyadi, Taishi
    Kibi, Kaito
    Yamamoto, Masahiro
    ELECTROCHEMISTRY COMMUNICATIONS, 2021, 126
  • [10] Redox reference systems in ionic liquids
    De Vreese, Peter
    Haerens, Kurt
    Matthijs, Edward
    Binnemans, Koen
    ELECTROCHIMICA ACTA, 2012, 76 : 242 - 248