Stability indicating validated HPLC method for quantification of levothyroxine with eight degradation peaks in the presence of excipients

被引:29
|
作者
Shah, R. B. [1 ]
Bryant, A. [1 ]
Collier, J. [1 ,2 ]
Habib, M. J. [2 ]
Khan, M. A. [1 ]
机构
[1] US FDA, Div Prod Qual Res, Off Testing & Res, Off Pharmaceut Sci,Ctr Drug Evaluat & Res, Rockville, MD 20857 USA
[2] Howard Univ, Dept Pharmaceut Sci, Sch Pharm, Washington, DC 20059 USA
关键词
levothyroxine; impurities; degradation products; validation; excipients;
D O I
10.1016/j.ijpharm.2008.04.018
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A simple, sensitive, accurate, and robust stability indicating analytical method is presented for identification, separation, and quantitation Of L-thyroxine and eight degradation impurities with an internal standard. The method was used in the presence of commonly used formulation excipients such as butylated hydroxyanisole, povidone, crospovidone, croscarmellose sodium, mannitol, sucrose, acacia, lactose monohydrate, confectionary sugar, microcrystalline cellulose, sodium laurel sulfate, magnesium stearate, talc, and silicon dioxide. The two active thyroid hormones: 3,3',5,5'-tetra-iodO-L-thyronine (Lthyroxine-T4) and 3,3',5-tri-iodO-L-thyronine J3) and degradation products including di-iodothyronine J2), thyronine (TO), tyrosine (Tyr), di-iodotyrosine (DIT), mono-iodotyrosine (MIT), 3,3',5,5'-tetraiodothyroacetic acid J4AA) and 3,31,5-tri-iodothyroacetic acid (T3AA) were assayed by the current method. The separation Of L-thyroxine and eight metabolites along with theophylline (internal standard) was achieved using a C18 column (25oC) with a mobile phase of trifluoroacetic acid (0.1%, v/v, pH 3)-acetonitrile in gradient elution at 0.8 ml/min at 223 nnn. The sample diluent was 0.01 M methanolic NaOH. Method was validated according to FDA, USP, and ICH guidelines for inter-day accuracy, precision, and robustness after checking performance with system suitability. Tyr (4.97 min), theophylline (9.09 min), MIT (9.55 min), DIT (11.37 min), TO (11.63 min), T2 (14.47 min), T3 (16.29 min), T4 (17.60 min), T3AA (22.71 min), and T4AA (24.83 min) separated in a single chromatographic run. Linear relationship (r2 > 0.99) was observed between the peak area ratio and the concentrations for all of the compounds within the range of 2-20 I.Lg/ml. The total time for analysis, equilibration and recovery was 40 min. The method was shown to separate well from commonly employed formulation excipients. Accuracy ranged from 95 to 105% for T4 and 90 to 110% for all other compounds. Precision was <2% for all the compounds. The method was found to be robust with minor changes in injection volume, flow rate, column temperature, and gradient ratio. Validation results indicated that the method shows satisfactory linearity, precision, accuracy, and ruggedness and also stress degradation studies indicated that the method can be used as stability indicating method for L-thyroxine in the presence of excipients. Published by Elsevier B.V.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [1] Validated Stability-Indicating HPLC Method for the Determination of Mesna in Presence of Its Degradation Products
    Rizk, Mohamed
    Taha, Elham A.
    Mowaka, Shereen
    Abdallah, Youmna M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (05) : 742 - 748
  • [2] Determination of Dapiprazole Hydrochloride in the Presence of Process and Degradation Impurities by a Validated Stability Indicating RP-HPLC Method
    Prasanthi, K. Jaya
    Sundar, B. Syama
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (09) : 4820 - 4824
  • [3] A Validated Stability-Indicating LC Method for Orbifloxacin in the Presence of Degradation Products
    Cazedey, Edith C. L.
    Othman, Asma
    Garg, Sanjay
    Salgado, Herida R. N.
    CURRENT PHARMACEUTICAL ANALYSIS, 2011, 7 (03) : 176 - 181
  • [4] Isolation and characterization of a degradation product in leflunomide and a validated selective stability-indicating HPLC-UV method for their quantification
    Balraj Saini
    Gulshan Bansal
    Journal of Pharmaceutical Analysis, 2015, 5 (03) : 207 - 212
  • [5] VALIDATED STABILITY INDICATING HPLC METHOD FOR ESTIMATION OF CAPECITABINE
    Lalitha, K., V
    Reddy, J. Raveendra
    Devanna, N.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (11): : 5651 - 5658
  • [6] Stability Indicating Validated HPLC Method for Simultaneous Quantification of Nitazoxanide and Ofloxacin in Pharmaceutical Dosage Form
    Rakibe, Udaykumar
    Ahirrao, Vinod
    Yeole, Ravindra
    Wakte, Pravin
    LATIN AMERICAN JOURNAL OF PHARMACY, 2018, 37 (01): : 29 - 36
  • [7] Validated Stability Indicating HPLC Method for the Quantification of Process Related Impurities of Ubrogepant in Pharmaceutical Formulations
    Nagababu, Uppu
    Sujatha, D.
    Jyothi, Uppalapati
    Vissa, Manikyala Rao
    Kumar, B. Srinivasa
    EURASIAN JOURNAL OF CHEMISTRY, 2023, 109 (01): : 31 - 40
  • [8] Kinetic study of the alkaline degradation of imidapril hydrochloride using a validated stability indicating HPLC method
    Abdulla, Shabaan A.
    Frag, Eman Y.
    Ahmed, Heba E.
    RSC ADVANCES, 2016, 6 (73) : 69239 - 69250
  • [9] Stress Degradation Studies on Cefpodoxime Proxetil and Development of a Validated Stability-Indicating HPLC Method
    Patel, G.
    Rajput, S.
    ACTA CHROMATOGRAPHICA, 2011, 23 (02) : 215 - 234
  • [10] Greens appraisal of validated stability indicating RP-HPLC method and forced degradation study for quantification of Ebastine in wastewater and dosage form
    Almalki, Manal A.
    Alanazi, Tahani Y. A.
    Mahgoub, Samar M.
    El-Ela, Fatma I. Abo
    Mohamed, Mahmoud A.
    ANNALES PHARMACEUTIQUES FRANCAISES, 2024, 82 (03): : 420 - 432