Damage tolerance of an anchor head in a post-tensioning anchorage system

被引:3
|
作者
Gálvez, JC
Elices, M
Olivares, MA
机构
[1] Univ Politecn Madrid, Dept Ingn Civil Construct, ETSI Caminos Panales & Puertos, E-28040 Madrid, Spain
[2] Univ Politecn Madrid, Dept Ciencia Mat, ETSI Caminos Panales & Puertos, E-28040 Madrid, Spain
[3] Univ Castilla La Mancha, Dept Mecan Aplicada & Ingn Proyectos, E-13071 Ciudad Real, Spain
关键词
damage tolerance; stress intensity factors; design; defects; structural integrity;
D O I
10.1016/j.engfailanal.2005.01.012
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The use of the damage tolerance concept is growing in the design of civil engineering structures. The aim of this paper is to provide some guides to help designing anchorages according to the damage tolerance concept. The paper shows the importance of the small defects, idealized like small cracks, in the structural integrity of these elements. The stress intensity factors (SIF) induced by small cracks in an anchor head of post-tensioned strand anchorage system are calculated. The study includes the evaluation of the influence of the shape and dimensions of the anchor head on the SIF. The numerical predictions are compared with experimental results of 1/2 scaled specimens of poly-methyl-methacrylate. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 246
页数:12
相关论文
共 50 条
  • [1] WEDGE ANCHORAGE SYSTEM FOR STRAND POST-TENSIONING
    SCHECHTE.E
    BOECKER, HC
    [J]. JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1971, 16 (04): : 49 - &
  • [2] The efficiency of confinement reinforcement in post-tensioning anchorage zones
    Rebelo, Jorge
    Marchao, Carla
    Lucio, Valter
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2021, 73 (06) : 271 - 287
  • [3] The application of external post-tensioning system to a damage masonry arch
    Zampieri, Paolo
    Piazzon, Riccardo
    Ferroni, Riccardo
    Pellegrino, Carlo
    [J]. XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 605 - 609
  • [4] BURSTING STRESS DISTRIBUTION OF THE POST-TENSIONING ANCHORAGE ZONE ACCORDING TO THE SHAPE OF ANCHORAGE
    Kim, Jin-Kook
    Lee, Pil-Goo
    Kwak, Hyo-Gyoung
    Kwon, Yang-Soo
    [J]. FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 411 - 414
  • [5] POST-TENSIONING
    HANUSCHAK, W
    [J]. CIVIL ENGINEERING, 1983, 53 (03): : 30 - 30
  • [6] POST-TENSIONING SYSTEM SURVEILLANCE PROGRAM
    DREW, GE
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1979, 105 (02): : 347 - 357
  • [7] High Tensile Bond Anchorage for Post-tensioning Bar Tendon Systems
    Loeffler, Kay
    Birckel, Thomas
    [J]. HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 2451 - 2457
  • [8] Optimized post-tensioning anchorage in prestressed concrete I-beams
    Ma, ZG
    Saleh, MA
    Tadros, MK
    [J]. PCI JOURNAL, 1999, 44 (02): : 56 - +
  • [9] Validation of post-tensioning anchorage zones by laboratory testing and numerical simulation
    Cervenka, Vladimir
    Ganz, Hans Rudolf
    [J]. STRUCTURAL CONCRETE, 2014, 15 (02) : 258 - 268
  • [10] A Local Compression Tests of UHPC Anchor Blocks for Post-Tensioning Tendons
    Choi, Eun Suk
    Lee, Jung Woo
    Joh, Changbin
    Kwark, Jong Won
    Kim, Jee Sang
    Choi, Yoon Seok
    [J]. ADVANCES IN FRACTURE AND DAMAGE MECHANICS XI, 2013, 525-526 : 561 - +