The novel haptic-twist method for a sutureless double-needle intrascleral haptic fixation technique

被引:4
|
作者
Erakgun, Tansu [1 ]
Gobeka, Hamidu Hamisi [2 ]
机构
[1] Kaskaloglu Eye Hosp, Izmir, Turkey
[2] Dept Ophthalmol, Fac Med, Erzurum Yolu 4 Km, TR-04100 Agri, Turkey
关键词
Aphakia; Haptic-twist method; Intrascleral haptic fixation; Secondary IOL implantation; Trailing haptic; INTRAOCULAR-LENS IMPLANTATION; SCLERAL FIXATION; CAPSULAR SUPPORT; VISUAL OUTCOMES; EYES; ABSENCE; DESIGN;
D O I
10.1007/s10792-021-01862-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Description of a novel modified technique known as haptic-twist method for placing a trailing haptic into a 27 G needle during double-needle intrascleral haptic fixation (Yamane technique) in the absence and/or inadequacy of capsular support. Methods The trailing haptic was threaded into the needle lumen using a haptic-twist method in 12 eyes of 11 patients with aphakia. The haptic was grasped by a forceps 2-3 mm from the tip, while the forceps was rotated by 180 degrees counter-clockwise around its own axis. This maneuver enabled the trailing haptic to be slightly twisted without any deformation and to coordinate with the needle in the proper angle. The surgical technique has also been mentioned in a surgical video. Results Mean age of the patients was 62 years +/- 18 (range 46-78 years). Although the mean pre-operative best-corrected visual acuity was 0.70 +/- 0.35 logarithm of the minimum angle of resolution (logMAR) (range 1.30-0.20 logMAR), an improvement of up to 0.40 +/- 0.32 logMAR (range 1.0-0.1 logMAR) was observed 3 months after surgery. No trailing haptic bending or breakage was observed during the process. Furthermore, no optical tilting or decentralization was observed post-operatively. Conclusions Although threading the leading haptic into the needle is reasonably straightforward, the trailing haptic positioning can be difficult due to an inappropriate gesture of both the haptic and the needle. We fervently believe that this novel haptic-twist method can provide a much simpler and easier approach, and thus contribute to better surgical outcomes.
引用
收藏
页码:3013 / 3020
页数:8
相关论文
共 47 条
  • [1] The novel haptic-twist method for a sutureless double-needle intrascleral haptic fixation technique
    Tansu Erakgun
    Hamidu Hamisi Gobeka
    International Ophthalmology, 2021, 41 : 3013 - 3020
  • [2] Trailing-haptic-first modification of double-needle intrascleral haptic fixation technique
    Kim, Dooho Brian
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04): : 424 - 428
  • [3] Outcomes of the flanged intrascleral haptic fixation with double-needle technique in patients with Marfan syndrome
    Tao, Yunhan
    Ren, Xiang
    Zhang, Yifan
    Gao, Yuzhu
    Tao, Mengying
    Gou, Yueqin
    Gao, Yunxia
    Zhang, Ming
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (04) : 2166 - 2172
  • [4] Double-Needle Haptic Repositioning: A Troubleshooting Technique for Flanged Intraocular Lens Fixation
    Hung, Jia-Horung
    Wang, Li-An
    Hsu, Shu-Hsien
    Hsu, Sheng-Min
    Yamane, Shin
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (12): : 2064 - 2067
  • [5] Transconjunctival intrascleral intraocular lens fixation with double-needle and flanged-haptic technique: Ultrathin line between success and failure
    Turnbull, Andrew M. J.
    Lash, Stephen C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1843 - 1844
  • [6] Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique
    Yamane, Shin
    Sato, Shimpei
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    OPHTHALMOLOGY, 2017, 124 (08) : 1136 - 1142
  • [7] Intrascleral haptic fixation for haptic exposure after Yamane technique
    Asif, Mohamed Ibrahime
    Bafna, Rahul Kumar
    Kapoor, Anirudh
    Sharma, Namrata
    BMJ CASE REPORTS, 2021, 14 (08)
  • [8] Combined double-needle flanged-haptic intrascleral fixation of an intraocular lens and Descemet-stripping endothelial keratoplasty
    Cervantes, Lorenzo J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (05): : 593 - 596
  • [9] Exposure of haptic of posterior chamber intraocular lens after sutureless intrascleral fixation
    Matsui, Yoshitsugu
    Matsubara, Hisashi
    Hanemoto, Tsukasa
    Kondo, Mineo
    BMC OPHTHALMOLOGY, 2015, 15
  • [10] Exposure of haptic of posterior chamber intraocular lens after sutureless intrascleral fixation
    Yoshitsugu Matsui
    Hisashi Matsubara
    Tsukasa Hanemoto
    Mineo Kondo
    BMC Ophthalmology, 15