Microbial contamination in dental unit waterlines:: Comparison between Er:YAG laser and turbine lines

被引:0
|
作者
Sacchetti, Rossella [1 ]
Baldissarri, Augusto [1 ]
De Luca, Giovanna [1 ]
Lucca, Paola [1 ]
Stampi, Serena [1 ]
Zanetti, Franca [1 ]
机构
[1] Univ Bologna, Dept Med & Publ Hlth, Sez Igiene, Div Hyg, I-40126 Bologna, Italy
关键词
dental unit; Er : YAG laser; water; turbine lines; microbial contamination;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The investigation was carried out by evaluating the microbiological characteristics of the water before and after treatment with Er:YAG laser and turbine. The study was carried out in 2 dental surgeries. In both cases the laser and dental units were served by two independent circuits, fed by the same potable tap water. Samples were taken from the water supplying and the water leaving the turbine and laser before and after treatment on the same patient. Total heterotrophic plate count was measured at 36 degrees C and at 22 degrees C, and the presence of Staphylococcus species and non-fermenting Gram negative bacteria was investigated. Bacterial contamination was found within the circuit, especially in the laser device. Pseudomonas aeruginosa was detected in only I sample of supply water, in 11.1% and in 19.4% of the samples from the turbine and the laser respectively. No evidence of Staphylococcus aureus was found. The contamination of supply water was low, whereas that of the water leaving the handpieces of the 2 devices was high, especially in the laser. Attention should be paid to the control of the water leaving laser devices, given the increasingly wide use of such instruments in dental treatment exposed to risk of infection.
引用
收藏
页码:275 / 279
页数:5
相关论文
共 50 条
  • [1] MICROBIAL CONTAMINATION OF DENTAL UNIT WATERLINES
    Szymanska, Jolanta
    Sitkowska, Jolanta
    Dutkiewicz, Jacek
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2008, 15 (02) : 173 - 179
  • [2] Microbial contamination of dental unit waterlines
    Souza-Gugelmin, MCM
    Lima, SNM
    Lima, CDT
    Mian, H
    Ito, LY
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1070 - 1070
  • [3] Microbial contamination of dental unit waterlines in Istanbul, Turkey
    Duygu Göksay
    Ayşın Çotuk
    Zuhal Zeybek
    Environmental Monitoring and Assessment, 2008, 147 : 265 - 269
  • [4] Microbial contamination of dental unit waterlines: the scientific argument
    Pankhurst, CL
    Johnson, NW
    Woods, RG
    INTERNATIONAL DENTAL JOURNAL, 1998, 48 (04) : 359 - 368
  • [5] Microbial contamination of dental unit waterlines in Istanbul, Turkey
    Goksay, Duygu
    Cotuk, Aysun
    Zeybek, Zuhal
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 147 (1-3) : 265 - 269
  • [6] MICROBIAL CONTAMINATION OF DENTAL UNIT WATERLINES IN BUSHEHR, IRAN
    Dobaradaran, Sina
    Nabipour, Iraj
    Ramavandi, Bahman
    Zazouli, Mohammad Ali
    Tahmasebi, Rahim
    Ghaedi, Hossein
    Bahreini, Masoud
    Sirouss, Mehrandokht
    FRESENIUS ENVIRONMENTAL BULLETIN, 2014, 23 (04): : 1000 - 1005
  • [7] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Duygu Göksay Kadaifciler
    Aysin Cotuk
    Environmental Monitoring and Assessment, 2014, 186 : 3431 - 3444
  • [8] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Kadaifciler, Duygu Goksay
    Cotuk, Aysin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (06) : 3431 - 3444
  • [9] Bacterial contamination of dental unit waterlines
    Szymanska, Jolanta
    Sitkowska, Jolanta
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (05) : 3603 - 3611
  • [10] Bacterial contamination of dental unit waterlines
    Jolanta Szymańska
    Jolanta Sitkowska
    Environmental Monitoring and Assessment, 2013, 185 : 3603 - 3611