Study on the effect of blood scattering on the variety of equivalent path-length in dynamic spectra measurement

被引:0
|
作者
Wang Yan
Li Gang [1 ]
Lin Ling
Liu Yu-liang
Li Xiao-xia
机构
[1] Tianjin Univ, Coll Precis Instruments & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Liaoning Tech Univ, Fuxin 123000, Peoples R China
[3] Hebei Univ Technol, Sch Elect & Automat Engn, Tianjin 300130, Peoples R China
关键词
dynamic spectrum; Monte Carlo simulations; scattering; mean path length; non-invasive; blood component;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Dynamic spectrum (DS) can be used to eliminate the individual discrepancy of tissues theoretically except the pulsatile component of the artery blood (PCAB). One of the systematic errors in the calculation of the component changes from NIRS data of the dynamic spectrum is the absolute magnitudes and relative differences in path-length factors as a function of wavelength. Monte Carlo simulations are used in the present paper to examine the importance and mitigation methods of this error while the photoelectric pulse wave is detected on the finger tip. The measure accuracy of the DS method is evaluated by error analysis.
引用
收藏
页码:91 / 94
页数:4
相关论文
共 13 条
  • [1] ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT
    DELPY, DT
    COPE, M
    VANDERZEE, P
    ARRIDGE, S
    WRAY, S
    WYATT, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12): : 1433 - 1442
  • [2] BOUNDARY-CONDITIONS FOR THE DIFFUSION EQUATION IN RADIATIVE-TRANSFER
    HASKELL, RC
    SVAASAND, LO
    TSAY, TT
    FENG, TC
    MCADAMS, MS
    TROMBERG, BJ
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (10) : 2727 - 2741
  • [3] HEISE HM, 2000, IN VIVO ASSAY ENCY A
  • [4] Jacques S.L., 1995, OPTICAL THERMAL RESP, P73, DOI [10.1007/978-1-4757-6092-7_4, DOI 10.1007/978-1-4757-6092-7_4]
  • [5] Measurement of lactate in whole human blood with near-infrared transmission spectroscopy
    Lafrance, D
    Lands, LC
    Burns, DH
    [J]. TALANTA, 2003, 60 (04) : 635 - 641
  • [6] Li G, 2004, PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, P875
  • [7] Qi XM, 2003, SPECTROSC SPECT ANAL, V23, P870
  • [8] SMITH AC, 2000, US BANCORP PIPER JAI
  • [9] Evaluation of selectivity and robustness of near-infrared glucose measurements based on short-scan Fourier transform infrared interferograms
    Wabomba, MJ
    Small, GW
    Arnold, MA
    [J]. ANALYTICA CHIMICA ACTA, 2003, 490 (1-2) : 325 - 340
  • [10] MCML - MONTE-CARLO MODELING OF LIGHT TRANSPORT IN MULTILAYERED TISSUES
    WANG, LH
    JACQUES, SL
    ZHENG, LQ
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1995, 47 (02) : 131 - 146