Image quality and dose assessment of collimator slit width effect in SLOT-SCAN X-ray imaging system

被引:7
|
作者
Hossein, Mohammadi [1 ]
Reza, Shojaei Mohammad [1 ]
Jamshid, Soltani-Nabipour [2 ]
机构
[1] Shahrood Univ Technol, Dept Phys, Shahrood, Iran
[2] Islamic Azad Univ, Parand Branch, Fac Comp & IT, Dept Phys, Parand, Iran
关键词
Slot-scan imaging system; Gate simulation; DQE; Image quality; DIGITAL RADIOGRAPHY; MAMMOGRAPHY; SIMULATION; SELENIUM; NOISE; MTF;
D O I
10.1016/j.apradiso.2021.109642
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The effect of collimator slit width on patient absorbed dose and image quality is evaluated in the SLOT-SCAN imaging system. For this purpose, GATE Monte-Carlo code was used for simulation. To determine contrast to noise ratio (CNR), copper filters with different thicknesses were used and a 2mm lead filter was applied for the determination of the Modulation Transfer Function (MTF) and Detective Quantum Efficiency (DQE). Spatial resolution was determined by using line-pairs per millimeter test. In addition, the anthropomorphic digital Zubal phantom was used to estimate the patient absorbed dose. As the results showed, the CNR shows 77% reduction by decreasing the collimator slit width from 4 mm to 0.4 mm. Other parameters such as DQE and spatial resolution showed to be constant. Finally, whole-body patient absorbed dose estimation resulted in reduction of 14 times using the 0.4 mm collimator slit. The results showed that decreasing the slit width reduced the patient absorbed dose without any significant change in the image quality.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Slot-Scan Dual-Energy Measurement of Bone Mineral Density on a Robotic X-Ray System
    Zhao, C.
    Luckner, C.
    Herbst, M.
    Vogt, S.
    Ritschl, L.
    Kappler, S.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [2] X-RAY BACKSCATTER IMAGING WITH A NOVEL TWISTED SLIT COLLIMATOR
    Osterloh, Kurt
    Zscherpel, Uwe
    Jechow, Mirko
    Fratzscher, Daniel
    Wrobel, Norma
    Ewert, Uwe
    10TH EUROPEAN CONFERENCE ON NON-DESTRUCTIVE TESTING 2010 (ECNDT), VOLS 1-5, 2010, : 1031 - 1038
  • [3] Slot-scan dual-energy bone densitometry using motorized X-ray systems
    Zhao, Chumin
    Herbst, Magdalena
    Weber, Thomas
    Luckner, Christoph
    Vogt, Sebastian
    Ritschl, Ludwig
    Kappler, Steffen
    Siewerdsen, Jeffrey H.
    Zbijewski, Wojciech
    MEDICAL PHYSICS, 2021, 48 (11) : 6673 - 6695
  • [4] Slot-Scan Digital Radiography of the Lower Extremities: a Comparison to Computed Radiography with Respect to Image Quality and Radiation Dose
    Lee, Kwang Hwi
    Kwon, Jong Won
    Yoon, Young Cheol
    Choi, Sang-Hee
    Jung, Jee Young
    Kim, Ji Hye
    Lee, Sang Jun
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (01) : 51 - 57
  • [5] COMPACT X-RAY COLLIMATOR DESIGN YIELDING GOOD IMAGE QUALITY WITH LOW PATIENT DOSE
    CARSON, AN
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (03) : 373 - 373
  • [6] Investigation of Radiation Dose and Image Quality in X-Ray Radiographic Imaging
    Zainon, Rafidah
    Abu Talib, Nor Syazreena
    Abu Bakar, Siti Nur Amira
    Moner, Nur Hanisah Mohd
    Aziz, Nurul Athirah Abdul
    TRANSACTIONS ON ENGINEERING TECHNOLOGIES, 2015, : 361 - 368
  • [7] Image quality based x-ray dose control in cardiac imaging
    Davies, Andrew G.
    Kengyelics, Stephen M.
    Gislason-Lee, Amber J.
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS XIII, 2015, 9399
  • [8] Dose and Image Quality Evaluation of a Low-Dose Slot-Scanning X-Ray System for Pediatric Orthopedic Studies
    Liu, Z.
    Hoerner, M.
    Lamoureux, R.
    Rill, L.
    Arreola, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3217 - 3218
  • [9] Fluorescent X-ray Scan Image Quality Prediction
    Peter B. Weichman
    Eugene M. Lavely
    Journal of Hardware and Systems Security, 2020, 4 (1) : 13 - 23
  • [10] Assessment of Absorbed Dose and Image Quality Using Cone Beam CT On An X-Ray Angiography System
    Supanich, M.
    Vanderhoek, M.
    MEDICAL PHYSICS, 2013, 40 (06)