Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK)

被引:73
|
作者
Nederveen, A [1 ]
Lagendijk, J [1 ]
Hofman, P [1 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiat Oncol, NL-3584 CX Utrecht, Netherlands
关键词
portal imaging; gold markers; position verification; detection algorithm;
D O I
10.1016/S0360-3016(00)00523-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In this study automatic detection of implanted gold markers in megavoltage portal images for on-line position verification was investigated, Methods and Materials: A detection method for fiducial gold markers, consisting of a marker extraction kernel (MEK), was developed. The detection success rate was determined for different markers using this MEK. The localization accuracy was investigated by measuring distances between markers, which were fixed on a perspex template. In order to generate images comparable to images of patients with implanted markers, this template was placed on the skin of patients before the start of the treatment, Portal images were taken of lateral prostate fields at 18 MV within 1-2 monitor units (MU). Results: The detection success rates for markers of 5 mm length and 1.2 and 1.4 mm diameter were 0.95 and 0.99 respectively when placed at the beam entry and 0.39 and 0.86 when placed at the beam exit. The localization accuracy appears to be better than 0.6 mm for all markers. Conclusion: Automatic marker detection with an acceptable accuracy at the start of a radiotherapy fraction is feasible, Further minimization of marker diameters may be achieved with the help of an a-Si flat panel imager and may increase the clinical acceptance of this technique. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1435 / 1442
页数:8
相关论文
共 7 条
  • [1] Automatic detection of fiducial markers in fluoroscopy images for on-line calibration
    Smith, L
    Pleasance, M
    Seeton, R
    Archip, N
    Rohling, R
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1521 - 1523
  • [2] Automatic Detection of Gold Fiducial Markers On MR Images Using the RASOR Technique
    Seevinck, P.
    van den Berg, C. A. T.
    Moerland, M. A.
    Philippens, M.
    Lagendijk, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 186 - 186
  • [3] Automatic marker detection and 3D position reconstruction using cine EPID images for SBRT verification
    Park, Sang-June
    Ionascu, Dan
    Hacker, Fred
    Mamon, Harvey
    Berbeco, Ross
    [J]. MEDICAL PHYSICS, 2009, 36 (10) : 4536 - 4546
  • [4] Daily 3D on-line setup verification and correction for 45 prostate patients using implanted gold markers
    Pasma, K. L.
    Leijser, V.
    Schimmel, E.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2030 - 2030
  • [5] Automatic determination of phylloquinone in vegetables and fruits using on-line photochemical reduction and fluorescence detection via solid phase extraction and flow injection
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Martín, J
    García, MD
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (01) : 280 - 285
  • [6] Automatic determination of phylloquinone in vegetables and fruits using on-line photochemical reduction and fluorescence detection via solid phase extraction and flow injection
    Tomás Pérez-Ruiz
    Carmen Martínez-Lozano
    Jesús Martín
    Maria Dolores García
    [J]. Analytical and Bioanalytical Chemistry, 2006, 384 : 280 - 285
  • [7] Direct automatic screening and individual determination of polycyclic aromatic hydrocarbons using supercritical fluid extraction coupled on-line with liquid chromatography and fluorimetric detection
    Zougagh, M
    Ríos, A
    Valcárcel, M
    [J]. ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) : 279 - 285