Quantitative Determination of Cyclosporine in Human Whole Blood by Ultra-Performance Liquid Chromatography with Triple Quadrupole Tandem Mass Spectrometry

被引:6
|
作者
Jung, Hyun Jin [1 ,2 ]
Gwon, Mi-Ri [1 ,2 ,3 ]
Park, Jeonghyeon [1 ,2 ]
Seo, Jeong Ju [1 ,2 ]
Seong, Sook Jin [1 ,2 ]
Kim, Eun Hee [4 ]
Suh, Soon Rim [5 ]
Jeong, Ji Yun [6 ]
Lee, Hae Won [1 ,2 ]
Yoon, Young-Ran [1 ,2 ,3 ]
机构
[1] Kyungpook Natl Univ, Grad Sch & Hosp, Dept Biomed Sci, Taegu 700721, South Korea
[2] Kyungpook Natl Univ, Grad Sch & Hosp, Clin Trial Ctr, Taegu 700721, South Korea
[3] Kyungpook Natl Univ, Grad Sch, KNU Biomed Convergence Program Creat Talent, Taegu 700842, South Korea
[4] Yeungnam Coll Sci & Technol, Sch Nursing, Taegu 705703, South Korea
[5] Kyungpook Natl Univ, Coll Nursing, Taegu 700422, South Korea
[6] Kyungpook Natl Univ, Sch Med, Dept Internal Med, Div Endocrinol & Metab, Taegu 700842, South Korea
基金
新加坡国家研究基金会;
关键词
Cyclosporine; UPLC-MS/MS; human whole blood; A CSA; EXTRACTION; EVEROLIMUS; UPLC; PHARMACOKINETICS; METABOLITES; TACROLIMUS; SIROLIMUS; QUANTIFICATION; BIOEQUIVALENCE;
D O I
10.2116/analsci.30.293
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cyclosporine is an immunosuppressant drug used in organ transplants or for the treatment of autoimmune diseases. We developed and validated a simple, sensitive, and specific method using UPLC-MS/MS to determine cyclosporine levels in human whole blood. MS/MS detection was performed in the positive electrospray ionization mode with multiple reaction monitoring. Cyclosporine was extracted from whole-blood samples using ascomycin as an internal standard. The mass transitions m/z 1203.49 -> 1185.53 and m/z 814.71 -> 796.67 were used to assay the analyte and IS. This method was validated with respect to linearity, specificity, accuracy, precision, recovery, and stability. The method exhibited a linear response from 10 to 1000 ng mL(-1) with correlation coefficient values >0.99. The precision and the accuracy values were within 15%, except at the lower limit of quatification (LLOQ). Cyclosporine was stable in whole blood with no evidence of degradation. This method was successfully applied to a pharmacokinetic study of cyclosporine in healthy volunteers following oral administration.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [1] Quantitative Determination of Cyclosporine in Human Whole Blood by Ultra-Performance Liquid Chromatography with Triple Quadrupole Tandem Mass Spectrometry
    Hyun Jin Jung
    Mi-Ri Gwon
    Jeonghyeon Park
    Jeong Ju Seo
    Sook Jin Seong
    Eun Hee Kim
    Soon Rim Suh
    Ji Yun Jeong
    Hae Won Lee
    Young-Ran Yoon
    [J]. Analytical Sciences, 2014, 30 : 293 - 298
  • [2] Drug Screening of Whole Blood by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Oiestad, Elisabeth Leere
    Johansen, Unni
    Oiestad, Ase Marit Leere
    Christophersen, Asbjorg Solberg
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (05) : 280 - 293
  • [3] Rapid and simultaneous determination of 22 constituents in Menispermi Rhizoma by ultra-performance liquid chromatography tandem triple quadrupole mass spectrometry
    Wei, Jinxia
    Cui, Kunna
    Du, Yueying
    Yu, Jia
    Jiang, Zhen
    Guo, Xingjie
    [J]. ANALYTICAL METHODS, 2017, 9 (20) : 3029 - 3038
  • [4] Determination of acetyl coenzyme A in human whole blood by ultra-performance liquid chromatography-mass spectrometry
    Speziale, Roberto
    Montesano, Camilla
    De Leonibus, Maria Lucia
    Bonelli, Fabio
    Fezzardi, Paola
    Beconi, Maria G.
    Monteagudo, Edith
    Elbaum, Daniel
    Orsatti, Laura
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1083 : 57 - 62
  • [5] Quantitative determination of mitiglinide in human plasma by ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Cai, Shuang
    Huo, Taoguang
    Feng, Wanyu
    Chen, Lingyun
    Qin, Feng
    Li, Famei
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 868 (1-2): : 83 - 87
  • [6] Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Bupropion and its Main Metabolites in Human Whole Blood
    Denooz, Raphael
    Mercerolle, Magali
    Lachatre, Gerard
    Charlier, Corinne
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2010, 34 (05) : 280 - 286
  • [7] Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
    Pan Lijing
    Chen Weiwei
    Yuan Minjia
    [J]. China Detergent & Cosmetics, 2023, 8 (04) : 30 - 36
  • [8] Quantitative Determination of Methohexital in Human Whole Blood by Liquid Chromatography Tandem Mass Spectrometry
    Zhang, Yi
    Zhang, Yunfeng
    Zhai, Chunfeng
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (06) : 521 - 525
  • [9] Determination of febuxostat in human plasma using ultra-performance liquid chromatography tandem mass spectrometry
    Lukram, Ojikumar
    Parmar, Shivaji
    Hande, Amit
    [J]. DRUG TESTING AND ANALYSIS, 2013, 5 (06) : 492 - 499
  • [10] Ultra-performance liquid chromatography/tandem mass spectrometry method for the determination of lercanidipine in human plasma
    Kalovidouris, Madgalene
    Michalea, Stavroula
    Robola, Nikoleta
    Koutsopoulou, Maria
    Panderi, Irene
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (19) : 2939 - 2946