In vivo study of blood flow in capillaries using μPIV method

被引:1
|
作者
Kurochkin, Maxim A. [1 ]
Fedosov, Ivan V. [1 ]
Tuchin, Valery V. [1 ]
机构
[1] Natl Res Saratov State Univ, Res Educ Inst Opt & Biophoton, Saratov 410012, Russia
关键词
intravital mu PIV; capillary blood flow velocity; image stabilization; VELOCITY-MEASUREMENT; FIELD; LDV;
D O I
10.1117/12.2051593
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A digital optical system for intravital capillaroscopy has been developed. It implements the particle image velocimetry (PIV) based approach for measurements of red blood cells velocity in individual capillary of human nailfold. We propose to use a digital real time stabilization technique for compensation of impact of involuntary movements of a finger on results of measurements. Image stabilization algorithm is based on correlation of feature tracking. The efficiency of designed image stabilization algorithm was experimentally demonstrated.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] In Vivo Measurements of Blood Flow in a Chicken Embryo Using Micro PIV Technique
    Yeo, Chang Sub
    Han, Kyu Yeon
    Lee, Sang Joon
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (04) : 314 - 319
  • [2] A method of estimating the rate of flow of blood through capillaries
    Harris, I
    LANCET, 1930, 1 : 963 - 963
  • [3] FLOW OF BLOOD IN CAPILLARIES
    BLOOR, MIG
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (03): : 443 - &
  • [4] Visualization of blood flow in aortic arch by using PIV method (in case of cannula insertion)
    Inamura, Takao
    Yanaoka, Hideki
    Yamazaki, Junichi
    Fukuda, Ikuo
    Minakawa, Masahito
    Fukui, Kozo
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2005, 71 (710): : 2385 - 2392
  • [5] Blood flow in capillaries by using porous media model
    Song, Fu-quan
    Xu, You-sheng
    Li, Hua-mei
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 (Suppl 1): : 46 - 49
  • [6] Blood flow in capillaries by using porous media model
    Fu-quan Song
    You-sheng Xu
    Hua-mei Li
    Journal of Central South University of Technology, 2007, 14 : 46 - 49
  • [7] X-ray PIV measurement of blood flow in deep vessels of a rat: An in vivo feasibility study
    Hanwook Park
    Eunseop Yeom
    Sang Joon Lee
    Scientific Reports, 6
  • [8] X-ray PIV measurement of blood flow in deep vessels of a rat: An in vivo feasibility study
    Park, Hanwook
    Yeom, Eunseop
    Lee, Sang Joon
    SCIENTIFIC REPORTS, 2016, 6
  • [9] Evaluation of the cell depleted layer of blood flow in vitro using confocal microscopic PIV method
    Lim, S. H.
    Lee, H.
    Lee, C. Y.
    Park, C. W.
    OPTICAL DIAGNOSTICS AND SENSING X: TOWARD POINT-OF-CARE DIAGNOSTICS, 2010, 7572
  • [10] BLOOD-FLOW IN CAPILLARIES
    LIN, KL
    LOPEZ, L
    HELLUMS, JD
    MICROVASCULAR RESEARCH, 1973, 5 (01) : 7 - 19