Fracture Loads of All-Ceramic Crowns under Wet and Dry Fatigue Conditions

被引:53
|
作者
Borges, Gilberto A. [1 ]
Caldas, Danilo [2 ]
Taskonak, Burak [3 ]
Yan, Jiahau [3 ]
Sobrinho, Lourenco Correr [4 ]
de Oliveira, Wildomar Jose [1 ]
机构
[1] Univ Uberaba, Dept Dent Mat & Restorat Dent, Uberaba, Brazil
[2] Pontificia Catolica Univ Parana, Dept Restorat Dent, Curitiba, Parana, Brazil
[3] Indiana Univ, Sch Dent, Div Dent Biomat, Dept Restorat Dent, Indianapolis, IN USA
[4] Univ Estadual Campinas, Dept Dent Mat, Piracicaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
Composite resin cement; resin-modified glass ionomer cement; ceramic system; luting agent; STRENGTH; RESISTANCE; BEHAVIOR;
D O I
10.1111/j.1532-849X.2009.00498.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to test the hypothesis that fracture loads of fatigued dental ceramic crowns are affected by testing environment and luting cement. Materials and Methods: One hundred and eighty crowns were prepared from bovine teeth using a lathe. Ceramic crowns were prepared from three types of ceramic systems: an alumina-infiltrated ceramic, a lithia-disilicate-based glass ceramic, and a leucite-reinforced ceramic. For each ceramic system, 30 crowns were cemented with a composite resin cement, and the remaining 30 with a resin-modified glass ionomer cement. For each ceramic system and cement, ten specimens were loaded to fracture without fatiguing. A second group (n = 10) was subjected to cyclic fatigue and fracture tested in a dry environment, and a third group (n = 10) was fatigued and fractured in distilled water. The results were statistically analyzed using one-way ANOVA and Tukey HSD test. Results: The fracture loads of ceramic crowns decreased significantly after cyclic fatigue loading (p <= 0.05); furthermore, fracture loads of crowns fatigued in a wet environment were statistically lower than those in a dry environment (p < 0.05). Crowns luted with a composite resin cement showed statistically greater fracture loads than those luted with a resin-modified glass ionomer cement (p <= 0.05). Conclusions: Fracture load of the three ceramic systems was found to be influenced by ceramic composition. Moreover, cement and fatigue condition influenced the fracture loads of the crown specimens evaluated in this study.
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [1] Comparison of the wet and dry fatigue properties of all-ceramic crowns.
    Correr Sobrinho, L.
    Knowles, J. C.
    Sinhoreti, M. A. C.
    Consani, S.
    Reges, R. V.
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : B123 - B123
  • [2] Probability of fracture of all-ceramic crowns
    Chai, J
    Takahashi, Y
    Sulaiman, F
    Chong, KH
    Lautenschlager, EP
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (05) : 420 - 424
  • [3] Fracture strength of all-ceramic crowns
    Sobrinho, LC
    Cattell, MJ
    Knowles, JC
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (10) : 555 - 559
  • [4] Fracture strength of all-ceramic crowns
    L. Correr Sobrinho
    M.J. Cattell
    J.C. Knowles
    [J]. Journal of Materials Science: Materials in Medicine, 1998, 9 : 555 - 559
  • [5] Comparison of the wet and dry fatigue properties of all ceramic crowns
    L. Correr Sobrinho
    R. H. Glover
    J. C. Knowles
    M. J. Cattell
    [J]. Journal of Materials Science: Materials in Medicine, 1998, 9 : 517 - 521
  • [6] Comparison of the wet and dry fatigue properties of all ceramic crowns
    Sobrinho, LC
    Glover, RH
    Knowles, JC
    Cattell, MJ
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (09) : 517 - 521
  • [7] Fracture load of all-ceramic computer crowns
    Lampe, K
    Luthy, H
    Mormann, WH
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1142 - 1142
  • [8] Fracture load of all-ceramic computer crowns
    Lampe, K
    Luthy, H
    Mormann, WH
    [J]. CAD/CIM IN AESTHETIC DENTISTRY, 1996, : 463 - 482
  • [9] Influence of Thermomechanical Fatigue Loading on the Fracture Resistance of All-ceramic Posterior Crowns
    Senyilmaz, Dilek Pinar
    Canay, Senay
    Heydecke, Guido
    Strub, Joerg Rudolf
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2010, 18 (02): : 50 - 54
  • [10] Fracture Mechanics Analysis of GI All-Ceramic Crowns
    Fan, Cheng
    [J]. ADVANCED ENGINEERING MATERIALS III, PTS 1-3, 2013, 750-752 : 529 - 532