Aptamer-based electrochemical biosensor for detection of adenosine triphosphate using a nanoporous gold platform

被引:43
|
作者
Kashefi-Kheyrabadi, Leila [1 ]
Mehrgardi, Masoud A. [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
Aptasensor; Aptamer; Adenosine triphosphate; Nanoporous gold electrode; 3; 4-Diaminobenzoic acid; LABEL-FREE; IMPEDANCE SPECTROSCOPY; ELECTRONIC DETECTION; DNA; REAGENTLESS; FABRICATION; SENSORS; BLOOD; OLIGONUCLEOTIDES; APTASENSOR;
D O I
10.1016/j.bioelechem.2013.05.005
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In spite of the promising applications of aptamers in the bioassays, the development of aptamer-based electrochemical biosensors with the improved limit of detection has remained a great challenge. A strategy for the amplification of signal, based on application of nanostructures as platforms for the construction of an electrochemical adenosine triphosphate (ATP) aptasensor, is introduced in the present manuscript. A sandwich assay is designed by immobilizing a fragment of aptamer on a nanoporous gold electrode (NPGE) and its association to second fragment in the presence of ATP. Consequently, 3, 4-diarninobenzoic acid (DABA), as a molecular reporter, is covalently attached to the amine-label of the second fragment, and the direct oxidation signal of DABA is followed as the analytical signal. The sensor can detect the concentrations of ATP as low as submicromolar scales. Furthermore, 3.2% decrease in signal is observed by keeping the aptasensor at 4 degrees C for a week in buffer solution, implying a desirable stability. Moreover, analog nucleotides, including GTP, UTP and CTP, do not show serious interferences and this sensor easily detects its target in deproteinized human blood plasma. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 50 条
  • [1] An Aptamer-based Amperometric Biosensor for Adenosine Triphosphate Detection Based on Coplanar Thin-film Gold Electrode
    Jiang Li-Ying
    Wang Fen-Fen
    Hu Jie
    Yue Bao-Lei
    Yan Yan-Xia
    Chen Qing-Hua
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (05) : 666 - 671
  • [2] Aptamer-based detection of adenosine triphosphate via qPCR
    Modh, Harshvardhan
    Witt, Martin
    Urmann, Katharina
    Lavrentieva, Antonina
    Segal, Ester
    Scheper, Thomas
    Walter, Johanna-Gabriela
    [J]. TALANTA, 2017, 172 : 199 - 205
  • [3] An efficient signal-on aptamer-based biosensor for adenosine triphosphate detection using graphene oxide both as an electrochemical and electrochemiluminescence signal indicator
    Huang, Xiang
    Li, Yuqin
    Zhang, Xiaoshan
    Zhang, Xin
    Chen, Yaowen
    Gao, Wenhua
    [J]. ANALYST, 2015, 140 (17) : 6015 - 6024
  • [4] An aptamer-based electrochemical biosensor for the detection of Salmonella
    Ma, Xiaoyuan
    Jiang, Yihui
    Jia, Fei
    Yu, Ye
    Chen, Jie
    Wang, Zhouping
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 98 : 94 - 98
  • [5] Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine
    Yan, Fangfang
    Wang, Fang
    Chen, Zilin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 1380 - 1385
  • [6] Nanoporous Gold for the Miniaturization of In Vivo Electrochemical Aptamer-Based Sensors
    Downs, Alex M.
    Gerson, Julian
    Hossain, M. Nur
    Ploense, Kyle
    Pham, Michael
    Kraatz, Heinz-Bernhard
    Kippin, Tod
    Plaxco, Kevin W.
    [J]. ACS SENSORS, 2021, 6 (06) : 2299 - 2306
  • [7] Aptamer-Based Electrochemical Biosensor for Interferon Gamma Detection
    Liu, Ying
    Tuleouva, Nazgul
    Ramanculov, Erlan
    Revzin, Alexander
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (19) : 8131 - 8136
  • [8] Aptamer-based biosensor for the electrochemical detection of arsenite in water
    Fuentes, Nicole Rivera
    Vega-Figueroa, Karlene
    Tato, Perla Cruz
    Nicolau, Eduardo
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [9] Split aptamer-based detection of adenosine triphosphate using surface enhanced Raman spectroscopy and two kinds of gold nanoparticles
    Chunyang Zhou
    Zhi Yu
    Weili Yu
    Huiwen Liu
    Hao Zhang
    Chunlei Guo
    [J]. Microchimica Acta, 2019, 186
  • [10] An aptamer-based fluorescence biosensor for multiplex detection using unmodified gold nanoparticles
    Luo, Fang
    Zheng, Lingyan
    Chen, Shanshan
    Cai, Qihong
    Lin, Zhenyu
    Qiu, Bin
    Chen, Guonan
    [J]. CHEMICAL COMMUNICATIONS, 2012, 48 (51) : 6387 - 6389