Outcome of adjustment for posterior corneal curvature in tonic intraocular lens calculation and selection

被引:28
|
作者
Goggin, Michael [1 ,2 ,3 ]
van Zyl, Lourens [1 ,2 ,3 ]
Caputo, Silvestro [1 ,2 ,3 ]
Esterman, Adrian [4 ,5 ]
机构
[1] South Australian Inst Ophthalmol, Adelaide, SA, Australia
[2] Univ Adelaide, Adelaide, SA, Australia
[3] Queen Elizabeth Hosp, Adelaide, SA, Australia
[4] Univ South Australia, Sansom Inst Hlth Serv Res, Adelaide, SA, Australia
[5] James Cook Univ, Australian Inst Hlth & Med Res, Smithfield, Australia
来源
关键词
ASTIGMATIC NEUTRALITY;
D O I
10.1016/j.jcrs.2016.10.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of the cylinder power choice and the astigmatic refractive outcome for toric intraocular lenses (IOLs), the cylinder power of which was calculated using the Goggin nomogram that allows for the likely effect of posterior corneal astigmatism. SETTING: The Queen Elizabeth Hospital, Adelaide, Australia. DESIGN: Observational case series. METHODS: The absolute value of the prediction error of the toric IOL cylinder power effect in consecutive eyes with preoperative anterior keratometric cylinder values of 1.0 diopter (D) or more was compared with the absolute value of the prediction error in a historical control group. The anteriorly measured keratometric cylinder values were altered by 2 coefficients of adjustment, one for with-the-rule eyes and one for against-the-rule eyes, before calculation of the IOL cylinder power to be implanted. In the controls, unadjusted keratometric cylinder values were used. RESULTS: The case-series group comprised 31 eyes (29 patients) and the control group, 65 eyes. The absolute error in prediction of the toric IOL cylinder power effect was reduced from a median of 0.45 D (95% confidence interval [CI], 0.33-0.58) in the controls to a median of 0.23 D (95% CI, 0.13-0.35) in the adjusted eyes (P = .004). CONCLUSION: Adjustment of toric IOL cylinder power by application of a coefficient of adjustment to anteriorly measured keratometric cylinder values based on the keratometric rule of the eye led to a clinically and statistically significant improvement in refractive astigmatic outcome. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:1441 / 1448
页数:8
相关论文
共 50 条
  • [1] Adjustment of Anterior Corneal Astigmatism Values to Incorporate the Likely Effect of Posterior Corneal Curvature for Toric Intraocular Lens Calculation
    Goggin, Michael
    Zamora-Alejo, Katherine
    Esterman, Adrian
    van Zyl, Lourens
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (02) : 98 - +
  • [2] Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation
    Leyland, M
    [J]. EYE, 2004, 18 (04) : 357 - 360
  • [3] Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation
    M Leyland
    [J]. Eye, 2004, 18 : 357 - 360
  • [4] Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method
    Kim, Mingue
    Eom, Youngsub
    Lee, Hwa
    Suh, Young-Woo
    Song, Jong Suk
    Kim, Hyo Myung
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (02) : 1016 - 1024
  • [5] Use of the Ratio of Posterior to Anterior Corneal Radii of Curvature to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method
    Eom, Youngsub
    Kim, Mingyu
    Lee, Hwa
    Suh, Young-Woo
    Song, Jong Suk
    Kim, Hyo Myung
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] OUTCOME OF ADJUSTMENT OF ANTERIOR CORNEAL ASTIGMATISM VALUES TO INCORPORATE THE LIKELY EFFECT OF POSTERIOR CORNEAL CURVATURE FOR TORIC IOL CALCULATION
    Goggin, Michael
    van Zyl, Lourens
    Caputo, Silvestro
    Esterman, Adrian
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 : 41 - 41
  • [7] Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation
    Preussner, Paul-Rolf
    Hoffmann, Peter
    Wahl, Jochen
    [J]. CURRENT EYE RESEARCH, 2015, 40 (08) : 809 - 814
  • [8] Effect of posterior corneal astigmatism on refractive outcomes after tonic intraocular lens implantation
    Zhang, Lijun
    Sy, Mary Ellen
    Mai, Harry
    Yu, Fei
    Hamilton, D. Rex
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01): : 84 - 89
  • [9] Accuracy of intraocular lens calculation formulas in cataract patients with steep corneal curvature
    Zhang, Chenguang
    Dai, Guangzheng
    Pazo, Emmanuel Eric
    Xu, Ling
    Wu, Xianwei
    Zhang, Hongda
    Lin, Tiezhu
    He, Wei
    [J]. PLOS ONE, 2020, 15 (11):
  • [10] Comparative Effect of corneal curvature on acurracy of Intraocular Lens Power Calculation in various fomulars
    Kim, Bo Hyuck
    Kim, Mee Kum
    Wee, Won Ryang
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)