Role of Contrast-Enhanced Ultrasound in the Follow-up of Kidney Transplant Patients

被引:9
|
作者
Korda, D. [1 ]
Deak, P. A. [1 ]
Kozma, V. [1 ]
Kiss, G. [1 ]
Doros, A. [1 ]
机构
[1] Semmelweis Univ, Dept Transplantat & Surg, Budapest, Hungary
关键词
RENAL-TRANSPLANTATION; EXPERIENCE;
D O I
10.1016/j.transproceed.2016.07.010
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Contrast-enhanced ultrasound combines the advantages of native ultrasound and other contrast-enhanced imaging modalities. In selected cases it can be preferable to computerized tomographic scan among kidney transplant recipients. Methods. We performed a retrospective study involving patients of Semmelweis University Department of Transplantation and Surgery who underwent contrast-enhanced ultrasound examination from 2011 to 2015. During this period, 251 examinations were performed, including 45 on kidney transplant patients. A Toshiba Aplio XU ultrasound device was used, and 1-1.5 mL contrast agent (Sonovue) was administered intravenously for each patient. The indications of these evaluations can be divided into 3 groups: characterization of circumscribed kidney lesions, control after radiofrequency ablation therapy, and examination of graft perfusion. Results. Fully 93% of the examinations were conclusive. In the 1st group of the 37 cases where tumor-suspect lesions were investigated, 13 examinations suggested the presence of a space-occupying lesion. Of those 13 cases, 2 patients had a negative biopsy, nephrectomy was performed in 11 cases, and histologic evaluation verified a tumor in 8 samples. In the 2nd group, the ablation control examination detected a residual tumor in none of the 6 cases. Finally, in 1 of the 2 grafts where the circulation was investigated, blood flow was satisfactory, and in the other it was low. Conclusions. The contrast-enhanced ultrasound examination was conclusive in most cases. The applied contrast material is not nephrotoxic, and the method uses nonionizing radiation. These features make contrast-enhanced ultrasound highly suitable for the examination of kidney transplant patients.
引用
收藏
页码:2544 / 2547
页数:4
相关论文
共 50 条
  • [1] Contrast-Enhanced Ultrasound Follow-Up for Acute Pyelonephritis Patients
    Boccatonda, Andrea
    Venerato, Stefano
    D'Ardes, Damiano
    Cocco, Giulio
    Schiavone, Cosima
    Vicari, Susanna
    [J]. HEALTHCARE, 2023, 11 (21)
  • [2] CONTRAST-ENHANCED ULTRASOUND FOR CHARACTERIZATION AND FOLLOW-UP OF RENAL LESIONS
    Bertelli, Elena
    Agostini, Simone
    Lanzi, Federico
    Masieri, Lorenzo
    Quattrone, Livia Eleonora
    Tosi, Nicola
    Serni, Sergio
    Menchi, Ilario
    [J]. JOURNAL OF UROLOGY, 2011, 185 (04): : E277 - E278
  • [3] CONTRAST-ENHANCED ULTRASOUND FOR CHARACTERIZATION AND FOLLOW-UP OF RENAL LESIONS
    Bertelli, E.
    Agostini, S.
    Lanzi, F.
    Quattrone, L. E.
    Giancane, S.
    Tosi, N.
    Masieri, L.
    Serni, S.
    Menchi, I
    [J]. EUROPEAN UROLOGY SUPPLEMENTS, 2011, 10 (02) : 168 - 168
  • [4] Contrast-enhanced ultrasound: a new method for TIPS follow-up
    Capucine Micol
    Julien Marsot
    Nawele Boublay
    Frank Pilleul
    Yves Berthezene
    Agnès Rode
    [J]. Abdominal Imaging, 2012, 37 : 252 - 260
  • [5] Contrast-enhanced ultrasound: a new method for TIPS follow-up
    Micol, Capucine
    Marsot, Julien
    Boublay, Nawele
    Pilleul, Frank
    Berthezene, Yves
    Rode, Agnes
    [J]. ABDOMINAL IMAGING, 2012, 37 (02): : 252 - 260
  • [6] CONTRAST-ENHANCED ULTRASOUND FOR CHARACTERIZATION AND FOLLOW-UP OF RENAL LESIONS
    Bertelli, Elena
    Lanzi, Federico
    Quattrone, Livia Eleonora
    Giannessi, Claudia
    Giancane, Saverio
    Masieri, Lorenzo
    Menchi, Ilario
    Agostini, Simone
    [J]. ANTICANCER RESEARCH, 2011, 31 (05) : 1922 - 1922
  • [7] The role of contrast-enhanced ultrasound imaging in the follow-up of patients post-endovascular aneurysm repair
    Jawad, Nadia
    Parker, Pamela
    Lakshminarayan, Raghuram
    [J]. ULTRASOUND, 2016, 24 (01) : 50 - 59
  • [8] Role of contrast-enhanced ultrasound in follow-up assessment after ablation for hepatocellular carcinoma
    Shu-Guang Zheng
    Hui-Xiong Xu
    Ming-De Lu
    Xiao-Yan Xie
    Zuo-Feng Xu
    Guang-Jian Liu
    Lin-Na Liu
    [J]. World Journal of Gastroenterology, 2013, (06) : 855 - 865
  • [9] Role of contrast-enhanced ultrasound in follow-up assessment after ablation for hepatocellular carcinoma
    Zheng, Shu-Guang
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Yan
    Xu, Zuo-Feng
    Liu, Guang-Jian
    Liu, Lin-Na
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (06) : 855 - 865
  • [10] Value of contrast-enhanced ultrasound for diagnosis and follow-up of renal artery stenosis in patients with chronic kidney disease
    Tianhui Li
    Yonghui Mao
    Ban Zhao
    Haitao Wang
    Junhong Ren
    Na Ma
    Siyu Wang
    [J]. Abdominal Radiology, 2022, 47 : 1853 - 1861