Three-dimensional fluorescence-enhanced optical tomography using a hand-held probe based imaging system

被引:31
|
作者
Ge, Jiajia [1 ]
Zhu, Banghe [1 ]
Regalado, Steven [1 ]
Godavarty, Anuradha [1 ]
机构
[1] Florida Int Univ, Dept Biomed Engn, Opt Imaging Lab, Miami, FL 33174 USA
关键词
fluorescence optical tomography; hand-held; optical tomography; fluorescence; phantoms;
D O I
10.1118/1.2940603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Hand-held based optical imaging systems are a recent development towards diagnostic imaging of breast cancer. To date, all the hand-held based optical imagers are used to perform only surface mapping and target localization, but are not capable of demonstrating tomographic imaging. Herein, a novel hand-held probe based optical imager is developed towards three-dimensional (3-D) optical tomography studies. The unique features of this optical imager, which primarily consists of a hand-held probe and an intensified charge coupled device detector, are its ability to; (i) image large tissue areas (5x10 sq. cm) in a single scan, (ii) perform simultaneous multiple point illumination and collection, thus reducing the overall imaging time; and (iii) adapt to varying tissue curvatures, from a flexible probe head design. Experimental studies are performed in the frequency domain on large slab phantoms (similar to 650 ml) using fluorescence target(s) under perfect uptake (1:0) contrast ratios, and varying target depths (1-2 cm) and X-Y locations. The effect of implementing simultaneous over sequential multiple point illumination towards 3-D tomography is experimentally demonstrated. The feasibility of 3-D optical tomography studies has been demonstrated for the first time using a hand-held based optical imager. Preliminary fluorescence-enhanced optical tomography studies are able to reconstruct 0.45 ml target(s) located at different target depths (1-2 cm). However, the depth recovery was limited as the actual target depth increased, since only reflectance measurements were acquired. Extensive tomography studies are currently carried out to determine the resolution and performance limits of the imager on flat and curved phantoms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3354 / 3363
页数:10
相关论文
共 50 条
  • [1] Three-dimensional fluorescence tomography of human breast tissues in vivo using a hand-held optical imager
    Erickson, Sarah J.
    Martinez, Sergio L.
    DeCerce, Joseph
    Romero, Adrian
    Caldera, Lizeth
    Godavarty, Anuradha
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05): : 1563 - 1579
  • [2] Fluorescence-enhanced imaging using a novel hand-held based optical imager: Phantom studies - art. no. 684809
    Ge, Jiajia
    Zhu, Banghe
    Regalado, Steven
    Godavarty, Anuradha
    [J]. ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VI, 2008, 6848 : 84809 - 84809
  • [3] Multi-projection based fluorescence optical tomography using a hand-held probe based optical imager
    Ge, Jiajia
    Erickson, Sarah J.
    Godavarty, Anuradha
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VIII, 2009, 7174
  • [4] Hand-held optoacoustic probe for three-dimensional imaging of human morphology and function
    Dean-Ben, X. Luis
    Razansky, Daniel
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [5] Three-dimensional Information Projection System Using a Hand-held Screen
    Hashimoto, Sunao
    Tan, Joo Kooi
    Kim, Hyoungseop
    Ishikawa, Seiji
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC), VOLS 1-6, 2008, : 1384 - 1388
  • [6] Fluorescence-enhanced three-dimensional lifetime imaging: a phantom study
    Roy, Ranadhir
    Godavarty, Anuradha
    Sevick-Muraca, Eva M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14): : 4155 - 4170
  • [7] Design and development of a hand-held optical probe toward fluorescence diagnostic imaging
    Jayachandran, Bhavani
    Ge, Jiajia
    Regalado, Steven
    Godavarty, Anuradha
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (05)
  • [8] Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System
    Ethan J. Speir
    C. Matthew Hawkins
    Michael J. Weiler
    Michael Briones
    Rachel Swerdlin
    Solomon Park
    J. Brandon Dixon
    [J]. Journal of Digital Imaging, 2019, 32 : 260 - 268
  • [9] Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System
    Speir, Ethan J.
    Hawkins, C. Matthew
    Weiler, Michael J.
    Briones, Michael
    Swerdlin, Rachel
    Park, Solomon
    Dixon, J. Brandon
    [J]. JOURNAL OF DIGITAL IMAGING, 2019, 32 (02) : 260 - 268
  • [10] Hand-held probe based optical imaging system towards breast cancer diagnosis
    Ge, Jiajia
    Jayachandran, Bhavani
    Regalado, Steven
    Zhu, Banghe
    Godavarty, Anuradha
    [J]. ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS V, 2007, 6430