Potential of magnetic resonance-guided focused ultrasound for intracranial hemorrhage: an in vitro feasibility study

被引:3
|
作者
Harnof, Sagi [1 ]
Hananel, Arik [2 ]
Zilby, Zion [3 ]
Kulbatski, Iris [4 ]
Hadani, Moshe [1 ]
Kassell, Neal [5 ]
机构
[1] Chaim Sheba Med Ctr, Dept Neurosurg, IL-52621 Tel Hashomer, Israel
[2] FUS Fdn, Charlottesville, VA USA
[3] NCI, Radiat Oncol Branch, NIH, Bethesda, MD 20892 USA
[4] Toronto Western Res Inst, Dept Genet & Dev, Toronto, ON M5T 2S8, Canada
[5] Univ Virginia, Dept Neurosurg, Charlottesville, VA USA
关键词
intracranial hemorrhage; magnetic resonance-guided focused ultrasound; noninvasive; stroke; thrombolysis; BRAIN; THROMBOLYSIS; SURGERY; ABLATION; SYSTEM; RABBIT;
D O I
10.1111/ijs.12051
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Intracranial hemorrhage has a mortality rate of up to 40-60% due to the lack of effective treatment. Magnetic resonance-guided focused ultrasound may offer a breakthrough noninvasive technology, by allowing accurate delivery of focused ultrasound, under the guidance of real-time magnetic resonance imaging. Aim The purpose of the current study was to optimize the acoustic parameters of magnetic resonance-guided focused ultrasound for effective clot liquefaction, in order to evaluate the feasibility of magnetic resonance-guided focused ultrasound for thrombolysis. Methods Body (11MHz) and brain (220kHz) magnetic resonance-guided focused ultrasound systems (InSightec Ltd, Tirat Carmel, Israel) were used to treat tube-like (4cc), round (10cc), and bulk (300cc) porcine blood clots in vitro, using burst sonications of one-second to five-seconds, a duty cycle of 5-50%, and peak acoustic powers between 600 and 1200W. Liquefied volumes were measured as hyperintense regions on T2-weighted magnetic resonance images for body unit sonications (duration of one-second, duty cycle of 10%, and power of 500-1200W). Liquefaction efficiency was calculated for brain unit sonications (duration of one-second, duty cycle of 10%, power of 600W, and burst length between 01ms and 100ms). Results Liquified lesion volume increased as power was raised, without a thermal rise. For brain unit sonications, a power setting of 600W and ultrashort sonications (burst length between 01 and 10ms) resulted in liquefaction efficacy above 50%, while longer burst duration yielded lower efficacy. Conclusions These results demonstrate the feasibility of obtaining reproducible, rapid, efficient, and accurate blood clot lysis using the magnetic resonance-guided focused ultrasound system. Further in vivo studies are needed to validate the feasibility of magnetic resonance-guided focused ultrasound as a treatment modality for intracranial hemorrhage.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 50 条
  • [1] Potential of Magnetic Resonance-guided Focused Ultrasound for Intracranial Hemorrhage: An In Vivo Feasibility Study
    Harnof, Sagi
    Zibly, Zion
    Hananel, Arik
    Monteith, Stephen
    Grinfeld, Javier
    Schiff, Gilat
    Kulbatski, Iris
    Kassell, Neal
    [J]. JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (06): : 1585 - 1591
  • [2] Potential intracranial applications of magnetic resonance-guided focused ultrasound surgery
    Monteith, Stephen
    Sheehan, Jason
    Medel, Ricky
    Wintermark, Max
    Eames, Matthew
    Snell, John
    Kassell, Neal F.
    Elias, W. Jeff
    [J]. JOURNAL OF NEUROSURGERY, 2013, 118 (02) : 215 - 221
  • [3] Intracranial Applications of Magnetic Resonance-guided Focused Ultrasound
    Nir Lipsman
    Todd G. Mainprize
    Michael L. Schwartz
    Kullervo Hynynen
    Andres M. Lozano
    [J]. Neurotherapeutics, 2014, 11 : 593 - 605
  • [4] Intracranial Applications of Magnetic Resonance-guided Focused Ultrasound
    Lipsman, Nir
    Mainprize, Todd G.
    Schwartz, Michael L.
    Hynynen, Kullervo
    Lozano, Andres M.
    [J]. NEUROTHERAPEUTICS, 2014, 11 (03) : 593 - 605
  • [5] Magnetic resonance-guided focused ultrasound
    Albuquerque, Felipe C.
    [J]. NEUROSURGICAL FOCUS, 2013, 34 (05)
  • [6] Magnetic Resonance-Guided Focused Ultrasound Surgery
    Al Hilli, Mariam M.
    Stewart, Elizabeth A.
    [J]. SEMINARS IN REPRODUCTIVE MEDICINE, 2010, 28 (03) : 241 - 248
  • [7] Magnetic resonance-guided focused ultrasound surgery
    Hudson, Susan B. A.
    Stewart, Elizabeth A.
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 2008, 51 (01): : 159 - 166
  • [8] Transcranial magnetic resonance-guided focused ultrasound for temporal lobe epilepsy: a laboratory feasibility study
    Monteith, Stephen
    Snell, John
    Eames, Mathew
    Kassel, Neal F.
    Kelly, Edward
    Gwinn, Ryder
    [J]. JOURNAL OF NEUROSURGERY, 2016, 125 (06) : 1557 - 1564
  • [9] Magnetic resonance-guided focused ultrasound and essential tremor
    Gallay, Marc
    Jeanmonod, Daniel
    [J]. NEUROSURGICAL FOCUS, 2018, 45 (01)
  • [10] Magnetic resonance-guided focused ultrasound for the treatment of tremor
    Yamamoto, Kazuaki
    Sarica, Can
    Loh, Aaron
    Vetkas, Artur
    Samuel, Nardin
    Milano, Vanessa
    Zemmar, Ajmal
    Germann, Juergen
    Cheyuo, Cletus
    Boutet, Alexandre
    Elias, Gavin J. B.
    Ito, Hisashi
    Taira, Takaomi
    Lozano, Andres M.
    [J]. EXPERT REVIEW OF NEUROTHERAPEUTICS, 2022, 22 (10) : 849 - 861