Performance analysis of a micro-combined heating and power system with PEM fuel cell as a prime mover for a typical household in North China

被引:60
|
作者
Chang, Huawei [1 ]
Xu, Xiangxiang [1 ]
Shen, Jun [1 ]
Shu, Shuiming [1 ]
Tu, Zhengkai [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Hubei, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Combined heating and power; PEM fuel cell; Thermal-load-following; Thermal performance; Economic performance; ALTERNATIVE OPERATING STRATEGY; CHP SYSTEM; RESIDENTIAL APPLICATION; COGENERATION SYSTEMS; ENERGY; CCHP; MODEL; OPTIMIZATION; DESIGN; LIFE;
D O I
10.1016/j.ijhydene.2019.07.183
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Proton exchange membrane (PEM) fuel cells produce a large amount of waste heat while generating electricity through electrochemical reactions, making them suitable for driving combined heating and power (CHP) systems. According to the hourly thermal and electric loads in a typical North China household, a 2-kW PEM fuel cell-based micro-CHP system with a lithium-ion battery energy storage system is proposed in this paper. The thermal and economic performances of the micro-CHP system with a lithium-ion battery (CHPWB) and a CHP system without a lithium-ion battery (CHPWOB) are comparatively analyzed by developing a thermal and economic performance analysis model on the MATLAB/Simulink platform. The thermal-load-following strategy is adopted during the design and simulation process. The results indicate that the storage capacity of the lithium-ion battery decreases by 6.6% after one cycle. The lithium-ion battery can be charged by the fuel cell stack during off-peak hours or using commercial electricity, and the charging cycle of the system is one week long. The average total efficiency of the CHPWB system can reach 81.24% with considering the energy loss in each conversion process, which is 11.02% higher than that of the CHPWOB system. The daily hydrogen consumption of the CHPWB system can be reduced by 14.47% compared with the CHPWOB system under the same operating conditions, and the average daily costs can be reduced by 8.4% and 9.5% when the lifespan is 10 and 15 years, respectively. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:24965 / 24976
页数:12
相关论文
共 50 条
  • [1] Performance analysis of a combined cooling, heating and power system with PEM fuel cell as a prime mover
    Chahartaghi, Mahmood
    Kharkeshi, Behrad Alizadeh
    [J]. APPLIED THERMAL ENGINEERING, 2018, 128 : 805 - 817
  • [2] Investigation of micro-combined heat and power application of PEM fuel cell systems
    Budak, Yagmur
    Devrim, Yilser
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 160 : 486 - 494
  • [3] Sizing the prime mover of a residential micro-combined cooling heating and power (CCHP) system by multi-criteria sizing method for different climates
    Ebrahimi, Masood
    Keshavarz, Ali
    [J]. ENERGY, 2013, 54 : 291 - 301
  • [4] THERMODYNAMIC PERFORMANCE FOR THE SOLAR COLLECTOR OF A MICRO-COMBINED COOLING, HEATING AND POWER SYSTEM
    Paraschiv, Spiru
    Ion, Ion V.
    Paraschiv, Lizica Simona
    [J]. ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2011, 10 (09): : 1311 - 1317
  • [5] Optimal operation of a micro-combined cooling, heating and power system
    Kong, Xiang-Qiang
    Wang, Ru-Zhu
    Li, Ying
    Huang, Xing-Hua
    [J]. Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2008, 42 (03): : 365 - 369
  • [6] Biogas-fueled flame fuel cell for micro-combined heat and power system
    Zeng, Hongyu
    Wang, Yuqing
    Shi, Yixiang
    Cai, Ningsheng
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 701 - 707
  • [7] Performance evaluation of a micro-combined cooling, heating and power system based on structural theory of thermoeconomics
    Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    不详
    [J]. Kung Cheng Je Wu Li Hsueh Pao, 2008, 5 (731-736): : 731 - 736
  • [8] Evaluation of desiccant wheel and prime mover as combined cooling, heating, and power system
    Korouyeh, M. Mohammadian
    Saidi, M. H.
    Najafi, M.
    Aghanajafi, C.
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2019, 16 (03) : 256 - 268
  • [9] Emission and economic performance assessment of a solid oxide fuel cell micro-combined heat and power system in a domestic building
    Elmer, Theo
    Worall, Mark
    Wu, Shenyi
    Riffat, Saffa B.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 1082 - 1089
  • [10] Technical performance analysis of a micro-combined cooling, heating and power system based on solar energy and high temperature PEMFC
    Chang, Huawei
    Duan, Chen
    Xu, Xiangxiang
    Pei, Houchang
    Shu, Shuiming
    Tu, Zhengkai
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (38) : 21080 - 21089